Cargando…
Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement
To define the influence of air, SF6 gas and silicon oil 1000cs tamponade injection and oil tamponade removal on corneal biomechanics, central corneal thickness and intraocular pressure. 77 eyes referred to vitrectomy were divided into 4 groups: 19 to air tamponade, 21 to SF6 tamponade, 19 to oil tam...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9813351/ https://www.ncbi.nlm.nih.gov/pubmed/36599896 http://dx.doi.org/10.1038/s41598-023-27407-8 |
_version_ | 1784863900744810496 |
---|---|
author | Pniakowska, Zofia Jurowski, Piotr |
author_facet | Pniakowska, Zofia Jurowski, Piotr |
author_sort | Pniakowska, Zofia |
collection | PubMed |
description | To define the influence of air, SF6 gas and silicon oil 1000cs tamponade injection and oil tamponade removal on corneal biomechanics, central corneal thickness and intraocular pressure. 77 eyes referred to vitrectomy were divided into 4 groups: 19 to air tamponade, 21 to SF6 tamponade, 19 to oil tamponade, 18 to oil tamponade removal. Pre- and postoperative corneal hysteresis, corneal resistance factor, corneal thickness, Goldman intraocular pressure (GAT) and corneal compensated intraocular pressure (IOPcc) were analysed. GAT and IOPcc did not change after the air or SF6 tamponade. The oil tamponade injection caused increase in GAT and IOPcc, while the oil removal caused reduction in those parameters. In all groups, preoperative and postoperative values of GAT and IOPcc did not differ. There was no change in corneal thickness and biomechanics after air, SF6 or oil tamponade while after removal of oil those parameters are decreased. The air, SF6 and oil tamponade does not change the corneal thickness and corneal biomechanics. The removal of oil causes decrease in corneal thickness and biomechanics which can lead to bias in intraocular pressure measurement. GAT and IOPcc did not differ in eyes pre- and post-vitrectomy, being similarly reliable measure. |
format | Online Article Text |
id | pubmed-9813351 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-98133512023-01-06 Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement Pniakowska, Zofia Jurowski, Piotr Sci Rep Article To define the influence of air, SF6 gas and silicon oil 1000cs tamponade injection and oil tamponade removal on corneal biomechanics, central corneal thickness and intraocular pressure. 77 eyes referred to vitrectomy were divided into 4 groups: 19 to air tamponade, 21 to SF6 tamponade, 19 to oil tamponade, 18 to oil tamponade removal. Pre- and postoperative corneal hysteresis, corneal resistance factor, corneal thickness, Goldman intraocular pressure (GAT) and corneal compensated intraocular pressure (IOPcc) were analysed. GAT and IOPcc did not change after the air or SF6 tamponade. The oil tamponade injection caused increase in GAT and IOPcc, while the oil removal caused reduction in those parameters. In all groups, preoperative and postoperative values of GAT and IOPcc did not differ. There was no change in corneal thickness and biomechanics after air, SF6 or oil tamponade while after removal of oil those parameters are decreased. The air, SF6 and oil tamponade does not change the corneal thickness and corneal biomechanics. The removal of oil causes decrease in corneal thickness and biomechanics which can lead to bias in intraocular pressure measurement. GAT and IOPcc did not differ in eyes pre- and post-vitrectomy, being similarly reliable measure. Nature Publishing Group UK 2023-01-04 /pmc/articles/PMC9813351/ /pubmed/36599896 http://dx.doi.org/10.1038/s41598-023-27407-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Pniakowska, Zofia Jurowski, Piotr Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
title | Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
title_full | Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
title_fullStr | Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
title_full_unstemmed | Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
title_short | Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
title_sort | early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9813351/ https://www.ncbi.nlm.nih.gov/pubmed/36599896 http://dx.doi.org/10.1038/s41598-023-27407-8 |
work_keys_str_mv | AT pniakowskazofia earlyinfluenceofendotamponadeoncornealbiomechanicalparameterscentralcornealthicknessandaccuracyofintraocularpressuremeasurement AT jurowskipiotr earlyinfluenceofendotamponadeoncornealbiomechanicalparameterscentralcornealthicknessandaccuracyofintraocularpressuremeasurement |