Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy
OBJECTIVE: Anatomical variations existing in cervical cancer radiotherapy treatment can be monitored by cone-beam computed tomography (CBCT) images. Deformable image registration (DIR) from planning CT (pCT) to CBCT images and synthetic CT (sCT) image generation based on CBCT are two methods for imp...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9817400/ https://www.ncbi.nlm.nih.gov/pubmed/36604687 http://dx.doi.org/10.1186/s13014-022-02191-3 |
_version_ | 1784864747133337600 |
---|---|
author | Chang, Yankui Liang, Yongguang Yang, Bo Qiu, Jie Pei, Xi Xu, Xie George |
author_facet | Chang, Yankui Liang, Yongguang Yang, Bo Qiu, Jie Pei, Xi Xu, Xie George |
author_sort | Chang, Yankui |
collection | PubMed |
description | OBJECTIVE: Anatomical variations existing in cervical cancer radiotherapy treatment can be monitored by cone-beam computed tomography (CBCT) images. Deformable image registration (DIR) from planning CT (pCT) to CBCT images and synthetic CT (sCT) image generation based on CBCT are two methods for improving the quality of CBCT images. This study aims to compare the accuracy of these two approaches geometrically and dosimetrically in cervical cancer radiotherapy. METHODS: In this study, 40 paired pCT-CBCT images were collected to evaluate the accuracy of DIR and sCT generation. The DIR method was based on a 3D multistage registration network that was trained with 150 paired pCT-CBCT images, and the sCT generation method was performed based on a 2D cycle-consistent adversarial network (CycleGAN) with 6000 paired pCT-CBCT slices for training. Then, the doses were recalculated with the CBCT, pCT, deformed pCT (dpCT) and sCT images by a GPU-based Monte Carlo dose code, ArcherQA, to obtain Dose(CBCT), Dose(pCT), Dose(dpCT) and Dose(sCT). Organs at risk (OARs) included small intestine, rectum, bladder, spinal cord, femoral heads and bone marrow, CBCT and pCT contours were delineated manually, dpCT contours were propagated through deformation vector fields, sCT contours were auto-segmented and corrected manually. RESULTS: The global gamma pass rate of Dose(sCT) and Dose(dpCT) was 99.66% ± 0.34%, while that of Dose(CBCT) and Dose(dpCT) was 85.92% ± 7.56% at the 1%/1 mm criterion and a low-dose threshold of 10%. Based on Dose(dpCT) as uniform dose distribution, there were comparable errors in femoral heads and bone marrow for the dpCT and sCT contours compared with CBCT contours, while sCT contours had lower errors in small intestine, rectum, bladder and spinal cord, especially for those with large volume difference of pCT and CBCT. CONCLUSIONS: For cervical cancer radiotherapy, the DIR method and sCT generation could produce similar precise dose distributions, but sCT contours had higher accuracy when the difference in planning CT and CBCT was large. |
format | Online Article Text |
id | pubmed-9817400 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98174002023-01-07 Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy Chang, Yankui Liang, Yongguang Yang, Bo Qiu, Jie Pei, Xi Xu, Xie George Radiat Oncol Research OBJECTIVE: Anatomical variations existing in cervical cancer radiotherapy treatment can be monitored by cone-beam computed tomography (CBCT) images. Deformable image registration (DIR) from planning CT (pCT) to CBCT images and synthetic CT (sCT) image generation based on CBCT are two methods for improving the quality of CBCT images. This study aims to compare the accuracy of these two approaches geometrically and dosimetrically in cervical cancer radiotherapy. METHODS: In this study, 40 paired pCT-CBCT images were collected to evaluate the accuracy of DIR and sCT generation. The DIR method was based on a 3D multistage registration network that was trained with 150 paired pCT-CBCT images, and the sCT generation method was performed based on a 2D cycle-consistent adversarial network (CycleGAN) with 6000 paired pCT-CBCT slices for training. Then, the doses were recalculated with the CBCT, pCT, deformed pCT (dpCT) and sCT images by a GPU-based Monte Carlo dose code, ArcherQA, to obtain Dose(CBCT), Dose(pCT), Dose(dpCT) and Dose(sCT). Organs at risk (OARs) included small intestine, rectum, bladder, spinal cord, femoral heads and bone marrow, CBCT and pCT contours were delineated manually, dpCT contours were propagated through deformation vector fields, sCT contours were auto-segmented and corrected manually. RESULTS: The global gamma pass rate of Dose(sCT) and Dose(dpCT) was 99.66% ± 0.34%, while that of Dose(CBCT) and Dose(dpCT) was 85.92% ± 7.56% at the 1%/1 mm criterion and a low-dose threshold of 10%. Based on Dose(dpCT) as uniform dose distribution, there were comparable errors in femoral heads and bone marrow for the dpCT and sCT contours compared with CBCT contours, while sCT contours had lower errors in small intestine, rectum, bladder and spinal cord, especially for those with large volume difference of pCT and CBCT. CONCLUSIONS: For cervical cancer radiotherapy, the DIR method and sCT generation could produce similar precise dose distributions, but sCT contours had higher accuracy when the difference in planning CT and CBCT was large. BioMed Central 2023-01-05 /pmc/articles/PMC9817400/ /pubmed/36604687 http://dx.doi.org/10.1186/s13014-022-02191-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Chang, Yankui Liang, Yongguang Yang, Bo Qiu, Jie Pei, Xi Xu, Xie George Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy |
title | Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy |
title_full | Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy |
title_fullStr | Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy |
title_full_unstemmed | Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy |
title_short | Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy |
title_sort | dosimetric comparison of deformable image registration and synthetic ct generation based on cbct images for organs at risk in cervical cancer radiotherapy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9817400/ https://www.ncbi.nlm.nih.gov/pubmed/36604687 http://dx.doi.org/10.1186/s13014-022-02191-3 |
work_keys_str_mv | AT changyankui dosimetriccomparisonofdeformableimageregistrationandsyntheticctgenerationbasedoncbctimagesfororgansatriskincervicalcancerradiotherapy AT liangyongguang dosimetriccomparisonofdeformableimageregistrationandsyntheticctgenerationbasedoncbctimagesfororgansatriskincervicalcancerradiotherapy AT yangbo dosimetriccomparisonofdeformableimageregistrationandsyntheticctgenerationbasedoncbctimagesfororgansatriskincervicalcancerradiotherapy AT qiujie dosimetriccomparisonofdeformableimageregistrationandsyntheticctgenerationbasedoncbctimagesfororgansatriskincervicalcancerradiotherapy AT peixi dosimetriccomparisonofdeformableimageregistrationandsyntheticctgenerationbasedoncbctimagesfororgansatriskincervicalcancerradiotherapy AT xuxiegeorge dosimetriccomparisonofdeformableimageregistrationandsyntheticctgenerationbasedoncbctimagesfororgansatriskincervicalcancerradiotherapy |