Fly-scan-oriented motion analyses and upgraded beamline integration architecture for the High-Dynamic Double-Crystal Monochromator at Sirius/LNLS

The High-Dynamic Double-Crystal Monochromator (HD-DCM) is a mechatronic system with unique control-based architecture and deep paradigm changes as compared with traditional beamline monochromators. Aiming at unprecedented inter-crystal positioning stability in vertical-bounce double-crystal monochro...

Descripción completa

Detalles Bibliográficos
Autores principales: Geraldes, Renan Ramalho, Luiz, Sergio Augusto Lordano, de Brito Neto, João Leandro, Soares, Telles René Silva, dos Reis, Ricardo Donizeth, Calligaris, Guilherme A., Witvoet, Gert, Vermeulen, J. P. M. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9814047/
https://www.ncbi.nlm.nih.gov/pubmed/36601930
http://dx.doi.org/10.1107/S1600577522010724
Descripción
Sumario:The High-Dynamic Double-Crystal Monochromator (HD-DCM) is a mechatronic system with unique control-based architecture and deep paradigm changes as compared with traditional beamline monochromators. Aiming at unprecedented inter-crystal positioning stability in vertical-bounce double-crystal monochromators (DCMs) of the order of 10 nrad RMS (1 Hz to 2.5 kHz), and not only in fixed-energy but also in fly-scan operation, it has been developed according to a ‘first-time right’ predictive design approach for hard X-ray beamlines at Sirius, the fourth-generation light source at the Brazilian Synchrotron Light Laboratory (LNLS/CNPEM). This work explores some of the challenges that emerge with this new technology and presents the latest commissioning results that demonstrate the unparallel performances of the HD-DCM at the undulator-based EMA (Extreme Methods of Analysis) beamline at Sirius. With the enabled fast spectroscopy fly-scan possibilities, a new energy-tuning evaluation method, based on wave-propagation simulations, becomes part of a motion-oriented analysis that is carried out to derive the multi-axis non-linear positioning problem, covering not only energy selection and fixed exit in the HD-DCM but also the emission spectrum of an adjustable-phase undulator (APU). The HD-DCM control scheme and its flexible operation modes are described in detail as well. Furthermore, a new integration topology between the HD-DCM and EMA’s APU, coming already close to ultimate motion levels, is described and validated.