Cargando…
A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy
The fatigue damage assessment of laser-repaired components is critical to their service safety. However, since laser repairing is an advanced green remanufacturing technology, the current research on its fatigue mechanical behavior and fatigue damage evaluation methods is still immature. In addition...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821317/ https://www.ncbi.nlm.nih.gov/pubmed/36614384 http://dx.doi.org/10.3390/ma16010047 |
_version_ | 1784865667921477632 |
---|---|
author | Zhao, Jianyu Geng, Chuanqing Xie, Huimin Liu, Fei |
author_facet | Zhao, Jianyu Geng, Chuanqing Xie, Huimin Liu, Fei |
author_sort | Zhao, Jianyu |
collection | PubMed |
description | The fatigue damage assessment of laser-repaired components is critical to their service safety. However, since laser repairing is an advanced green remanufacturing technology, the current research on its fatigue mechanical behavior and fatigue damage evaluation methods is still immature. In addition, the relevant models used for the fatigue damage evaluation can only indicate the fatigue limit of components, which cannot describe the damage accumulation process of the components during the fatigue testing. Therefore, there is an urgent need to develop a fatigue damage evaluation method that can describe the fatigue damage accumulation and evolution to reveal the damage evolution mechanism during the fatigue test. In this study, based on the 3D-DIC technique, new damage parameters, i.e., strain average value and strain standard deviation, are proposed to quantitatively describe the damage status of the nickel-based components during the stress-based fatigue process. Then, based on the new damage parameters, a strain average value/strain standard deviation damage curve method is proposed to describe the damage status evolution of the components during the fatigue testing and evaluate its fatigue damage. For example, in the tensile fatigue test, the strain average value/strain standard deviation damage curves of the substrate component and the laser-repaired component can be divided into two damage stages. In the first damage stage, the damage increases slowly with the increase in the cycle number, whereas in the second damage stage, the damage increases rapidly with the increase in the cycle number. At this time, there is a demarcation point between the first damage stage and second damage stage in the strain average value damage curve and strain standard deviation damage curve. The cycle number of the demarcation point can be used as a reference value for the fatigue failure of the laser-repaired component. In addition, the electron backscatter diffraction (EBSD) technique was used to verify the validity of the evaluation results from the novel damage parameters. |
format | Online Article Text |
id | pubmed-9821317 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98213172023-01-07 A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy Zhao, Jianyu Geng, Chuanqing Xie, Huimin Liu, Fei Materials (Basel) Article The fatigue damage assessment of laser-repaired components is critical to their service safety. However, since laser repairing is an advanced green remanufacturing technology, the current research on its fatigue mechanical behavior and fatigue damage evaluation methods is still immature. In addition, the relevant models used for the fatigue damage evaluation can only indicate the fatigue limit of components, which cannot describe the damage accumulation process of the components during the fatigue testing. Therefore, there is an urgent need to develop a fatigue damage evaluation method that can describe the fatigue damage accumulation and evolution to reveal the damage evolution mechanism during the fatigue test. In this study, based on the 3D-DIC technique, new damage parameters, i.e., strain average value and strain standard deviation, are proposed to quantitatively describe the damage status of the nickel-based components during the stress-based fatigue process. Then, based on the new damage parameters, a strain average value/strain standard deviation damage curve method is proposed to describe the damage status evolution of the components during the fatigue testing and evaluate its fatigue damage. For example, in the tensile fatigue test, the strain average value/strain standard deviation damage curves of the substrate component and the laser-repaired component can be divided into two damage stages. In the first damage stage, the damage increases slowly with the increase in the cycle number, whereas in the second damage stage, the damage increases rapidly with the increase in the cycle number. At this time, there is a demarcation point between the first damage stage and second damage stage in the strain average value damage curve and strain standard deviation damage curve. The cycle number of the demarcation point can be used as a reference value for the fatigue failure of the laser-repaired component. In addition, the electron backscatter diffraction (EBSD) technique was used to verify the validity of the evaluation results from the novel damage parameters. MDPI 2022-12-21 /pmc/articles/PMC9821317/ /pubmed/36614384 http://dx.doi.org/10.3390/ma16010047 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Jianyu Geng, Chuanqing Xie, Huimin Liu, Fei A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy |
title | A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy |
title_full | A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy |
title_fullStr | A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy |
title_full_unstemmed | A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy |
title_short | A Novel Parameter for Fatigue Damage Assessment of Laser-Repaired Nickel-Based Alloy |
title_sort | novel parameter for fatigue damage assessment of laser-repaired nickel-based alloy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821317/ https://www.ncbi.nlm.nih.gov/pubmed/36614384 http://dx.doi.org/10.3390/ma16010047 |
work_keys_str_mv | AT zhaojianyu anovelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT gengchuanqing anovelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT xiehuimin anovelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT liufei anovelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT zhaojianyu novelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT gengchuanqing novelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT xiehuimin novelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy AT liufei novelparameterforfatiguedamageassessmentoflaserrepairednickelbasedalloy |