Fully automated multi-grid cryoEM screening using Smart Leginon
Single-particle cryo-electron microscopy (cryoEM) is a swiftly growing method for understanding protein structure. With increasing demand for high-throughput, high-resolution cryoEM services comes greater demand for rapid and automated cryoEM grid and sample screening. During screening, optimal grid...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9812217/ https://www.ncbi.nlm.nih.gov/pubmed/36598504 http://dx.doi.org/10.1107/S2052252522010624 |
_version_ | 1784863681779073024 |
---|---|
author | Cheng, Anchi Kim, Paul T. Kuang, Huihui Mendez, Joshua H. Chua, Eugene Y. D. Maruthi, Kashyap Wei, Hui Sawh, Anjelique Aragon, Mahira F. Serbynovskyi, Viacheslav Neselu, Kasahun Eng, Edward T. Potter, Clinton S. Carragher, Bridget Bepler, Tristan Noble, Alex J. |
author_facet | Cheng, Anchi Kim, Paul T. Kuang, Huihui Mendez, Joshua H. Chua, Eugene Y. D. Maruthi, Kashyap Wei, Hui Sawh, Anjelique Aragon, Mahira F. Serbynovskyi, Viacheslav Neselu, Kasahun Eng, Edward T. Potter, Clinton S. Carragher, Bridget Bepler, Tristan Noble, Alex J. |
author_sort | Cheng, Anchi |
collection | PubMed |
description | Single-particle cryo-electron microscopy (cryoEM) is a swiftly growing method for understanding protein structure. With increasing demand for high-throughput, high-resolution cryoEM services comes greater demand for rapid and automated cryoEM grid and sample screening. During screening, optimal grids and sample conditions are identified for subsequent high-resolution data collection. Screening is a major bottleneck for new cryoEM projects because grids must be optimized for several factors, including grid type, grid hole size, sample concentration, buffer conditions, ice thickness and particle behavior. Even for mature projects, multiple grids are commonly screened to select a subset for high-resolution data collection. Here, machine learning and novel purpose-built image-processing and microscope-handling algorithms are incorporated into the automated data-collection software Leginon, to provide an open-source solution for fully automated high-throughput grid screening. This new version, broadly called Smart Leginon, emulates the actions of an operator in identifying areas on the grid to explore as potentially useful for data collection. Smart Leginon Autoscreen sequentially loads and examines grids from an automated specimen-exchange system to provide completely unattended grid screening across a set of grids. Comparisons between a multi-grid autoscreen session and conventional manual screening by 5 expert microscope operators are presented. On average, Autoscreen reduces operator time from ∼6 h to <10 min and provides a percentage of suitable images for evaluation comparable to the best operator. The ability of Smart Leginon to target holes that are particularly difficult to identify is analyzed. Finally, the utility of Smart Leginon is illustrated with three real-world multi-grid user screening/collection sessions, demonstrating the efficiency and flexibility of the software package. The fully automated functionality of Smart Leginon significantly reduces the burden on operator screening time, improves the throughput of screening and recovers idle microscope time, thereby improving availability of cryoEM services. |
format | Online Article Text |
id | pubmed-9812217 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-98122172023-01-09 Fully automated multi-grid cryoEM screening using Smart Leginon Cheng, Anchi Kim, Paul T. Kuang, Huihui Mendez, Joshua H. Chua, Eugene Y. D. Maruthi, Kashyap Wei, Hui Sawh, Anjelique Aragon, Mahira F. Serbynovskyi, Viacheslav Neselu, Kasahun Eng, Edward T. Potter, Clinton S. Carragher, Bridget Bepler, Tristan Noble, Alex J. IUCrJ Research Papers Single-particle cryo-electron microscopy (cryoEM) is a swiftly growing method for understanding protein structure. With increasing demand for high-throughput, high-resolution cryoEM services comes greater demand for rapid and automated cryoEM grid and sample screening. During screening, optimal grids and sample conditions are identified for subsequent