Cargando…
Acute iridocyclitis and cystoid macular edema related to kinked Hydrus(®) Microstent in advanced glaucoma
A 58-year-old male who underwent cataract extraction with combined intraocular lens and Hydrus(®) Microstent (Ivantis Inc, Irvine, CA, US) implantation 2 years ago in the right eye (OD) due to advanced glaucoma presented with blurry vision in right eye (OD) for 3 months. The visual acuity was 20/60...
Autores principales: | Karaca, Irmak, Korot, Edward, Ghoraba, Hashem, Regenold, Jonathan, Mobasserian, Azadeh, Khan, Youan, Zaidi, Moosa H., Or, Christopher, Nguyen, Quan D. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9811929/ https://www.ncbi.nlm.nih.gov/pubmed/36618568 http://dx.doi.org/10.4103/sjopt.sjopt_215_21 |
Ejemplares similares
-
Unilateral acute anterior uveitis with macular edema following the use of sildenafil citrate in a patient with HLA-B27 positivity
por: Regenold, Jonathan, et al.
Publicado: (2021) -
Hydrus Microstent malposition with uveitis-glaucoma-hyphema syndrome()
por: Capitena Young, Cara E., et al.
Publicado: (2022) -
Hydrus microstent implantation for surgical management of glaucoma: a review of design, efficacy and safety
por: Samet, Saba, et al.
Publicado: (2019) -
Structural changes of corneal epithelium in belantamab-associated superficial keratopathy using anterior segment optical coherence tomography
por: Matsumiya, Wataru, et al.
Publicado: (2021) -
Real-world efficacy of the Hydrus microstent in Black and Afro-Latinx patients with glaucoma: a retrospective study
por: Laroche, Daniel, et al.
Publicado: (2020)