Cargando…
Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol
PURPOSE: This study proposed a generative adversarial network (GAN) model for T2-weighted image (WI) synthesis from proton density (PD)-WI in a temporomandibular joint (TMJ) magnetic resonance imaging (MRI) protocol. MATERIALS AND METHODS: From January to November 2019, MRI scans for TMJ were review...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807788/ https://www.ncbi.nlm.nih.gov/pubmed/36605858 http://dx.doi.org/10.5624/isd.20220125 |
_version_ | 1784862787805118464 |
---|---|
author | Lee, Chena Ha, Eun-Gyu Choi, Yoon Joo Jeon, Kug Jin Han, Sang-Sun |
author_facet | Lee, Chena Ha, Eun-Gyu Choi, Yoon Joo Jeon, Kug Jin Han, Sang-Sun |
author_sort | Lee, Chena |
collection | PubMed |
description | PURPOSE: This study proposed a generative adversarial network (GAN) model for T2-weighted image (WI) synthesis from proton density (PD)-WI in a temporomandibular joint (TMJ) magnetic resonance imaging (MRI) protocol. MATERIALS AND METHODS: From January to November 2019, MRI scans for TMJ were reviewed and 308 imaging sets were collected. For training, 277 pairs of PD- and T2-WI sagittal TMJ images were used. Transfer learning of the pix2pix GAN model was utilized to generate T2-WI from PD-WI. Model performance was evaluated with the structural similarity index map (SSIM) and peak signal-to-noise ratio (PSNR) indices for 31 predicted T2-WI (pT2). The disc position was clinically diagnosed as anterior disc displacement with or without reduction, and joint effusion as present or absent. The true T2-WI-based diagnosis was regarded as the gold standard, to which pT2-based diagnoses were compared using Cohen’s ĸ coefficient. RESULTS: The mean SSIM and PSNR values were 0.4781(±0.0522) and 21.30(±1.51) dB, respectively. The pT2 protocol showed almost perfect agreement (ĸ=0.81) with the gold standard for disc position. The number of discordant cases was higher for normal disc position (17%) than for anterior displacement with reduction (2%) or without reduction (10%). The effusion diagnosis also showed almost perfect agreement (ĸ=0.88), with higher concordance for the presence (85%) than for the absence (77%) of effusion. CONCLUSION: The application of pT2 images for a TMJ MRI protocol useful for diagnosis, although the image quality of pT2 was not fully satisfactory. Further research is expected to enhance pT2 quality. |
format | Online Article Text |
id | pubmed-9807788 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-98077882023-01-04 Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol Lee, Chena Ha, Eun-Gyu Choi, Yoon Joo Jeon, Kug Jin Han, Sang-Sun Imaging Sci Dent Original Article PURPOSE: This study proposed a generative adversarial network (GAN) model for T2-weighted image (WI) synthesis from proton density (PD)-WI in a temporomandibular joint (TMJ) magnetic resonance imaging (MRI) protocol. MATERIALS AND METHODS: From January to November 2019, MRI scans for TMJ were reviewed and 308 imaging sets were collected. For training, 277 pairs of PD- and T2-WI sagittal TMJ images were used. Transfer learning of the pix2pix GAN model was utilized to generate T2-WI from PD-WI. Model performance was evaluated with the structural similarity index map (SSIM) and peak signal-to-noise ratio (PSNR) indices for 31 predicted T2-WI (pT2). The disc position was clinically diagnosed as anterior disc displacement with or without reduction, and joint effusion as present or absent. The true T2-WI-based diagnosis was regarded as the gold standard, to which pT2-based diagnoses were compared using Cohen’s ĸ coefficient. RESULTS: The mean SSIM and PSNR values were 0.4781(±0.0522) and 21.30(±1.51) dB, respectively. The pT2 protocol showed almost perfect agreement (ĸ=0.81) with the gold standard for disc position. The number of discordant cases was higher for normal disc position (17%) than for anterior displacement with reduction (2%) or without reduction (10%). The effusion diagnosis also showed almost perfect agreement (ĸ=0.88), with higher concordance for the presence (85%) than for the absence (77%) of effusion. CONCLUSION: The application of pT2 images for a TMJ MRI protocol useful for diagnosis, although the image quality of pT2 was not fully satisfactory. Further research is expected to enhance pT2 quality. Korean Academy of Oral and Maxillofacial Radiology 2022-12 2022-10-12 /pmc/articles/PMC9807788/ /pubmed/36605858 http://dx.doi.org/10.5624/isd.20220125 Text en Copyright © 2022 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0 (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Chena Ha, Eun-Gyu Choi, Yoon Joo Jeon, Kug Jin Han, Sang-Sun Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
title | Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
title_full | Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
title_fullStr | Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
title_full_unstemmed | Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
title_short | Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
title_sort | synthesis of t2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807788/ https://www.ncbi.nlm.nih.gov/pubmed/36605858 http://dx.doi.org/10.5624/isd.20220125 |
work_keys_str_mv | AT leechena synthesisoft2weightedimagesfromprotondensityimagesusingagenerativeadversarialnetworkinatemporomandibularjointmagneticresonanceimagingprotocol AT haeungyu synthesisoft2weightedimagesfromprotondensityimagesusingagenerativeadversarialnetworkinatemporomandibularjointmagneticresonanceimagingprotocol AT choiyoonjoo synthesisoft2weightedimagesfromprotondensityimagesusingagenerativeadversarialnetworkinatemporomandibularjointmagneticresonanceimagingprotocol AT jeonkugjin synthesisoft2weightedimagesfromprotondensityimagesusingagenerativeadversarialnetworkinatemporomandibularjointmagneticresonanceimagingprotocol AT hansangsun synthesisoft2weightedimagesfromprotondensityimagesusingagenerativeadversarialnetworkinatemporomandibularjointmagneticresonanceimagingprotocol |