Cargando…

Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials

OBJECTIVE: This meta-analysis with statistical power analysis aimed to evaluate the difference between full-endoscopic and microscopic spinal decompression in treating spinal stenosis. METHODS: We searched PubMed, Embase, CENTRAL (Cochrane Central Register of Controlled Trials), and CNKI (China Nati...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Zechuan, Wang, Huan, Li, Wenkai, Hu, Weihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Spinal Neurosurgery Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816578/
https://www.ncbi.nlm.nih.gov/pubmed/36597637
http://dx.doi.org/10.14245/ns.2244600.300
_version_ 1784864567087595520
author Yang, Zechuan
Wang, Huan
Li, Wenkai
Hu, Weihua
author_facet Yang, Zechuan
Wang, Huan
Li, Wenkai
Hu, Weihua
author_sort Yang, Zechuan
collection PubMed
description OBJECTIVE: This meta-analysis with statistical power analysis aimed to evaluate the difference between full-endoscopic and microscopic spinal decompression in treating spinal stenosis. METHODS: We searched PubMed, Embase, CENTRAL (Cochrane Central Register of Controlled Trials), and CNKI (China National Knowledge Infrastructure) for relevant randomized controlled trials (RCTs) regarding the comparison of full-endoscopic versus microscopic spinal decompression in treating lumbar spinal stenosis through February 28, 2022. Two independent investigators selected studies, extracted information, and appraised methodological quality. Meta-analysis was conducted using RevMan 5.4 and STATA 14.0, and statistical power analysis was performed using G*Power 3.1. RESULTS: Six RCTs involving 646 patients met selection criteria. Meta-analysis suggested that, compared with microscopic decompression, full-endoscopic spinal decompression achieved more leg pain improvement (mean difference [MD], -0.20; 95% confidence interval [CI], -0.30 to -0.10; p = 0.001), shortened operative time (MD, -12.71; 95% CI, -18.27 to -7.15; p < 0.001), and decreased the incidence of complications (risk ratio, 0.43; 95% CI, 0.22–0.82; p = 0.01), which was supported by a statistical power of 98.57%, 99.97%, and 81.88%, respectively. CONCLUSION: Full-endoscopic spinal decompression is a better treatment for lumbar spinal stenosis, showing more effective leg pain improvement, shorter operative time, and fewer complications than microscopic decompression.
format Online
Article
Text
id pubmed-9816578
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Spinal Neurosurgery Society
record_format MEDLINE/PubMed
spelling pubmed-98165782023-01-11 Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials Yang, Zechuan Wang, Huan Li, Wenkai Hu, Weihua Neurospine Original Article OBJECTIVE: This meta-analysis with statistical power analysis aimed to evaluate the difference between full-endoscopic and microscopic spinal decompression in treating spinal stenosis. METHODS: We searched PubMed, Embase, CENTRAL (Cochrane Central Register of Controlled Trials), and CNKI (China National Knowledge Infrastructure) for relevant randomized controlled trials (RCTs) regarding the comparison of full-endoscopic versus microscopic spinal decompression in treating lumbar spinal stenosis through February 28, 2022. Two independent investigators selected studies, extracted information, and appraised methodological quality. Meta-analysis was conducted using RevMan 5.4 and STATA 14.0, and statistical power analysis was performed using G*Power 3.1. RESULTS: Six RCTs involving 646 patients met selection criteria. Meta-analysis suggested that, compared with microscopic decompression, full-endoscopic spinal decompression achieved more leg pain improvement (mean difference [MD], -0.20; 95% confidence interval [CI], -0.30 to -0.10; p = 0.001), shortened operative time (MD, -12.71; 95% CI, -18.27 to -7.15; p < 0.001), and decreased the incidence of complications (risk ratio, 0.43; 95% CI, 0.22–0.82; p = 0.01), which was supported by a statistical power of 98.57%, 99.97%, and 81.88%, respectively. CONCLUSION: Full-endoscopic spinal decompression is a better treatment for lumbar spinal stenosis, showing more effective leg pain improvement, shorter operative time, and fewer complications than microscopic decompression. Korean Spinal Neurosurgery Society 2022-12 2022-12-31 /pmc/articles/PMC9816578/ /pubmed/36597637 http://dx.doi.org/10.14245/ns.2244600.300 Text en Copyright © 2022 by the Korean Spinal Neurosurgery Society https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yang, Zechuan
Wang, Huan
Li, Wenkai
Hu, Weihua
Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials
title Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials
title_full Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials
title_fullStr Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials
title_full_unstemmed Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials
title_short Comparative Effects and Safety of Full-Endoscopic Versus Microscopic Spinal Decompression for Lumbar Spinal Stenosis: A Meta-Analysis and Statistical Power Analysis of 6 Randomized Controlled Trials
title_sort comparative effects and safety of full-endoscopic versus microscopic spinal decompression for lumbar spinal stenosis: a meta-analysis and statistical power analysis of 6 randomized controlled trials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816578/
https://www.ncbi.nlm.nih.gov/pubmed/36597637
http://dx.doi.org/10.14245/ns.2244600.300
work_keys_str_mv AT yangzechuan comparativeeffectsandsafetyoffullendoscopicversusmicroscopicspinaldecompressionforlumbarspinalstenosisametaanalysisandstatisticalpoweranalysisof6randomizedcontrolledtrials
AT wanghuan comparativeeffectsandsafetyoffullendoscopicversusmicroscopicspinaldecompressionforlumbarspinalstenosisametaanalysisandstatisticalpoweranalysisof6randomizedcontrolledtrials
AT liwenkai comparativeeffectsandsafetyoffullendoscopicversusmicroscopicspinaldecompressionforlumbarspinalstenosisametaanalysisandstatisticalpoweranalysisof6randomizedcontrolledtrials
AT huweihua comparativeeffectsandsafetyoffullendoscopicversusmicroscopicspinaldecompressionforlumbarspinalstenosisametaanalysisandstatisticalpoweranalysisof6randomizedcontrolledtrials