A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T

Loop-mediated isothermal amplification is a promising candidate for the rapid detection of Mycobacterium tuberculosis. However, the high potential for carry-over contamination is the main obstacle to its routine use. Here, a closed tube LAMP was intended for the visual detection of Mtb to compare tu...

Descripción completa

Detalles Bibliográficos
Autores principales: Neshani, Alireza, Zare, Hosna, Sadeghian, Hamid, Safdari, Hadi, Riahi-Zanjani, Bamdad, Aryan, Ehsan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9818645/
https://www.ncbi.nlm.nih.gov/pubmed/36611447
http://dx.doi.org/10.3390/diagnostics13010155
_version_ 1784865036710182912
author Neshani, Alireza
Zare, Hosna
Sadeghian, Hamid
Safdari, Hadi
Riahi-Zanjani, Bamdad
Aryan, Ehsan
author_facet Neshani, Alireza
Zare, Hosna
Sadeghian, Hamid
Safdari, Hadi
Riahi-Zanjani, Bamdad
Aryan, Ehsan
author_sort Neshani, Alireza
collection PubMed
description Loop-mediated isothermal amplification is a promising candidate for the rapid detection of Mycobacterium tuberculosis. However, the high potential for carry-over contamination is the main obstacle to its routine use. Here, a closed tube LAMP was intended for the visual detection of Mtb to compare turbidimetric and two more favorable colorimetric methods using calcein and hydroxy naphthol blue (HNB). Additionally, a less studied dye (i.e., eriochrome black T (EBT)) was optimized in detail in the reaction for the first time. Mtb purified DNA and 30 clinical specimens were used to respectively determine the analytical and diagnostic sensitivities of each method. The turbidimetric method resulted in the best analytical sensitivity (100 fg DNA/reaction), diagnostic sensitivity and specificity (100%), and time-to-positivity of the test (15 min). However, this method is highly prone to subjective error in reading the results. Moreover, HNB-, calcein-, and EBT-LAMP could respectively detect 100 fg, 1 pg, and 1 pg DNA/reaction (the analytical sensitivities) in 30, 15, and 30 min, while the diagnostic sensitivity and specificity were respectively 93.3% and 100% for them all. Interestingly, EBT-LAMP showed the lowest potential for subjective error in reading the results. This report helps judiciously choose the most appropriate visual method, taking a step forward toward the field applicability of LAMP for the detection of Mtb, particularly in resource-limited settings.
format Online
Article
Text
id pubmed-9818645
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98186452023-01-07 A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T Neshani, Alireza Zare, Hosna Sadeghian, Hamid Safdari, Hadi Riahi-Zanjani, Bamdad Aryan, Ehsan Diagnostics (Basel) Article Loop-mediated isothermal amplification is a promising candidate for the rapid detection of Mycobacterium tuberculosis. However, the high potential for carry-over contamination is the main obstacle to its routine use. Here, a closed tube LAMP was intended for the visual detection of Mtb to compare turbidimetric and two more favorable colorimetric methods using calcein and hydroxy naphthol blue (HNB). Additionally, a less studied dye (i.e., eriochrome black T (EBT)) was optimized in detail in the reaction for the first time. Mtb purified DNA and 30 clinical specimens were used to respectively determine the analytical and diagnostic sensitivities of each method. The turbidimetric method resulted in the best analytical sensitivity (100 fg DNA/reaction), diagnostic sensitivity and specificity (100%), and time-to-positivity of the test (15 min). However, this method is highly prone to subjective error in reading the results. Moreover, HNB-, calcein-, and EBT-LAMP could respectively detect 100 fg, 1 pg, and 1 pg DNA/reaction (the analytical sensitivities) in 30, 15, and 30 min, while the diagnostic sensitivity and specificity were respectively 93.3% and 100% for them all. Interestingly, EBT-LAMP showed the lowest potential for subjective error in reading the results. This report helps judiciously choose the most appropriate visual method, taking a step forward toward the field applicability of LAMP for the detection of Mtb, particularly in resource-limited settings. MDPI 2023-01-02 /pmc/articles/PMC9818645/ /pubmed/36611447 http://dx.doi.org/10.3390/diagnostics13010155 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Neshani, Alireza
Zare, Hosna
Sadeghian, Hamid
Safdari, Hadi
Riahi-Zanjani, Bamdad
Aryan, Ehsan
A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T
title A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T
title_full A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T
title_fullStr A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T
title_full_unstemmed A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T
title_short A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification: Shedding Light on the Use of Eriochrome Black T
title_sort comparative study on visual detection of mycobacterium tuberculosis by closed tube loop-mediated isothermal amplification: shedding light on the use of eriochrome black t
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9818645/
https://www.ncbi.nlm.nih.gov/pubmed/36611447
http://dx.doi.org/10.3390/diagnostics13010155
work_keys_str_mv AT neshanialireza acomparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT zarehosna acomparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT sadeghianhamid acomparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT safdarihadi acomparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT riahizanjanibamdad acomparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT aryanehsan acomparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT neshanialireza comparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT zarehosna comparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT sadeghianhamid comparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT safdarihadi comparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT riahizanjanibamdad comparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt
AT aryanehsan comparativestudyonvisualdetectionofmycobacteriumtuberculosisbyclosedtubeloopmediatedisothermalamplificationsheddinglightontheuseoferiochromeblackt