Cargando…
Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study
BACKGROUND: To evaluate the effectiveness and safety of robot-aided percutaneous triangular osteosynthesis combined with close reduction for vertically unstable sacrum fractures (VUSFs). METHODS: The data on 21 patients of the VUSF were retrospectively analyzed from November 2016 to January 2021. Ac...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9811800/ https://www.ncbi.nlm.nih.gov/pubmed/36597117 http://dx.doi.org/10.1186/s13018-022-03489-4 |
_version_ | 1784863601423548416 |
---|---|
author | Liu, Zhao-Jie Gu, Ya Jia, Jian |
author_facet | Liu, Zhao-Jie Gu, Ya Jia, Jian |
author_sort | Liu, Zhao-Jie |
collection | PubMed |
description | BACKGROUND: To evaluate the effectiveness and safety of robot-aided percutaneous triangular osteosynthesis combined with close reduction for vertically unstable sacrum fractures (VUSFs). METHODS: The data on 21 patients of the VUSF were retrospectively analyzed from November 2016 to January 2021. According to Denis classification, there were 3 cases in zone I, 11 cases in zone II, and 7 case in zone III. The main perioperative indicators were recorded. The maximal angulation and displacement deviations of the screws were analyzed by comparing the planned trajectory with the actual position. Postoperative X-ray radiographs and CT scans were obtained for evaluating the reduction quality. Functional outcome was scored with Majeed criterion. RESULTS: Fourteen patients of the unilateral VUSF and 7 patients of the bilateral VUSF underwent unilateral and bilateral triangular osteosynthesis with robotic assistance, respectively. No intraoperative neurovascular injuries and postoperative infection occurred. All patients were followed up for at least 12 months. The average operation time of posterior pelvic ring was 111.4 min, with the mean intraoperative bleeding of 110.5 ml. A total of 58 pedicle and iliosacral screws were implanted with robotic assistance. Of those, 52 screws were in the cancellous bone except 4 pedicle and 2 iliosacral screws cutting the cortical bone. The angulation and displacement deviations of the screws were 4.2° ± 2.5° and 1.7 ± 0.9 mm, respectively. The average displacement of the sacral fracture was reduced from 19.7 mm preoperatively to 3.1 mm postoperatively. According to Matta’s criterion, the reduction quality was graded as “excellent” in 13 patients and “good” in 8. All sacral fractures healed within 6 months except one fracture with nonunion. The mean Majeed score at the last follow-up was 89.6. CONCLUSIONS: Robot-aided triangular osteosynthesis combined with close reduction provide a safe and reliable option for percutaneous treatment of the fresh VUSF, with a high accuracy of iliosacral and pedicle screw implantation except insertion of iliac screws. Meanwhile, the technique may help to reduce incision-related complications. |
format | Online Article Text |
id | pubmed-9811800 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98118002023-01-05 Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study Liu, Zhao-Jie Gu, Ya Jia, Jian J Orthop Surg Res Research Article BACKGROUND: To evaluate the effectiveness and safety of robot-aided percutaneous triangular osteosynthesis combined with close reduction for vertically unstable sacrum fractures (VUSFs). METHODS: The data on 21 patients of the VUSF were retrospectively analyzed from November 2016 to January 2021. According to Denis classification, there were 3 cases in zone I, 11 cases in zone II, and 7 case in zone III. The main perioperative indicators were recorded. The maximal angulation and displacement deviations of the screws were analyzed by comparing the planned trajectory with the actual position. Postoperative X-ray radiographs and CT scans were obtained for evaluating the reduction quality. Functional outcome was scored with Majeed criterion. RESULTS: Fourteen patients of the unilateral VUSF and 7 patients of the bilateral VUSF underwent unilateral and bilateral triangular osteosynthesis with robotic assistance, respectively. No intraoperative neurovascular injuries and postoperative infection occurred. All patients were followed up for at least 12 months. The average operation time of posterior pelvic ring was 111.4 min, with the mean intraoperative bleeding of 110.5 ml. A total of 58 pedicle and iliosacral screws were implanted with robotic assistance. Of those, 52 screws were in the cancellous bone except 4 pedicle and 2 iliosacral screws cutting the cortical bone. The angulation and displacement deviations of the screws were 4.2° ± 2.5° and 1.7 ± 0.9 mm, respectively. The average displacement of the sacral fracture was reduced from 19.7 mm preoperatively to 3.1 mm postoperatively. According to Matta’s criterion, the reduction quality was graded as “excellent” in 13 patients and “good” in 8. All sacral fractures healed within 6 months except one fracture with nonunion. The mean Majeed score at the last follow-up was 89.6. CONCLUSIONS: Robot-aided triangular osteosynthesis combined with close reduction provide a safe and reliable option for percutaneous treatment of the fresh VUSF, with a high accuracy of iliosacral and pedicle screw implantation except insertion of iliac screws. Meanwhile, the technique may help to reduce incision-related complications. BioMed Central 2023-01-04 /pmc/articles/PMC9811800/ /pubmed/36597117 http://dx.doi.org/10.1186/s13018-022-03489-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Liu, Zhao-Jie Gu, Ya Jia, Jian Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
title | Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
title_full | Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
title_fullStr | Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
title_full_unstemmed | Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
title_short | Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
title_sort | robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9811800/ https://www.ncbi.nlm.nih.gov/pubmed/36597117 http://dx.doi.org/10.1186/s13018-022-03489-4 |
work_keys_str_mv | AT liuzhaojie roboticguidanceforpercutaneousplacementoftriangularosteosynthesisinverticallyunstablesacrumfracturesasinglecenterretrospectivestudy AT guya roboticguidanceforpercutaneousplacementoftriangularosteosynthesisinverticallyunstablesacrumfracturesasinglecenterretrospectivestudy AT jiajian roboticguidanceforpercutaneousplacementoftriangularosteosynthesisinverticallyunstablesacrumfracturesasinglecenterretrospectivestudy |