Cargando…

Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model

Introduction: Direct quantification of hemodynamic factors applied to a cerebral aneurysm (CA) remains inaccessible due to the lack of technologies to measure the flow field within an aneurysm precisely. This study aimed to develop an in vitro validated 3D in silico patient-specific internal carotid...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Hang, Yang, Zifeng, Johnson, Mark, Bramlage, Luke, Ludwig, Bryan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810024/
https://www.ncbi.nlm.nih.gov/pubmed/36605897
http://dx.doi.org/10.3389/fphys.2022.1024590
_version_ 1784863239719354368
author Yi, Hang
Yang, Zifeng
Johnson, Mark
Bramlage, Luke
Ludwig, Bryan
author_facet Yi, Hang
Yang, Zifeng
Johnson, Mark
Bramlage, Luke
Ludwig, Bryan
author_sort Yi, Hang
collection PubMed
description Introduction: Direct quantification of hemodynamic factors applied to a cerebral aneurysm (CA) remains inaccessible due to the lack of technologies to measure the flow field within an aneurysm precisely. This study aimed to develop an in vitro validated 3D in silico patient-specific internal carotid artery sidewall aneurysm (ICASA) model which can be used to investigate hemodynamic factors on the CA pathophysiology. Methods: The validated ICASA model was developed by quantifying and comparing the flow field using particle image velocimetry (PIV) measurements and computational fluid dynamics (CFD) simulations. Specifically, the flow field characteristics, i.e., blood flowrates, normalized velocity profiles, flow streamlines, and vortex locations, have been compared at representative time instants in a cardiac pulsatile period in two designated regions of the ICASA model, respectively. One region is in the internal carotid artery (ICA) inlet close to the aneurysm sac, the other is across the middle of the aneurysmal sac. Results and Discussion: The results indicated that the developed computational fluid dynamics model presents good agreements with the results from the parallel particle image velocimetry and flowrate measurements, with relative differences smaller than 0.33% in volumetric flow rate in the ICA and relative errors smaller than 9.52% in averaged velocities in the complex aneurysmal sac. However, small differences between CFD and PIV in the near wall regions were observed due to the factors of slight differences in the 3D printed model, light reflection and refraction near arterial walls, and flow waveform uncertainties. The validated model not only can be further employed to investigate hemodynamic factors on the cerebral aneurysm pathophysiology statistically, but also provides a typical model and guidance for other professionals to evaluate the hemodynamic effects on cerebral aneurysms.
format Online
Article
Text
id pubmed-9810024
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98100242023-01-04 Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model Yi, Hang Yang, Zifeng Johnson, Mark Bramlage, Luke Ludwig, Bryan Front Physiol Physiology Introduction: Direct quantification of hemodynamic factors applied to a cerebral aneurysm (CA) remains inaccessible due to the lack of technologies to measure the flow field within an aneurysm precisely. This study aimed to develop an in vitro validated 3D in silico patient-specific internal carotid artery sidewall aneurysm (ICASA) model which can be used to investigate hemodynamic factors on the CA pathophysiology. Methods: The validated ICASA model was developed by quantifying and comparing the flow field using particle image velocimetry (PIV) measurements and computational fluid dynamics (CFD) simulations. Specifically, the flow field characteristics, i.e., blood flowrates, normalized velocity profiles, flow streamlines, and vortex locations, have been compared at representative time instants in a cardiac pulsatile period in two designated regions of the ICASA model, respectively. One region is in the internal carotid artery (ICA) inlet close to the aneurysm sac, the other is across the middle of the aneurysmal sac. Results and Discussion: The results indicated that the developed computational fluid dynamics model presents good agreements with the results from the parallel particle image velocimetry and flowrate measurements, with relative differences smaller than 0.33% in volumetric flow rate in the ICA and relative errors smaller than 9.52% in averaged velocities in the complex aneurysmal sac. However, small differences between CFD and PIV in the near wall regions were observed due to the factors of slight differences in the 3D printed model, light reflection and refraction near arterial walls, and flow waveform uncertainties. The validated model not only can be further employed to investigate hemodynamic factors on the cerebral aneurysm pathophysiology statistically, but also provides a typical model and guidance for other professionals to evaluate the hemodynamic effects on cerebral aneurysms. Frontiers Media S.A. 2022-12-20 /pmc/articles/PMC9810024/ /pubmed/36605897 http://dx.doi.org/10.3389/fphys.2022.1024590 Text en Copyright © 2022 Yi, Yang, Johnson, Bramlage and Ludwig. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Yi, Hang
Yang, Zifeng
Johnson, Mark
Bramlage, Luke
Ludwig, Bryan
Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
title Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
title_full Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
title_fullStr Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
title_full_unstemmed Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
title_short Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
title_sort developing an in vitro validated 3d in silico internal carotid artery sidewall aneurysm model
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810024/
https://www.ncbi.nlm.nih.gov/pubmed/36605897
http://dx.doi.org/10.3389/fphys.2022.1024590
work_keys_str_mv AT yihang developinganinvitrovalidated3dinsilicointernalcarotidarterysidewallaneurysmmodel
AT yangzifeng developinganinvitrovalidated3dinsilicointernalcarotidarterysidewallaneurysmmodel
AT johnsonmark developinganinvitrovalidated3dinsilicointernalcarotidarterysidewallaneurysmmodel
AT bramlageluke developinganinvitrovalidated3dinsilicointernalcarotidarterysidewallaneurysmmodel
AT ludwigbryan developinganinvitrovalidated3dinsilicointernalcarotidarterysidewallaneurysmmodel