Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad
Evaporative cooler is one of the methods that have been used to keep buildings at a comfortable temperature since ancient times. This type of cooler is particularly suitable for hot and arid areas. This research examines the design and testing of an indirect evaporative cooler system utilizing heat...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816784/ https://www.ncbi.nlm.nih.gov/pubmed/36619457 http://dx.doi.org/10.1016/j.heliyon.2022.e12508 |
_version_ | 1784864616967307264 |
---|---|
author | Sofia, Evi Putra, Nandy Kosasih, Engkos A. |
author_facet | Sofia, Evi Putra, Nandy Kosasih, Engkos A. |
author_sort | Sofia, Evi |
collection | PubMed |
description | Evaporative cooler is one of the methods that have been used to keep buildings at a comfortable temperature since ancient times. This type of cooler is particularly suitable for hot and arid areas. This research examines the design and testing of an indirect evaporative cooler system utilizing heat pipes as heat exchangers and natural fibers as cooling pads. An experiment was performed on a laboratory scale with three different types of natural fiber cooling pad materials: pineapple leaf, ramie, and luffa fibers. The air temperatures to be conditioned was 40 °C, with three variations of the intake airflow velocities of 0.4, 1.1, and 1.8 m/s. According to the results of this experiment, an indirect evaporative cooler system utilizing pineapple leaf fiber as a cooling pad performs better than those employing luffa and ramie fibers as cooling pads. The maximum wet bulb effectiveness of the system using pineapple fiber was 85%, maximum dew point effectiveness was 65%, and maximum energy efficiency ratio was 52.5 Btu/W.As a passive heat exchanger, the performance of finned heat pipes is also investigated, with a maximum heat absorption of 527.6 W and a temperature reduction of 9.9 °C. |
format | Online Article Text |
id | pubmed-9816784 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-98167842023-01-07 Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad Sofia, Evi Putra, Nandy Kosasih, Engkos A. Heliyon Research Article Evaporative cooler is one of the methods that have been used to keep buildings at a comfortable temperature since ancient times. This type of cooler is particularly suitable for hot and arid areas. This research examines the design and testing of an indirect evaporative cooler system utilizing heat pipes as heat exchangers and natural fibers as cooling pads. An experiment was performed on a laboratory scale with three different types of natural fiber cooling pad materials: pineapple leaf, ramie, and luffa fibers. The air temperatures to be conditioned was 40 °C, with three variations of the intake airflow velocities of 0.4, 1.1, and 1.8 m/s. According to the results of this experiment, an indirect evaporative cooler system utilizing pineapple leaf fiber as a cooling pad performs better than those employing luffa and ramie fibers as cooling pads. The maximum wet bulb effectiveness of the system using pineapple fiber was 85%, maximum dew point effectiveness was 65%, and maximum energy efficiency ratio was 52.5 Btu/W.As a passive heat exchanger, the performance of finned heat pipes is also investigated, with a maximum heat absorption of 527.6 W and a temperature reduction of 9.9 °C. Elsevier 2022-12-23 /pmc/articles/PMC9816784/ /pubmed/36619457 http://dx.doi.org/10.1016/j.heliyon.2022.e12508 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Sofia, Evi Putra, Nandy Kosasih, Engkos A. Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
title | Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
title_full | Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
title_fullStr | Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
title_full_unstemmed | Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
title_short | Development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
title_sort | development of indirect evaporative cooler based on a finned heat pipe with a natural-fiber cooling pad |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9816784/ https://www.ncbi.nlm.nih.gov/pubmed/36619457 http://dx.doi.org/10.1016/j.heliyon.2022.e12508 |
work_keys_str_mv | AT sofiaevi developmentofindirectevaporativecoolerbasedonafinnedheatpipewithanaturalfibercoolingpad AT putranandy developmentofindirectevaporativecoolerbasedonafinnedheatpipewithanaturalfibercoolingpad AT kosasihengkosa developmentofindirectevaporativecoolerbasedonafinnedheatpipewithanaturalfibercoolingpad |