Cargando…
Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients
Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive neuromodulation technique. The purpose of our study is to explore the effects of low-frequency (0.5 Hz) and high-frequency (10 Hz) rTMS on neurological function, motor function, and excitability of cortex in Chinese ischemic stroke...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9812416/ https://www.ncbi.nlm.nih.gov/pubmed/35452441 http://dx.doi.org/10.1097/NRL.0000000000000435 |
_version_ | 1784863721155198976 |
---|---|
author | Wang, Chao Zeng, Qifan Yuan, Zhigang Wang, Wei Shen, Mei |
author_facet | Wang, Chao Zeng, Qifan Yuan, Zhigang Wang, Wei Shen, Mei |
author_sort | Wang, Chao |
collection | PubMed |
description | Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive neuromodulation technique. The purpose of our study is to explore the effects of low-frequency (0.5 Hz) and high-frequency (10 Hz) rTMS on neurological function, motor function, and excitability of cortex in Chinese ischemic stroke patients. MATERIALS AND METHODS: A total of 240 ischemic stroke patients were collected. The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS), motor-evoked potential (MEP) cortical latency, central motor conduction time (CMCT), Fugel-Meyer assessment (FMA), Berg balance scale (BBS), and modified Barthel index (MBI) scores were recorded. RESULTS: After treatment, the NIHSS, mRS, MEP cortical latency, CMCT, FMA, BBS, and MBI scores of the high-frequency group and low-frequency group were significantly improved than the sham stimulation group, and the changes in the low-frequency group were more significant (adjusted P<0.05). Compared with the sham stimulation group, high-frequency stimulation reduced the NIHSS score by 9.5%, mRS score by 12.6%, MEP latency by 2.5%, and CMCT by 5.8%, and increased the upper limb FMA scale by 16.4%, lower limb FMA scale by 8.8%, BBS by 26.3%, and MBI by 9.3%, while low-frequency stimulation reduced the NIHSS score by 23.8%, mRS score by 25.3%, MEP Latency by 11.7%, and CMCT by 9.1%, and increased the upper limb FMA scale by 24.1%, lower limb FMA scale by 18.4%, BBS by 27.4%, and MBI by 23.7% in our cohort. CONCLUSIONS: Low-frequency rTMS is better than high-frequency rTMS stimulation in improving neurological function, motor function, and excitability of cortex in ischemic stroke. |
format | Online Article Text |
id | pubmed-9812416 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-98124162023-01-12 Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients Wang, Chao Zeng, Qifan Yuan, Zhigang Wang, Wei Shen, Mei Neurologist Original Articles Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive neuromodulation technique. The purpose of our study is to explore the effects of low-frequency (0.5 Hz) and high-frequency (10 Hz) rTMS on neurological function, motor function, and excitability of cortex in Chinese ischemic stroke patients. MATERIALS AND METHODS: A total of 240 ischemic stroke patients were collected. The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS), motor-evoked potential (MEP) cortical latency, central motor conduction time (CMCT), Fugel-Meyer assessment (FMA), Berg balance scale (BBS), and modified Barthel index (MBI) scores were recorded. RESULTS: After treatment, the NIHSS, mRS, MEP cortical latency, CMCT, FMA, BBS, and MBI scores of the high-frequency group and low-frequency group were significantly improved than the sham stimulation group, and the changes in the low-frequency group were more significant (adjusted P<0.05). Compared with the sham stimulation group, high-frequency stimulation reduced the NIHSS score by 9.5%, mRS score by 12.6%, MEP latency by 2.5%, and CMCT by 5.8%, and increased the upper limb FMA scale by 16.4%, lower limb FMA scale by 8.8%, BBS by 26.3%, and MBI by 9.3%, while low-frequency stimulation reduced the NIHSS score by 23.8%, mRS score by 25.3%, MEP Latency by 11.7%, and CMCT by 9.1%, and increased the upper limb FMA scale by 24.1%, lower limb FMA scale by 18.4%, BBS by 27.4%, and MBI by 23.7% in our cohort. CONCLUSIONS: Low-frequency rTMS is better than high-frequency rTMS stimulation in improving neurological function, motor function, and excitability of cortex in ischemic stroke. Lippincott Williams & Wilkins 2022-04-22 /pmc/articles/PMC9812416/ /pubmed/35452441 http://dx.doi.org/10.1097/NRL.0000000000000435 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Articles Wang, Chao Zeng, Qifan Yuan, Zhigang Wang, Wei Shen, Mei Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients |
title | Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients |
title_full | Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients |
title_fullStr | Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients |
title_full_unstemmed | Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients |
title_short | Effects of Low-Frequency (0.5 Hz) and High-Frequency (10 Hz) Repetitive Transcranial Magnetic Stimulation on Neurological Function, Motor Function, and Excitability of Cortex in Ischemic Stroke Patients |
title_sort | effects of low-frequency (0.5 hz) and high-frequency (10 hz) repetitive transcranial magnetic stimulation on neurological function, motor function, and excitability of cortex in ischemic stroke patients |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9812416/ https://www.ncbi.nlm.nih.gov/pubmed/35452441 http://dx.doi.org/10.1097/NRL.0000000000000435 |
work_keys_str_mv | AT wangchao effectsoflowfrequency05hzandhighfrequency10hzrepetitivetranscranialmagneticstimulationonneurologicalfunctionmotorfunctionandexcitabilityofcortexinischemicstrokepatients AT zengqifan effectsoflowfrequency05hzandhighfrequency10hzrepetitivetranscranialmagneticstimulationonneurologicalfunctionmotorfunctionandexcitabilityofcortexinischemicstrokepatients AT yuanzhigang effectsoflowfrequency05hzandhighfrequency10hzrepetitivetranscranialmagneticstimulationonneurologicalfunctionmotorfunctionandexcitabilityofcortexinischemicstrokepatients AT wangwei effectsoflowfrequency05hzandhighfrequency10hzrepetitivetranscranialmagneticstimulationonneurologicalfunctionmotorfunctionandexcitabilityofcortexinischemicstrokepatients AT shenmei effectsoflowfrequency05hzandhighfrequency10hzrepetitivetranscranialmagneticstimulationonneurologicalfunctionmotorfunctionandexcitabilityofcortexinischemicstrokepatients |