Cargando…
Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs
This study aimed at investigating differences in heat generation and bone architecture following four different implant site preparation techniques: compressive osteotomes, conventional drills, osseodensification (OD mode with osseodensification drills), and piezoelectric systems. Porcine rib bones...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Nature Singapore
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810586/ https://www.ncbi.nlm.nih.gov/pubmed/35852778 http://dx.doi.org/10.1007/s10266-022-00730-8 |
_version_ | 1784863339655987200 |
---|---|
author | Bhargava, Nishith Perrotti, Vittoria Caponio, Vito Carlo Alberto Matsubara, Victor Haruo Patalwala, Diana Quaranta, Alessandro |
author_facet | Bhargava, Nishith Perrotti, Vittoria Caponio, Vito Carlo Alberto Matsubara, Victor Haruo Patalwala, Diana Quaranta, Alessandro |
author_sort | Bhargava, Nishith |
collection | PubMed |
description | This study aimed at investigating differences in heat generation and bone architecture following four different implant site preparation techniques: compressive osteotomes, conventional drills, osseodensification (OD mode with osseodensification drills), and piezoelectric systems. Porcine rib bones were used as a model for implant surgery. Thermocouples were employed to measure temperature changes, and micro-CT to assess the bone architecture. The primary stability and insertion torque values of the implants placed in the differently prepared sites were assessed. The temperature changes were higher with Piezo. The average primary stability using the ISQ scale was the greatest for drills (76.17 ± 0.90) and the lowest for osteotomes (71.50 ± 11.09). Insertion torque was significantly higher with the osseodensification method (71.67 ± 7.99 Ncm) in comparison to drills, osteotomes, and piezo. Osteotomes showed the highest bone to implant contact percentage (39.83 ± 3.14%) and average trabecular number (2.02 ± 0.21 per mm), while drills exhibited the lowest (30.73 ± 1.65%; 1.37 ± 0.34 per mm). Total implant site bone volume was the highest with osseodensification (37.26 ± 4.13mm(3)) and the lowest for osteotomes (33.84 ± 3.84mm(3)). Statistical analysis showed a high primary stability and decrease in temperature during implant site preparation with osseodensification technique. The results support the use of osseodensification technique for implant site preparation. |
format | Online Article Text |
id | pubmed-9810586 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Nature Singapore |
record_format | MEDLINE/PubMed |
spelling | pubmed-98105862023-01-05 Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs Bhargava, Nishith Perrotti, Vittoria Caponio, Vito Carlo Alberto Matsubara, Victor Haruo Patalwala, Diana Quaranta, Alessandro Odontology Original Article This study aimed at investigating differences in heat generation and bone architecture following four different implant site preparation techniques: compressive osteotomes, conventional drills, osseodensification (OD mode with osseodensification drills), and piezoelectric systems. Porcine rib bones were used as a model for implant surgery. Thermocouples were employed to measure temperature changes, and micro-CT to assess the bone architecture. The primary stability and insertion torque values of the implants placed in the differently prepared sites were assessed. The temperature changes were higher with Piezo. The average primary stability using the ISQ scale was the greatest for drills (76.17 ± 0.90) and the lowest for osteotomes (71.50 ± 11.09). Insertion torque was significantly higher with the osseodensification method (71.67 ± 7.99 Ncm) in comparison to drills, osteotomes, and piezo. Osteotomes showed the highest bone to implant contact percentage (39.83 ± 3.14%) and average trabecular number (2.02 ± 0.21 per mm), while drills exhibited the lowest (30.73 ± 1.65%; 1.37 ± 0.34 per mm). Total implant site bone volume was the highest with osseodensification (37.26 ± 4.13mm(3)) and the lowest for osteotomes (33.84 ± 3.84mm(3)). Statistical analysis showed a high primary stability and decrease in temperature during implant site preparation with osseodensification technique. The results support the use of osseodensification technique for implant site preparation. Springer Nature Singapore 2022-07-19 2023 /pmc/articles/PMC9810586/ /pubmed/35852778 http://dx.doi.org/10.1007/s10266-022-00730-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Bhargava, Nishith Perrotti, Vittoria Caponio, Vito Carlo Alberto Matsubara, Victor Haruo Patalwala, Diana Quaranta, Alessandro Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
title | Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
title_full | Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
title_fullStr | Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
title_full_unstemmed | Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
title_short | Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
title_sort | comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810586/ https://www.ncbi.nlm.nih.gov/pubmed/35852778 http://dx.doi.org/10.1007/s10266-022-00730-8 |
work_keys_str_mv | AT bhargavanishith comparisonofheatproductionandbonearchitecturechangesintheimplantsitepreparationwithcompressiveosteotomesosseodensificationtechniquepiezoelectricdevicesandstandarddrillsanexvivostudyonporcineribs AT perrottivittoria comparisonofheatproductionandbonearchitecturechangesintheimplantsitepreparationwithcompressiveosteotomesosseodensificationtechniquepiezoelectricdevicesandstandarddrillsanexvivostudyonporcineribs AT caponiovitocarloalberto comparisonofheatproductionandbonearchitecturechangesintheimplantsitepreparationwithcompressiveosteotomesosseodensificationtechniquepiezoelectricdevicesandstandarddrillsanexvivostudyonporcineribs AT matsubaravictorharuo comparisonofheatproductionandbonearchitecturechangesintheimplantsitepreparationwithcompressiveosteotomesosseodensificationtechniquepiezoelectricdevicesandstandarddrillsanexvivostudyonporcineribs AT patalwaladiana comparisonofheatproductionandbonearchitecturechangesintheimplantsitepreparationwithcompressiveosteotomesosseodensificationtechniquepiezoelectricdevicesandstandarddrillsanexvivostudyonporcineribs AT quarantaalessandro comparisonofheatproductionandbonearchitecturechangesintheimplantsitepreparationwithcompressiveosteotomesosseodensificationtechniquepiezoelectricdevicesandstandarddrillsanexvivostudyonporcineribs |