Cargando…

Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients

A rapid and sensitive isocratic ion-pair chromatographic method was developed for the accurate analysis of ternary mixtures of formoterol, tiotropium, and ciclesonide in their novel combined inhalation that is widely used for the symptomatic treatment of patients with chronic obstructive disease. An...

Descripción completa

Detalles Bibliográficos
Autores principales: Hammouda, Mohammed E. A., Salem, Yomna A., El-Ashry, Saadia M., El-Enin, Mohamed A. Abu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9818053/
https://www.ncbi.nlm.nih.gov/pubmed/36609681
http://dx.doi.org/10.1038/s41598-023-27572-w
_version_ 1784864890181124096
author Hammouda, Mohammed E. A.
Salem, Yomna A.
El-Ashry, Saadia M.
El-Enin, Mohamed A. Abu
author_facet Hammouda, Mohammed E. A.
Salem, Yomna A.
El-Ashry, Saadia M.
El-Enin, Mohamed A. Abu
author_sort Hammouda, Mohammed E. A.
collection PubMed
description A rapid and sensitive isocratic ion-pair chromatographic method was developed for the accurate analysis of ternary mixtures of formoterol, tiotropium, and ciclesonide in their novel combined inhalation that is widely used for the symptomatic treatment of patients with chronic obstructive disease. Analytical separation was performed using a C(8) column and ion pair mobile phase composed of acetonitrile: acidified deionized water (55: 45% v/v) containing 0.025% sodium dodecyl sulfate. The pH was adjusted to 3.0 using orthophosphoric acid and eluted isocratically at 2.0 mL/min and 40 °C applying UV detection at 237 nm. The calibration ranges were found to be 0.3–9.0 µg/mL for formoterol, 0.45–13.5 µg/mL for tiotropium, and 10.0–300.0 µg/mL concerning ciclesonide. The proposed method exhibited good repeatability, accuracy, and sensitivity (R.S.D. < 2.0%). The approach is rapid (run time does not exceed 15 min) and achieves satisfactory resolution (resolution factors = 7.45 and 5.3 between formoterol and tiotropium and tiotropium and ciclesonide respectively). The sensitivity and the efficiency of the proposed method permit their successful estimation with a recovery percentage ± SD of 99.33% ± 0.43 for formoterol, 99.15% ± 0.60 for tiotropium, and 99.90% ± 0.41 for ciclesonide.
format Online
Article
Text
id pubmed-9818053
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-98180532023-01-06 Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients Hammouda, Mohammed E. A. Salem, Yomna A. El-Ashry, Saadia M. El-Enin, Mohamed A. Abu Sci Rep Article A rapid and sensitive isocratic ion-pair chromatographic method was developed for the accurate analysis of ternary mixtures of formoterol, tiotropium, and ciclesonide in their novel combined inhalation that is widely used for the symptomatic treatment of patients with chronic obstructive disease. Analytical separation was performed using a C(8) column and ion pair mobile phase composed of acetonitrile: acidified deionized water (55: 45% v/v) containing 0.025% sodium dodecyl sulfate. The pH was adjusted to 3.0 using orthophosphoric acid and eluted isocratically at 2.0 mL/min and 40 °C applying UV detection at 237 nm. The calibration ranges were found to be 0.3–9.0 µg/mL for formoterol, 0.45–13.5 µg/mL for tiotropium, and 10.0–300.0 µg/mL concerning ciclesonide. The proposed method exhibited good repeatability, accuracy, and sensitivity (R.S.D. < 2.0%). The approach is rapid (run time does not exceed 15 min) and achieves satisfactory resolution (resolution factors = 7.45 and 5.3 between formoterol and tiotropium and tiotropium and ciclesonide respectively). The sensitivity and the efficiency of the proposed method permit their successful estimation with a recovery percentage ± SD of 99.33% ± 0.43 for formoterol, 99.15% ± 0.60 for tiotropium, and 99.90% ± 0.41 for ciclesonide. Nature Publishing Group UK 2023-01-06 /pmc/articles/PMC9818053/ /pubmed/36609681 http://dx.doi.org/10.1038/s41598-023-27572-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Hammouda, Mohammed E. A.
Salem, Yomna A.
El-Ashry, Saadia M.
El-Enin, Mohamed A. Abu
Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
title Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
title_full Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
title_fullStr Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
title_full_unstemmed Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
title_short Isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
title_sort isocratic ion pair chromatography for estimation of novel combined inhalation therapy that blocks coronavirus replication in chronic asthmatic patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9818053/
https://www.ncbi.nlm.nih.gov/pubmed/36609681
http://dx.doi.org/10.1038/s41598-023-27572-w
work_keys_str_mv AT hammoudamohammedea isocraticionpairchromatographyforestimationofnovelcombinedinhalationtherapythatblockscoronavirusreplicationinchronicasthmaticpatients
AT salemyomnaa isocraticionpairchromatographyforestimationofnovelcombinedinhalationtherapythatblockscoronavirusreplicationinchronicasthmaticpatients
AT elashrysaadiam isocraticionpairchromatographyforestimationofnovelcombinedinhalationtherapythatblockscoronavirusreplicationinchronicasthmaticpatients
AT eleninmohamedaabu isocraticionpairchromatographyforestimationofnovelcombinedinhalationtherapythatblockscoronavirusreplicationinchronicasthmaticpatients