Cargando…
Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling
11-Oxygenated androgens (11-OAs) are being discussed as potential biomarkers in diagnosis and therapy control of disorders with androgen excess such as congenital adrenal hyperplasia and polycystic ovary syndrome. However, quantification of 11-OAs by liquid chromatography-tandem mass spectrometry (L...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9820169/ https://www.ncbi.nlm.nih.gov/pubmed/36613983 http://dx.doi.org/10.3390/ijms24010539 |
_version_ | 1784865403840757760 |
---|---|
author | Zeidler, Robert Biemann, Ronald Ceglarek, Uta Kratzsch, Jürgen Isermann, Berend Gaudl, Alexander |
author_facet | Zeidler, Robert Biemann, Ronald Ceglarek, Uta Kratzsch, Jürgen Isermann, Berend Gaudl, Alexander |
author_sort | Zeidler, Robert |
collection | PubMed |
description | 11-Oxygenated androgens (11-OAs) are being discussed as potential biomarkers in diagnosis and therapy control of disorders with androgen excess such as congenital adrenal hyperplasia and polycystic ovary syndrome. However, quantification of 11-OAs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) still relies on extensive sample preparation including liquid–liquid extraction, derivatization and partial long runtimes, which is unsuitable for high-throughput analysis under routine laboratory settings. For the first time, an established online-solid-phase extraction-LC-MS/MS (online-SPE-LC-MS/MS) method for the quantitation of seven serum steroids in daily routine use was extended and validated to include 11-ketoandrostenedione, 11-ketotestosterone, 11β-hydroxyandrostenedione and 11β-hydroxytestosterone. Combining a simple protein precipitation step with fast chromatographic separation and ammonium fluoride-modified ionization resulted in a high-throughput method (6.6 min run time) featuring lower limits of quantification well below endogenous ranges (63–320 pmol/L) with recoveries between 85% and 117% (CVs ≤ 15%). Furthermore, the ability of this method to distinguish between adrenal and gonadal androgens was shown by comparing 11-OAs in patients with hyperandrogenemia to healthy controls. Due to the single shot multiplex design of the method, potential clinically relevant ratios of 11-OAs and corresponding androgens were readily available. The fully validated method covering endogenous concentration levels is ready to investigate the diagnostic values of 11-OAs in prospective studies and clinical applications. |
format | Online Article Text |
id | pubmed-9820169 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98201692023-01-07 Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling Zeidler, Robert Biemann, Ronald Ceglarek, Uta Kratzsch, Jürgen Isermann, Berend Gaudl, Alexander Int J Mol Sci Article 11-Oxygenated androgens (11-OAs) are being discussed as potential biomarkers in diagnosis and therapy control of disorders with androgen excess such as congenital adrenal hyperplasia and polycystic ovary syndrome. However, quantification of 11-OAs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) still relies on extensive sample preparation including liquid–liquid extraction, derivatization and partial long runtimes, which is unsuitable for high-throughput analysis under routine laboratory settings. For the first time, an established online-solid-phase extraction-LC-MS/MS (online-SPE-LC-MS/MS) method for the quantitation of seven serum steroids in daily routine use was extended and validated to include 11-ketoandrostenedione, 11-ketotestosterone, 11β-hydroxyandrostenedione and 11β-hydroxytestosterone. Combining a simple protein precipitation step with fast chromatographic separation and ammonium fluoride-modified ionization resulted in a high-throughput method (6.6 min run time) featuring lower limits of quantification well below endogenous ranges (63–320 pmol/L) with recoveries between 85% and 117% (CVs ≤ 15%). Furthermore, the ability of this method to distinguish between adrenal and gonadal androgens was shown by comparing 11-OAs in patients with hyperandrogenemia to healthy controls. Due to the single shot multiplex design of the method, potential clinically relevant ratios of 11-OAs and corresponding androgens were readily available. The fully validated method covering endogenous concentration levels is ready to investigate the diagnostic values of 11-OAs in prospective studies and clinical applications. MDPI 2022-12-29 /pmc/articles/PMC9820169/ /pubmed/36613983 http://dx.doi.org/10.3390/ijms24010539 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zeidler, Robert Biemann, Ronald Ceglarek, Uta Kratzsch, Jürgen Isermann, Berend Gaudl, Alexander Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling |
title | Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling |
title_full | Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling |
title_fullStr | Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling |
title_full_unstemmed | Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling |
title_short | Inclusion of 11-Oxygenated Androgens in a Clinical Routine LC-MS/MS Setup for Steroid Hormone Profiling |
title_sort | inclusion of 11-oxygenated androgens in a clinical routine lc-ms/ms setup for steroid hormone profiling |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9820169/ https://www.ncbi.nlm.nih.gov/pubmed/36613983 http://dx.doi.org/10.3390/ijms24010539 |
work_keys_str_mv | AT zeidlerrobert inclusionof11oxygenatedandrogensinaclinicalroutinelcmsmssetupforsteroidhormoneprofiling AT biemannronald inclusionof11oxygenatedandrogensinaclinicalroutinelcmsmssetupforsteroidhormoneprofiling AT ceglarekuta inclusionof11oxygenatedandrogensinaclinicalroutinelcmsmssetupforsteroidhormoneprofiling AT kratzschjurgen inclusionof11oxygenatedandrogensinaclinicalroutinelcmsmssetupforsteroidhormoneprofiling AT isermannberend inclusionof11oxygenatedandrogensinaclinicalroutinelcmsmssetupforsteroidhormoneprofiling AT gaudlalexander inclusionof11oxygenatedandrogensinaclinicalroutinelcmsmssetupforsteroidhormoneprofiling |