Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report
BACKGROUND: Bradycardia frequently occurs in heart-transplanted patients, mainly as a temporally restricted manifestation early after transplantation and often without symptoms. A high-degree atrioventricular block is mostly symptomatic through cerebral hypoxia induced through cerebral hypoperfusion...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9817384/ https://www.ncbi.nlm.nih.gov/pubmed/36604735 http://dx.doi.org/10.1186/s13256-022-03574-6 |
_version_ | 1784864743065911296 |
---|---|
author | Raboud, Matthieu Humm, Andrea M. Vivekanantham, Hari Suter, Philipp |
author_facet | Raboud, Matthieu Humm, Andrea M. Vivekanantham, Hari Suter, Philipp |
author_sort | Raboud, Matthieu |
collection | PubMed |
description | BACKGROUND: Bradycardia frequently occurs in heart-transplanted patients, mainly as a temporally restricted manifestation early after transplantation and often without symptoms. A high-degree atrioventricular block is mostly symptomatic through cerebral hypoxia induced through cerebral hypoperfusion. Only a few published cases show this specific electroencephalography result in this context. The purpose of this case is to bring attention to atypical manifestations of typical cardiac complications after heart transplantation and the importance of perseverance in the diagnostic. CASE PRESENTATION: A Central European man in his 50s with history of heart transplantation 31 years previously was admitted to the internal medicine ward for short-lived recurrent episodes of generalized weakness with multiple falls but without loss of consciousness. During routine electroencephalography, the patient perceived this recurrent sensation. This episode coincided with a transient third-degree atrioventricular block followed 8–10 seconds later by a generalized slowing of the electroencephalography, reflecting cerebral hypoxia due to cerebral hypoperfusion. Holter monitoring confirmed the diagnosis. A pacemaker was implanted, consequently resolving the episodes. CONCLUSION: This case report illustrates the pathophysiological central hypoxemic origin of episodes of generalized weakness caused by a high-degree atrioventricular block in a patient surviving 29 years after heart transplant. It highlights the benefit of electroencephalography as a diagnostic tool in well-selected patients. |
format | Online Article Text |
id | pubmed-9817384 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98173842023-01-07 Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report Raboud, Matthieu Humm, Andrea M. Vivekanantham, Hari Suter, Philipp J Med Case Rep Case Report BACKGROUND: Bradycardia frequently occurs in heart-transplanted patients, mainly as a temporally restricted manifestation early after transplantation and often without symptoms. A high-degree atrioventricular block is mostly symptomatic through cerebral hypoxia induced through cerebral hypoperfusion. Only a few published cases show this specific electroencephalography result in this context. The purpose of this case is to bring attention to atypical manifestations of typical cardiac complications after heart transplantation and the importance of perseverance in the diagnostic. CASE PRESENTATION: A Central European man in his 50s with history of heart transplantation 31 years previously was admitted to the internal medicine ward for short-lived recurrent episodes of generalized weakness with multiple falls but without loss of consciousness. During routine electroencephalography, the patient perceived this recurrent sensation. This episode coincided with a transient third-degree atrioventricular block followed 8–10 seconds later by a generalized slowing of the electroencephalography, reflecting cerebral hypoxia due to cerebral hypoperfusion. Holter monitoring confirmed the diagnosis. A pacemaker was implanted, consequently resolving the episodes. CONCLUSION: This case report illustrates the pathophysiological central hypoxemic origin of episodes of generalized weakness caused by a high-degree atrioventricular block in a patient surviving 29 years after heart transplant. It highlights the benefit of electroencephalography as a diagnostic tool in well-selected patients. BioMed Central 2023-01-06 /pmc/articles/PMC9817384/ /pubmed/36604735 http://dx.doi.org/10.1186/s13256-022-03574-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Case Report Raboud, Matthieu Humm, Andrea M. Vivekanantham, Hari Suter, Philipp Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
title | Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
title_full | Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
title_fullStr | Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
title_full_unstemmed | Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
title_short | Transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
title_sort | transient central hypoxemia due to intermittent high-degree atrioventricular block in a heart-transplanted patient diagnosed during routine electroencephalography: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9817384/ https://www.ncbi.nlm.nih.gov/pubmed/36604735 http://dx.doi.org/10.1186/s13256-022-03574-6 |
work_keys_str_mv | AT raboudmatthieu transientcentralhypoxemiaduetointermittenthighdegreeatrioventricularblockinahearttransplantedpatientdiagnosedduringroutineelectroencephalographyacasereport AT hummandream transientcentralhypoxemiaduetointermittenthighdegreeatrioventricularblockinahearttransplantedpatientdiagnosedduringroutineelectroencephalographyacasereport AT vivekananthamhari transientcentralhypoxemiaduetointermittenthighdegreeatrioventricularblockinahearttransplantedpatientdiagnosedduringroutineelectroencephalographyacasereport AT suterphilipp transientcentralhypoxemiaduetointermittenthighdegreeatrioventricularblockinahearttransplantedpatientdiagnosedduringroutineelectroencephalographyacasereport |