Cargando…

Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples

Bisphenol A (BPA) is a widely produced chemical worldwide found in numerous everyday products. Its endocrine-disrupting properties and omnipresence have aroused concern and led to several restrictions on its use. These restrictions and growing public awareness about the toxicity of BPA have resulted...

Descripción completa

Detalles Bibliográficos
Autores principales: Szubartowski, Szymon, Tuzimski, Tomasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9819170/
https://www.ncbi.nlm.nih.gov/pubmed/36612618
http://dx.doi.org/10.3390/ijerph20010297
_version_ 1784865165344243712
author Szubartowski, Szymon
Tuzimski, Tomasz
author_facet Szubartowski, Szymon
Tuzimski, Tomasz
author_sort Szubartowski, Szymon
collection PubMed
description Bisphenol A (BPA) is a widely produced chemical worldwide found in numerous everyday products. Its endocrine-disrupting properties and omnipresence have aroused concern and led to several restrictions on its use. These restrictions and growing public awareness about the toxicity of BPA have resulted in market products labeled ”BPA-free”, with BPAs often being replaced by other bisphenols. This is why constant biomonitoring of bisphenol levels in various body fluids and tissues is essential. In this study, we propose the use of simple, cost-effective high-performance liquid chromatography coupled with the fluorescence detector (HPLC-FLD) method for the determination of simultaneously selected bisphenols in amniotic fluid. For the sample preparation, a fast, simple, and ”green” dispersive liquid–liquid microextraction (DLLME) method was used, achieving mean recovery values in the range of 80.9–115.9% with relative standard deviations below 12% for all analytes. Limits of quantification (LOQs) determined in the amniotic fluid matrix ranged from 6.17 to 22.72 ng/mL and were obtained from a calibration curve constructed using least-squares linear regression analysis for all cases. The presented sample preparation procedure can be easily adopted for LC-MS analysis.
format Online
Article
Text
id pubmed-9819170
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98191702023-01-07 Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples Szubartowski, Szymon Tuzimski, Tomasz Int J Environ Res Public Health Article Bisphenol A (BPA) is a widely produced chemical worldwide found in numerous everyday products. Its endocrine-disrupting properties and omnipresence have aroused concern and led to several restrictions on its use. These restrictions and growing public awareness about the toxicity of BPA have resulted in market products labeled ”BPA-free”, with BPAs often being replaced by other bisphenols. This is why constant biomonitoring of bisphenol levels in various body fluids and tissues is essential. In this study, we propose the use of simple, cost-effective high-performance liquid chromatography coupled with the fluorescence detector (HPLC-FLD) method for the determination of simultaneously selected bisphenols in amniotic fluid. For the sample preparation, a fast, simple, and ”green” dispersive liquid–liquid microextraction (DLLME) method was used, achieving mean recovery values in the range of 80.9–115.9% with relative standard deviations below 12% for all analytes. Limits of quantification (LOQs) determined in the amniotic fluid matrix ranged from 6.17 to 22.72 ng/mL and were obtained from a calibration curve constructed using least-squares linear regression analysis for all cases. The presented sample preparation procedure can be easily adopted for LC-MS analysis. MDPI 2022-12-24 /pmc/articles/PMC9819170/ /pubmed/36612618 http://dx.doi.org/10.3390/ijerph20010297 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Szubartowski, Szymon
Tuzimski, Tomasz
Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples
title Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples
title_full Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples
title_fullStr Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples
title_full_unstemmed Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples
title_short Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples
title_sort application of high-performance liquid chromatography combined with fluorescence detector and dispersive liquid–liquid microextraction to quantification of selected bisphenols in human amniotic fluid samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9819170/
https://www.ncbi.nlm.nih.gov/pubmed/36612618
http://dx.doi.org/10.3390/ijerph20010297
work_keys_str_mv AT szubartowskiszymon applicationofhighperformanceliquidchromatographycombinedwithfluorescencedetectoranddispersiveliquidliquidmicroextractiontoquantificationofselectedbisphenolsinhumanamnioticfluidsamples
AT tuzimskitomasz applicationofhighperformanceliquidchromatographycombinedwithfluorescencedetectoranddispersiveliquidliquidmicroextractiontoquantificationofselectedbisphenolsinhumanamnioticfluidsamples