Semi-automated serum steroid profiling with tandem mass spectrometry

OBJECTIVES: Highly selective and sensitive multi-analyte methods for the analysis of steroids are attractive for the diagnosis of endocrine diseases. Commercially available kits are increasingly used for this purpose. These methods involve laborious solid phase extraction, and the respective panels...

Descripción completa

Detalles Bibliográficos
Autores principales: Rakete, Sophie, Schubert, Tom, Vogeser, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9813517/
https://www.ncbi.nlm.nih.gov/pubmed/36619216
http://dx.doi.org/10.1016/j.jmsacl.2022.12.006
Descripción
Sumario:OBJECTIVES: Highly selective and sensitive multi-analyte methods for the analysis of steroids are attractive for the diagnosis of endocrine diseases. Commercially available kits are increasingly used for this purpose. These methods involve laborious solid phase extraction, and the respective panels of target analytes are incomplete. We wanted to investigate whether an improvement of kit solutions is possible by introducing automated on-line solid phase extraction (SPE) and combining originally separate analyte panels. METHODS: Sample preparation was performed using automated on-line SPE on a high-pressure stable extraction column. Chromatographic separation, including isobaric compounds, was achieved using a 0.25 mM ammonium fluoride-methanol gradient on a small particle size biphenyl column. Standard compounds and internal standard mixtures of two panels of a commercially available kit were combined to achieve an optimized and straightforward detection of 15 endogenous steroids. Validation was performed according to the European Medicines Agency (EMA) guidelines with slight modifications. RESULTS: Validation was successfully performed for all steroids over a clinically relevant calibration range. Deviations of intra- and inter-assay accuracy and precision results passed the criteria and no relevant matrix effects were detected due to highly effective sample preparation. External quality assessment samples showed the applicability as a routine diagnostic method, which was affirmed by the analyses of anonymized clinical samples. CONCLUSIONS: It was found possible to complement a commercially available kit for quantitative serum steroid profiling based on isotope dilution LC-MS/MS by implementing automated on-line SPE, thereby improving the practicality and robustness of the measurement procedure.