Cargando…

A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets

OBJECTIVE: To study the relationship of plan quality indices with the number and volume of target for 5 to 10 brain metastases treated with LINAC-based Single Isocenter Multiple Target (SIMT) Stereotactic radiosurgery (SRS) planning and to determine the maximum volume of spherical targets treated wi...

Descripción completa

Detalles Bibliográficos
Autores principales: V, Hemalatha Priyadarsini, R, Murali, N, Arunai Nambi Raj, S, Saravanan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: West Asia Organization for Cancer Prevention 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810297/
https://www.ncbi.nlm.nih.gov/pubmed/36172673
http://dx.doi.org/10.31557/APJCP.2022.23.9.3103
_version_ 1784863281756766208
author V, Hemalatha Priyadarsini
R, Murali
N, Arunai Nambi Raj
S, Saravanan
author_facet V, Hemalatha Priyadarsini
R, Murali
N, Arunai Nambi Raj
S, Saravanan
author_sort V, Hemalatha Priyadarsini
collection PubMed
description OBJECTIVE: To study the relationship of plan quality indices with the number and volume of target for 5 to 10 brain metastases treated with LINAC-based Single Isocenter Multiple Target (SIMT) Stereotactic radiosurgery (SRS) planning and to determine the maximum volume of spherical targets treated without exceeding the normal tissue tolerances. METHODS: Spherical targets of 5 to 10 numbers per plan, with individual target volumes ranging from 0.025 cc to 11.5 cc, were simulated with randomly drawn planning target volumes (PTVs) within the brain. SIMT SRS plans were generated for the 21 Gy prescription dose with a 6 MV Flattening Filter Free photon beam. Target coverage, organ at risk sparing, plan quality indices, R(50%), and gradient measure were studied. Mean brain dose, V(12) for Brain minus PTV (BmP), V(10), V(12), V(15), V(18), V(20), and V(24) for brain volume were evaluated. Equations relating the gradient index, mean brain dose, and V(12) (BmP) to the given number and volume of the targets were constructed. RESULTS: PTV coverage D(98) was 98.77 ± 1.37 %. The mean CI(RTOG), Q(RTOG), HI(RTOG), CI(P), GI, and R(50%) of the individual targets were 1.02 ± 0.08, 0.94 ± 0.02, 1.49 ± 0.11, 0.91 ± 0.06, 4.74 ± 2.3, and 4.95 ± 2.67, respectively. The gradient measure achieved was in the range of 0.49 to 1.35 cm. The mean brain dose was in the range of 1.62 to 6.69 Gy. The mean V(12) (BmP) per target obtained was 3.85 ± 2.83 cc. CONCLUSION: Equations relating the number and volume of targets to the gradient measure, mean brain dose, V(12) (BmP), and V(10-24) can serve as a baseline for multiple brain metastases SIMT planning. The target volume for 5, 6, 7, 8, 9, and 10 targets that can be treated without exceeding V(12) (BmP) is 6, 5, 4.7, 4, 3.7, and 3.4 cc, respectively, for the 21 Gy prescription dose.
format Online
Article
Text
id pubmed-9810297
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher West Asia Organization for Cancer Prevention
record_format MEDLINE/PubMed
spelling pubmed-98102972023-01-06 A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets V, Hemalatha Priyadarsini R, Murali N, Arunai Nambi Raj S, Saravanan Asian Pac J Cancer Prev Research Article OBJECTIVE: To study the relationship of plan quality indices with the number and volume of target for 5 to 10 brain metastases treated with LINAC-based Single Isocenter Multiple Target (SIMT) Stereotactic radiosurgery (SRS) planning and to determine the maximum volume of spherical targets treated without exceeding the normal tissue tolerances. METHODS: Spherical targets of 5 to 10 numbers per plan, with individual target volumes ranging from 0.025 cc to 11.5 cc, were simulated with randomly drawn planning target volumes (PTVs) within the brain. SIMT SRS plans were generated for the 21 Gy prescription dose with a 6 MV Flattening Filter Free photon beam. Target coverage, organ at risk sparing, plan quality indices, R(50%), and gradient measure were studied. Mean brain dose, V(12) for Brain minus PTV (BmP), V(10), V(12), V(15), V(18), V(20), and V(24) for brain volume were evaluated. Equations relating the gradient index, mean brain dose, and V(12) (BmP) to the given number and volume of the targets were constructed. RESULTS: PTV coverage D(98) was 98.77 ± 1.37 %. The mean CI(RTOG), Q(RTOG), HI(RTOG), CI(P), GI, and R(50%) of the individual targets were 1.02 ± 0.08, 0.94 ± 0.02, 1.49 ± 0.11, 0.91 ± 0.06, 4.74 ± 2.3, and 4.95 ± 2.67, respectively. The gradient measure achieved was in the range of 0.49 to 1.35 cm. The mean brain dose was in the range of 1.62 to 6.69 Gy. The mean V(12) (BmP) per target obtained was 3.85 ± 2.83 cc. CONCLUSION: Equations relating the number and volume of targets to the gradient measure, mean brain dose, V(12) (BmP), and V(10-24) can serve as a baseline for multiple brain metastases SIMT planning. The target volume for 5, 6, 7, 8, 9, and 10 targets that can be treated without exceeding V(12) (BmP) is 6, 5, 4.7, 4, 3.7, and 3.4 cc, respectively, for the 21 Gy prescription dose. West Asia Organization for Cancer Prevention 2022-09 /pmc/articles/PMC9810297/ /pubmed/36172673 http://dx.doi.org/10.31557/APJCP.2022.23.9.3103 Text en https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-Non Commercial 4.0 International License. https://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Research Article
V, Hemalatha Priyadarsini
R, Murali
N, Arunai Nambi Raj
S, Saravanan
A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets
title A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets
title_full A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets
title_fullStr A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets
title_full_unstemmed A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets
title_short A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets
title_sort comprehensive evaluation of single isocenter multiple target srs plans and the analytical relationship between plan quality indices with the number and volume of targets
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810297/
https://www.ncbi.nlm.nih.gov/pubmed/36172673
http://dx.doi.org/10.31557/APJCP.2022.23.9.3103
work_keys_str_mv AT vhemalathapriyadarsini acomprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT rmurali acomprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT narunainambiraj acomprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT ssaravanan acomprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT vhemalathapriyadarsini comprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT rmurali comprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT narunainambiraj comprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets
AT ssaravanan comprehensiveevaluationofsingleisocentermultipletargetsrsplansandtheanalyticalrelationshipbetweenplanqualityindiceswiththenumberandvolumeoftargets