high-resolution data collection. Screening is a major bottleneck for new cryoEM projects because grids must be optimized for several factors, including grid type, grid hole size, sample concentration, buffer conditions, ice thickness and particle behavior. Even for mature projects, multiple grids are commonly screened to select a subset for high-resolution data collection. Here, machine learning and novel purpose-built image-processing and microscope-handling algorithms are incorporated into the automated data-collection software Leginon, to provide an open-source solution for fully automated high-throughput grid screening. This new version, broadly called Smart Leginon, emulates the actions of an operator in identifying areas on the grid to explore as potentially useful for data collection. Smart Leginon Autoscreen sequentially loads and examines grids from an automated specimen-exchange system to provide completely unattended grid screening across a set of grids. Comparisons between a multi-grid autoscreen session and conventional manual screening by 5 expert microscope operators are presented. On average, Autoscreen reduces operator time from ∼6 h to <10 min and provides a percentage of suitable images for evaluation comparable to the best operator. The ability of Smart Leginon to target holes that are particularly difficult to identify is analyzed. Finally, the utility of Smart Leginon is illustrated with three real-world multi-grid user screening/collection sessions, demonstrating the efficiency and flexibility of the software package. The fully automated functionality of Smart Leginon significantly reduces the burden on operator screening time, improves the throughput of screening and recovers idle microscope time, thereby improving availability of cryoEM services. International Union of Crystallography 2023-01-01 /pmc/articles/PMC9812217/ /pubmed/36598504 http://dx.doi.org/10.1107/S2052252522010624 Text en © Anchi Cheng et al. 2023 https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Cheng, Anchi Kim, Paul T. Kuang, Huihui Mendez, Joshua H. Chua, Eugene Y. D. Maruthi, Kashyap Wei, Hui Sawh, Anjelique Aragon, Mahira F. Serbynovskyi, Viacheslav Neselu, Kasahun Eng, Edward T. Potter, Clinton S. Carragher, Bridget Bepler, Tristan Noble, Alex J. Fully automated multi-grid cryoEM screening using Smart Leginon |
title | Fully automated multi-grid cryoEM screening using Smart Leginon
|
title_full | Fully automated multi-grid cryoEM screening using Smart Leginon
|
title_fullStr | Fully automated multi-grid cryoEM screening using Smart Leginon
|
title_full_unstemmed | Fully automated multi-grid cryoEM screening using Smart Leginon
|
title_short | Fully automated multi-grid cryoEM screening using Smart Leginon
|
title_sort | fully automated multi-grid cryoem screening using smart leginon |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9812217/ https://www.ncbi.nlm.nih.gov/pubmed/36598504 http://dx.doi.org/10.1107/S2052252522010624 |
work_keys_str_mv | AT chenganchi fullyautomatedmultigridcryoemscreeningusingsmartleginon AT kimpault fullyautomatedmultigridcryoemscreeningusingsmartleginon AT kuanghuihui fullyautomatedmultigridcryoemscreeningusingsmartleginon AT mendezjoshuah fullyautomatedmultigridcryoemscreeningusingsmartleginon AT chuaeugeneyd fullyautomatedmultigridcryoemscreeningusingsmartleginon AT maruthikashyap fullyautomatedmultigridcryoemscreeningusingsmartleginon AT weihui fullyautomatedmultigridcryoemscreeningusingsmartleginon AT sawhanjelique fullyautomatedmultigridcryoemscreeningusingsmartleginon AT aragonmahiraf fullyautomatedmultigridcryoemscreeningusingsmartleginon AT serbynovskyiviacheslav fullyautomatedmultigridcryoemscreeningusingsmartleginon AT neselukasahun fullyautomatedmultigridcryoemscreeningusingsmartleginon AT engedwardt fullyautomatedmultigridcryoemscreeningusingsmartleginon AT potterclintons fullyautomatedmultigridcryoemscreeningusingsmartleginon AT carragherbridget fullyautomatedmultigridcryoemscreeningusingsmartleginon AT beplertristan fullyautomatedmultigridcryoemscreeningusingsmartleginon AT noblealexj fullyautomatedmultigridcryoemscreeningusingsmartleginon |