Cargando…
Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images
PURPOSE: The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI). METHODS: This retro...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816709/ https://www.ncbi.nlm.nih.gov/pubmed/36475357 http://dx.doi.org/10.14366/usg.22104 |
_version_ | 1784864597982838784 |
---|---|
author | Youn, Seo Yeon Choi, Moon Hyung Lee, Young Joon Grimm, Robert von Busch, Heinrich Han, Dongyeob Son, Yohan Lou, Bin Kamen, Ali |
author_facet | Youn, Seo Yeon Choi, Moon Hyung Lee, Young Joon Grimm, Robert von Busch, Heinrich Han, Dongyeob Son, Yohan Lou, Bin Kamen, Ali |
author_sort | Youn, Seo Yeon |
collection | PubMed |
description | PURPOSE: The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI). METHODS: This retrospective study included 456 patients with transrectal US and MRI from two university hospitals. Two radiologists independently measured the prostate gland diameters on US and MRI: AP diameters on axial and sagittal images, transverse, and longitudinal diameters on midsagittal images. The volume estimates, volume(ax) and volume(sag), were calculated from the ellipsoid formula by using the AP diameter on axial and sagittal images, respectively. The prostate volume extracted from MRI-based whole-gland segmentation was considered the gold standard. The intraclass correlation coefficient (ICC) was used to evaluate the inter-method agreement between volume(ax) and volume(sag), and agreement with the gold standard. The Wilcoxon signedrank test was used to analyze the differences between the volume estimates and the gold standard. RESULTS: The prostate gland volume estimates showed excellent inter-method agreement, and excellent agreement with the gold standard (ICCs >0.9). Compared with the gold standard, the volume estimates were significantly larger on MRI and significantly smaller on US (P<0.001). The volume difference (segmented volume–volume estimate) was greater in patients with larger prostate glands, especially on US. CONCLUSION: Volume(ax) and volume(sag) showed excellent inter-method agreement and excellent agreement with the gold standard on both US and MRI. However, prostate volume was overestimated on MRI and underestimated on US. |
format | Online Article Text |
id | pubmed-9816709 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-98167092023-01-11 Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images Youn, Seo Yeon Choi, Moon Hyung Lee, Young Joon Grimm, Robert von Busch, Heinrich Han, Dongyeob Son, Yohan Lou, Bin Kamen, Ali Ultrasonography Original Article PURPOSE: The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI). METHODS: This retrospective study included 456 patients with transrectal US and MRI from two university hospitals. Two radiologists independently measured the prostate gland diameters on US and MRI: AP diameters on axial and sagittal images, transverse, and longitudinal diameters on midsagittal images. The volume estimates, volume(ax) and volume(sag), were calculated from the ellipsoid formula by using the AP diameter on axial and sagittal images, respectively. The prostate volume extracted from MRI-based whole-gland segmentation was considered the gold standard. The intraclass correlation coefficient (ICC) was used to evaluate the inter-method agreement between volume(ax) and volume(sag), and agreement with the gold standard. The Wilcoxon signedrank test was used to analyze the differences between the volume estimates and the gold standard. RESULTS: The prostate gland volume estimates showed excellent inter-method agreement, and excellent agreement with the gold standard (ICCs >0.9). Compared with the gold standard, the volume estimates were significantly larger on MRI and significantly smaller on US (P<0.001). The volume difference (segmented volume–volume estimate) was greater in patients with larger prostate glands, especially on US. CONCLUSION: Volume(ax) and volume(sag) showed excellent inter-method agreement and excellent agreement with the gold standard on both US and MRI. However, prostate volume was overestimated on MRI and underestimated on US. Korean Society of Ultrasound in Medicine 2023-01 2022-10-24 /pmc/articles/PMC9816709/ /pubmed/36475357 http://dx.doi.org/10.14366/usg.22104 Text en Copyright © 2023 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Youn, Seo Yeon Choi, Moon Hyung Lee, Young Joon Grimm, Robert von Busch, Heinrich Han, Dongyeob Son, Yohan Lou, Bin Kamen, Ali Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
title | Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
title_full | Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
title_fullStr | Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
title_full_unstemmed | Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
title_short | Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
title_sort | prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816709/ https://www.ncbi.nlm.nih.gov/pubmed/36475357 http://dx.doi.org/10.14366/usg.22104 |
work_keys_str_mv | AT younseoyeon prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT choimoonhyung prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT leeyoungjoon prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT grimmrobert prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT vonbuschheinrich prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT handongyeob prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT sonyohan prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT loubin prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages AT kamenali prostateglandvolumeestimationanteroposteriordiametersmeasuredonaxialversussagittalultrasonographyandmagneticresonanceimages |