Cargando…
Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session
Background: Exercise improves the physical function of people suffering from chronic kidney disease on hemodialysis (HD). Virtual reality is a new type of intradialysis exercise that has a positive impact on physical function. Intradialysis exercise is recommended during the first 2 h, but its safet...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9818851/ https://www.ncbi.nlm.nih.gov/pubmed/36611539 http://dx.doi.org/10.3390/healthcare11010079 |
_version_ | 1784865087277760512 |
---|---|
author | García-Testal, Alicia Martínez-Olmos, Francisco José Gil-Gómez, Jose Antonio López-Tercero, Víctor Lahoz-Cano, Laura Hervás-Marín, David Cana-Poyatos, Alicia García-Maset, Rafael Royo-Maicas, Pilar Segura-Ortí, Eva |
author_facet | García-Testal, Alicia Martínez-Olmos, Francisco José Gil-Gómez, Jose Antonio López-Tercero, Víctor Lahoz-Cano, Laura Hervás-Marín, David Cana-Poyatos, Alicia García-Maset, Rafael Royo-Maicas, Pilar Segura-Ortí, Eva |
author_sort | García-Testal, Alicia |
collection | PubMed |
description | Background: Exercise improves the physical function of people suffering from chronic kidney disease on hemodialysis (HD). Virtual reality is a new type of intradialysis exercise that has a positive impact on physical function. Intradialysis exercise is recommended during the first 2 h, but its safety in the last part of the dialysis session is unknown. Methods: This was a pilot sub-study of a clinical trial. Several hemodynamic control variables were recorded, including blood pressure, heart rate, and intradialytic hypotensive events. These variables were recorded during three different HD sessions, one HD session at rest, another HD session with exercise during the first two hours, and one HD session with exercise during the last 30 min of dialysis. The intradialysis virtual reality exercise was performed for a maximum of 30 min. Results: During exercise sessions, there was a significant increase in heart rate (6.65 (4.92, 8.39) bpm; p < 0.001) and systolic blood pressure (6.25 (0.04,12.47) mmHg; p < 0.05). There was no difference in hemodynamic control between the sessions with exercise during the first two hours and the sessions with exercise during the last 30 min. There was no association between intra-dialytic hypotensive events at rest (five events) or exercise at any point (two vs. one event(s), respectively). Conclusion: performing exercise with virtual reality at the end of a hemodialysis session is not associated with hemodynamic instability. |
format | Online Article Text |
id | pubmed-9818851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98188512023-01-07 Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session García-Testal, Alicia Martínez-Olmos, Francisco José Gil-Gómez, Jose Antonio López-Tercero, Víctor Lahoz-Cano, Laura Hervás-Marín, David Cana-Poyatos, Alicia García-Maset, Rafael Royo-Maicas, Pilar Segura-Ortí, Eva Healthcare (Basel) Article Background: Exercise improves the physical function of people suffering from chronic kidney disease on hemodialysis (HD). Virtual reality is a new type of intradialysis exercise that has a positive impact on physical function. Intradialysis exercise is recommended during the first 2 h, but its safety in the last part of the dialysis session is unknown. Methods: This was a pilot sub-study of a clinical trial. Several hemodynamic control variables were recorded, including blood pressure, heart rate, and intradialytic hypotensive events. These variables were recorded during three different HD sessions, one HD session at rest, another HD session with exercise during the first two hours, and one HD session with exercise during the last 30 min of dialysis. The intradialysis virtual reality exercise was performed for a maximum of 30 min. Results: During exercise sessions, there was a significant increase in heart rate (6.65 (4.92, 8.39) bpm; p < 0.001) and systolic blood pressure (6.25 (0.04,12.47) mmHg; p < 0.05). There was no difference in hemodynamic control between the sessions with exercise during the first two hours and the sessions with exercise during the last 30 min. There was no association between intra-dialytic hypotensive events at rest (five events) or exercise at any point (two vs. one event(s), respectively). Conclusion: performing exercise with virtual reality at the end of a hemodialysis session is not associated with hemodynamic instability. MDPI 2022-12-27 /pmc/articles/PMC9818851/ /pubmed/36611539 http://dx.doi.org/10.3390/healthcare11010079 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article García-Testal, Alicia Martínez-Olmos, Francisco José Gil-Gómez, Jose Antonio López-Tercero, Víctor Lahoz-Cano, Laura Hervás-Marín, David Cana-Poyatos, Alicia García-Maset, Rafael Royo-Maicas, Pilar Segura-Ortí, Eva Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session |
title | Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session |
title_full | Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session |
title_fullStr | Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session |
title_full_unstemmed | Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session |
title_short | Hemodynamic Tolerance of Virtual Reality Intradialysis Exercise Performed during the Last 30 Minutes versus the Beginning of the Hemodialysis Session |
title_sort | hemodynamic tolerance of virtual reality intradialysis exercise performed during the last 30 minutes versus the beginning of the hemodialysis session |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9818851/ https://www.ncbi.nlm.nih.gov/pubmed/36611539 http://dx.doi.org/10.3390/healthcare11010079 |
work_keys_str_mv | AT garciatestalalicia hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT martinezolmosfranciscojose hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT gilgomezjoseantonio hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT lopeztercerovictor hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT lahozcanolaura hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT hervasmarindavid hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT canapoyatosalicia hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT garciamasetrafael hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT royomaicaspilar hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession AT seguraortieva hemodynamictoleranceofvirtualrealityintradialysisexerciseperformedduringthelast30minutesversusthebeginningofthehemodialysissession |