Cargando…
Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy
Background: Upgrading from pacemakers to ICDs and CRTs is a difficult procedure, and often, transvenous lead extraction (TLE) is necessary for venous access. TLE is considered riskier in patients with multiple diseases. We aimed to assess the complexity, risk, and outcome of TLE among CRT and ICD ca...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9819767/ https://www.ncbi.nlm.nih.gov/pubmed/36612613 http://dx.doi.org/10.3390/ijerph20010291 |
_version_ | 1784865309207822336 |
---|---|
author | Stefańczyk, Paweł Nowosielecka, Dorota Polewczyk, Anna Jacheć, Wojciech Głowniak, Andrzej Kosior, Jarosław Kutarski, Andrzej |
author_facet | Stefańczyk, Paweł Nowosielecka, Dorota Polewczyk, Anna Jacheć, Wojciech Głowniak, Andrzej Kosior, Jarosław Kutarski, Andrzej |
author_sort | Stefańczyk, Paweł |
collection | PubMed |
description | Background: Upgrading from pacemakers to ICDs and CRTs is a difficult procedure, and often, transvenous lead extraction (TLE) is necessary for venous access. TLE is considered riskier in patients with multiple diseases. We aimed to assess the complexity, risk, and outcome of TLE among CRT and ICD candidates. Methods: We analyzed clinical data from 2408 patients undergoing TLE between 2006 and 2021. There were 138 patients upgraded to CRT-D, 33 patients upgraded to CRT-P and 89 individuals upgraded to ICD versus 2148 patients undergoing TLE for other non-infectious indications. Results: The need for an upgrade was the leading indication for TLE in only 36–66% of patients. In 42.0–57.6% of patients, the upgrade procedure could be successfully done only after reestablishing access to the occluded vein. All leads were extracted in 68.1–76.4% of patients, functional leads were retained in 20.2–31.9%, non-functional leads were left in place in 0.0–1.1%, and non-functional superfluous leads were extracted in 3.6–8.4%. The long-term survival rate of patients in the CRT-upgrade group was lower (63.8%) than in the non-upgrade group (75.2%). Conclusions: Upgrading a patient from an existing pacemaker to an ICD/CRT is feasible in 100% of cases, provided that TLE is performed for venous access. Major complications of TLE at the time of device upgrade are rare and, if present do not result in death. |
format | Online Article Text |
id | pubmed-9819767 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98197672023-01-07 Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy Stefańczyk, Paweł Nowosielecka, Dorota Polewczyk, Anna Jacheć, Wojciech Głowniak, Andrzej Kosior, Jarosław Kutarski, Andrzej Int J Environ Res Public Health Article Background: Upgrading from pacemakers to ICDs and CRTs is a difficult procedure, and often, transvenous lead extraction (TLE) is necessary for venous access. TLE is considered riskier in patients with multiple diseases. We aimed to assess the complexity, risk, and outcome of TLE among CRT and ICD candidates. Methods: We analyzed clinical data from 2408 patients undergoing TLE between 2006 and 2021. There were 138 patients upgraded to CRT-D, 33 patients upgraded to CRT-P and 89 individuals upgraded to ICD versus 2148 patients undergoing TLE for other non-infectious indications. Results: The need for an upgrade was the leading indication for TLE in only 36–66% of patients. In 42.0–57.6% of patients, the upgrade procedure could be successfully done only after reestablishing access to the occluded vein. All leads were extracted in 68.1–76.4% of patients, functional leads were retained in 20.2–31.9%, non-functional leads were left in place in 0.0–1.1%, and non-functional superfluous leads were extracted in 3.6–8.4%. The long-term survival rate of patients in the CRT-upgrade group was lower (63.8%) than in the non-upgrade group (75.2%). Conclusions: Upgrading a patient from an existing pacemaker to an ICD/CRT is feasible in 100% of cases, provided that TLE is performed for venous access. Major complications of TLE at the time of device upgrade are rare and, if present do not result in death. MDPI 2022-12-24 /pmc/articles/PMC9819767/ /pubmed/36612613 http://dx.doi.org/10.3390/ijerph20010291 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Stefańczyk, Paweł Nowosielecka, Dorota Polewczyk, Anna Jacheć, Wojciech Głowniak, Andrzej Kosior, Jarosław Kutarski, Andrzej Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy |
title | Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy |
title_full | Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy |
title_fullStr | Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy |
title_full_unstemmed | Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy |
title_short | Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy |
title_sort | efficacy and safety of transvenous lead extraction at the time of upgrade from pacemakers to cardioverter-defibrillators and cardiac resynchronization therapy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9819767/ https://www.ncbi.nlm.nih.gov/pubmed/36612613 http://dx.doi.org/10.3390/ijerph20010291 |
work_keys_str_mv | AT stefanczykpaweł efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy AT nowosieleckadorota efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy AT polewczykanna efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy AT jachecwojciech efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy AT głowniakandrzej efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy AT kosiorjarosław efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy AT kutarskiandrzej efficacyandsafetyoftransvenousleadextractionatthetimeofupgradefrompacemakerstocardioverterdefibrillatorsandcardiacresynchronizationtherapy |