Cargando…
Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences
BACKGROUND: Cone-beam computed tomography (CBCT) is the gold standard for evaluating condylar osseous changes. However, the radiation risk and low soft-tissue resolution of CBCT make it unsuitable for evaluating soft tissue such as the articular disc and lateral pterygoid muscle. This study aimed to...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816719/ https://www.ncbi.nlm.nih.gov/pubmed/36620157 http://dx.doi.org/10.21037/qims-22-424 |
_version_ | 1784864600407146496 |
---|---|
author | Ming, Xing Cheng, Xinge Tian, Chong Li, Wuchao Wang, Rongpin Qian, Chunqi Zeng, Xianchun |
author_facet | Ming, Xing Cheng, Xinge Tian, Chong Li, Wuchao Wang, Rongpin Qian, Chunqi Zeng, Xianchun |
author_sort | Ming, Xing |
collection | PubMed |
description | BACKGROUND: Cone-beam computed tomography (CBCT) is the gold standard for evaluating condylar osseous changes. However, the radiation risk and low soft-tissue resolution of CBCT make it unsuitable for evaluating soft tissue such as the articular disc and lateral pterygoid muscle. This study aimed to qualitatively and quantitatively evaluate the feasibility and advantages of using wireless detectors (WD) with proton density–weighted imaging (PDWI) sequences to image condyle changes in patients with temporomandibular disorders (TMD). METHODS: This study involved 20 patients (male =8, female =12; mean age 31.65 years, SD 12.68 years) with TMD. All participants underwent a closed oblique sagittal PDWI scan with head/neck coupling coiling (HNCC) and wireless detector–HNCC (WD-HNCC) on a 3.0 T magnetic resonance imaging (MRI) scanner. Subsequently, the changes in the condyle bones in the scanned images for the 2 image types were scored subjectively and compared qualitatively. The contrast-to-noise ratio (CNR) of the 2 types of scanned images was compared quantitatively. The comparison of CNR differences between the 2 types of images was performed using the paired t-test. The kappa statistic was used to test the consistency of quantitative analyses of MRI images between observers. The subjective scores of condylar osseous changes in the 2 types of images were compared by paired rank-sum test. A P value <0.05 was considered statistically significant. RESULTS: A total of 40 condyles from 20 patients were scanned. Among them, 8 condyles showed no bone changes, and the other 32 condyles demonstrated condylar osseous changes of varying degrees and nature. These 32 condyles were used in the subsequent analysis. As compared to images acquired by HNCC in the PDWI sequence, the WD-HNCC images more clearly showed mandibular osteophyte, bone cortical erosion, subcortical cystic focus, and bone cortical hyperplasia and thickening. In addition, the WD-HNCC was demonstrated to improve image CNR by 158.9% compared to HNCC (28.17±16.01 vs. 10.88±6.53; t=8.63; P=0.001). CONCLUSIONS: WD-HNCC in PDWI sequences is suitable for imaging the condylar bone changes of patients with TMD and significantly improves the image quality. |
format | Online Article Text |
id | pubmed-9816719 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-98167192023-01-07 Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences Ming, Xing Cheng, Xinge Tian, Chong Li, Wuchao Wang, Rongpin Qian, Chunqi Zeng, Xianchun Quant Imaging Med Surg Original Article BACKGROUND: Cone-beam computed tomography (CBCT) is the gold standard for evaluating condylar osseous changes. However, the radiation risk and low soft-tissue resolution of CBCT make it unsuitable for evaluating soft tissue such as the articular disc and lateral pterygoid muscle. This study aimed to qualitatively and quantitatively evaluate the feasibility and advantages of using wireless detectors (WD) with proton density–weighted imaging (PDWI) sequences to image condyle changes in patients with temporomandibular disorders (TMD). METHODS: This study involved 20 patients (male =8, female =12; mean age 31.65 years, SD 12.68 years) with TMD. All participants underwent a closed oblique sagittal PDWI scan with head/neck coupling coiling (HNCC) and wireless detector–HNCC (WD-HNCC) on a 3.0 T magnetic resonance imaging (MRI) scanner. Subsequently, the changes in the condyle bones in the scanned images for the 2 image types were scored subjectively and compared qualitatively. The contrast-to-noise ratio (CNR) of the 2 types of scanned images was compared quantitatively. The comparison of CNR differences between the 2 types of images was performed using the paired t-test. The kappa statistic was used to test the consistency of quantitative analyses of MRI images between observers. The subjective scores of condylar osseous changes in the 2 types of images were compared by paired rank-sum test. A P value <0.05 was considered statistically significant. RESULTS: A total of 40 condyles from 20 patients were scanned. Among them, 8 condyles showed no bone changes, and the other 32 condyles demonstrated condylar osseous changes of varying degrees and nature. These 32 condyles were used in the subsequent analysis. As compared to images acquired by HNCC in the PDWI sequence, the WD-HNCC images more clearly showed mandibular osteophyte, bone cortical erosion, subcortical cystic focus, and bone cortical hyperplasia and thickening. In addition, the WD-HNCC was demonstrated to improve image CNR by 158.9% compared to HNCC (28.17±16.01 vs. 10.88±6.53; t=8.63; P=0.001). CONCLUSIONS: WD-HNCC in PDWI sequences is suitable for imaging the condylar bone changes of patients with TMD and significantly improves the image quality. AME Publishing Company 2022-10-27 2023-01-01 /pmc/articles/PMC9816719/ /pubmed/36620157 http://dx.doi.org/10.21037/qims-22-424 Text en 2023 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Ming, Xing Cheng, Xinge Tian, Chong Li, Wuchao Wang, Rongpin Qian, Chunqi Zeng, Xianchun Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
title | Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
title_full | Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
title_fullStr | Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
title_full_unstemmed | Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
title_short | Evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
title_sort | evaluation of condylar osseous changes using a wireless detector with proton density–weighted imaging sequences |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816719/ https://www.ncbi.nlm.nih.gov/pubmed/36620157 http://dx.doi.org/10.21037/qims-22-424 |
work_keys_str_mv | AT mingxing evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences AT chengxinge evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences AT tianchong evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences AT liwuchao evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences AT wangrongpin evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences AT qianchunqi evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences AT zengxianchun evaluationofcondylarosseouschangesusingawirelessdetectorwithprotondensityweightedimagingsequences |