Cargando…

GCL loss in BRAO

PURPOSE: Our recent publication used optical coherence tomography (OCT) to follow thinning of the retinal ganglion cell layer (GCL) in central retinal artery occlusion (CRAO). Thinning of the inner layers also occurs in patients with branch retinal artery occlusion (BRAO). The mechanism for such thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Shearer, Thomas R., Steinkamp, Peter N., Parker, Maria, Azuma, Mitsuyoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9815566/
https://www.ncbi.nlm.nih.gov/pubmed/36603006
http://dx.doi.org/10.1371/journal.pone.0279920
_version_ 1784864348092497920
author Shearer, Thomas R.
Steinkamp, Peter N.
Parker, Maria
Azuma, Mitsuyoshi
author_facet Shearer, Thomas R.
Steinkamp, Peter N.
Parker, Maria
Azuma, Mitsuyoshi
author_sort Shearer, Thomas R.
collection PubMed
description PURPOSE: Our recent publication used optical coherence tomography (OCT) to follow thinning of the retinal ganglion cell layer (GCL) in central retinal artery occlusion (CRAO). Thinning of the inner layers also occurs in patients with branch retinal artery occlusion (BRAO). The mechanism for such thinning may be partially due to proteolysis by a calcium-activated protease called calpain. Calpain inhibitor SNJ-1945 ameliorated the proteolysis in a past series of model experiments. The purposes of the present retrospective study were to: 1) use segmentation analysis of OCT images to follow the loss of retinal layers in BRAO compared to CRAO patients, and 2) predict the number of patients and days of observation needed for a clinical trial of a calpain inhibitor against BRAO. METHODS: A retrospective, case control study was conducted by computer-aided search in a medical records database for BRAO (ICD10 Code H34.239) with at least one OCT procedure (CPT: 92134). Non-proliferative, co-morbid eye diseases were allowed in the patient data base, and manual correction of auto-segmentation errors was performed. GCL thickness changes were followed over time and Cohen-d/sample size statistics were used to predict minimal patients needed for drug trials. RESULTS: The thickness of the GCL layer in BRAO decreased rapidly with time as in CRAO, but in more limited quadrants. The data, as fit to a single-phase decay curve, showed that GCL thickness could be used to provide sample size statistics in a clinical trial to test a calpain inhibitor. For example, a 60-day trial with a 60% effective inhibitor would need a minimum of 29 patients. CONCLUSIONS: Using thickness changes in the GCL layer to monitor the efficacy of potential inhibitors against BRAO and CRAO is practical in human trials requiring a reasonable number of patients and relatively short trial period. TRANSLATIONAL RELEVANCE: Measurement of GCL thickness would be a useful indicator of amelioration of BRAO and CRAO progression in a clinical trial of a putative inhibitor.
format Online
Article
Text
id pubmed-9815566
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-98155662023-01-06 GCL loss in BRAO Shearer, Thomas R. Steinkamp, Peter N. Parker, Maria Azuma, Mitsuyoshi PLoS One Research Article PURPOSE: Our recent publication used optical coherence tomography (OCT) to follow thinning of the retinal ganglion cell layer (GCL) in central retinal artery occlusion (CRAO). Thinning of the inner layers also occurs in patients with branch retinal artery occlusion (BRAO). The mechanism for such thinning may be partially due to proteolysis by a calcium-activated protease called calpain. Calpain inhibitor SNJ-1945 ameliorated the proteolysis in a past series of model experiments. The purposes of the present retrospective study were to: 1) use segmentation analysis of OCT images to follow the loss of retinal layers in BRAO compared to CRAO patients, and 2) predict the number of patients and days of observation needed for a clinical trial of a calpain inhibitor against BRAO. METHODS: A retrospective, case control study was conducted by computer-aided search in a medical records database for BRAO (ICD10 Code H34.239) with at least one OCT procedure (CPT: 92134). Non-proliferative, co-morbid eye diseases were allowed in the patient data base, and manual correction of auto-segmentation errors was performed. GCL thickness changes were followed over time and Cohen-d/sample size statistics were used to predict minimal patients needed for drug trials. RESULTS: The thickness of the GCL layer in BRAO decreased rapidly with time as in CRAO, but in more limited quadrants. The data, as fit to a single-phase decay curve, showed that GCL thickness could be used to provide sample size statistics in a clinical trial to test a calpain inhibitor. For example, a 60-day trial with a 60% effective inhibitor would need a minimum of 29 patients. CONCLUSIONS: Using thickness changes in the GCL layer to monitor the efficacy of potential inhibitors against BRAO and CRAO is practical in human trials requiring a reasonable number of patients and relatively short trial period. TRANSLATIONAL RELEVANCE: Measurement of GCL thickness would be a useful indicator of amelioration of BRAO and CRAO progression in a clinical trial of a putative inhibitor. Public Library of Science 2023-01-05 /pmc/articles/PMC9815566/ /pubmed/36603006 http://dx.doi.org/10.1371/journal.pone.0279920 Text en © 2023 Shearer et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Shearer, Thomas R.
Steinkamp, Peter N.
Parker, Maria
Azuma, Mitsuyoshi
GCL loss in BRAO
title GCL loss in BRAO
title_full GCL loss in BRAO
title_fullStr GCL loss in BRAO
title_full_unstemmed GCL loss in BRAO
title_short GCL loss in BRAO
title_sort gcl loss in brao
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9815566/
https://www.ncbi.nlm.nih.gov/pubmed/36603006
http://dx.doi.org/10.1371/journal.pone.0279920
work_keys_str_mv AT shearerthomasr gcllossinbrao
AT steinkamppetern gcllossinbrao
AT parkermaria gcllossinbrao
AT azumamitsuyoshi gcllossinbrao