Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care
Loop-mediated isothermal amplification (LAMP) is the most popular technology for point-of-care testing applications due its rapid, sensitive and specific detection with simple instrumentation compared to PCR-based methods. Many systems for reading the results of LAMP amplifications exist, including...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821331/ https://www.ncbi.nlm.nih.gov/pubmed/36614336 http://dx.doi.org/10.3390/ijms24010893 |
_version_ | 1784865671091322880 |
---|---|
author | Crego-Vicente, Beatriz Fernández-Soto, Pedro García-Bernalt Diego, Juan Febrer-Sendra, Begoña Muro, Antonio |
author_facet | Crego-Vicente, Beatriz Fernández-Soto, Pedro García-Bernalt Diego, Juan Febrer-Sendra, Begoña Muro, Antonio |
author_sort | Crego-Vicente, Beatriz |
collection | PubMed |
description | Loop-mediated isothermal amplification (LAMP) is the most popular technology for point-of-care testing applications due its rapid, sensitive and specific detection with simple instrumentation compared to PCR-based methods. Many systems for reading the results of LAMP amplifications exist, including real-time fluorescence detection using fluorophore-labelled probes attached to oligonucleotide sequences complementary to the target nucleic acid. This methodology allows the simultaneous detection of multiple targets (multiplexing) in one LAMP assay. A method for multiplexing LAMP is the amplification by release of quenching (DARQ) technique by using a 5′-quencher modified LAMP primer annealed to 3′-fluorophore-labelled acting as detection oligonucleotide. The main application of multiplex LAMP is the rapid and accurate diagnosis of infectious diseases, allowing differentiation of co-infecting pathogens in a single reaction. Schistosomiasis, caused among other species by Schistosoma mansoni and strongyloidiasis, caused by Strongyloides stercoralis, are the most common helminth-parasite infections worldwide with overlapping distribution areas and high possibility of coinfections in the human population. It would be of great interest to develop a duplex LAMP to detect both pathogens in the same reaction. In this study, we investigate the use of our two previously developed and well-stablished LAMP assays for S. mansoni and Strongyloides spp. DNA detection in a new duplex real-time eight-primer system based on a modified DARQ probe method that can be performed in a portable isothermal fluorimeter with minimal laboratory resources. We also applied a strategy to stabilize the duplexed DARQ-LAMP mixtures at room temperature for use as ready-to-use formats facilitating analysis in field settings as point-of-care diagnostics for schistosomiasis and strongyloidiasis. |
format | Online Article Text |
id | pubmed-9821331 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98213312023-01-07 Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care Crego-Vicente, Beatriz Fernández-Soto, Pedro García-Bernalt Diego, Juan Febrer-Sendra, Begoña Muro, Antonio Int J Mol Sci Article Loop-mediated isothermal amplification (LAMP) is the most popular technology for point-of-care testing applications due its rapid, sensitive and specific detection with simple instrumentation compared to PCR-based methods. Many systems for reading the results of LAMP amplifications exist, including real-time fluorescence detection using fluorophore-labelled probes attached to oligonucleotide sequences complementary to the target nucleic acid. This methodology allows the simultaneous detection of multiple targets (multiplexing) in one LAMP assay. A method for multiplexing LAMP is the amplification by release of quenching (DARQ) technique by using a 5′-quencher modified LAMP primer annealed to 3′-fluorophore-labelled acting as detection oligonucleotide. The main application of multiplex LAMP is the rapid and accurate diagnosis of infectious diseases, allowing differentiation of co-infecting pathogens in a single reaction. Schistosomiasis, caused among other species by Schistosoma mansoni and strongyloidiasis, caused by Strongyloides stercoralis, are the most common helminth-parasite infections worldwide with overlapping distribution areas and high possibility of coinfections in the human population. It would be of great interest to develop a duplex LAMP to detect both pathogens in the same reaction. In this study, we investigate the use of our two previously developed and well-stablished LAMP assays for S. mansoni and Strongyloides spp. DNA detection in a new duplex real-time eight-primer system based on a modified DARQ probe method that can be performed in a portable isothermal fluorimeter with minimal laboratory resources. We also applied a strategy to stabilize the duplexed DARQ-LAMP mixtures at room temperature for use as ready-to-use formats facilitating analysis in field settings as point-of-care diagnostics for schistosomiasis and strongyloidiasis. MDPI 2023-01-03 /pmc/articles/PMC9821331/ /pubmed/36614336 http://dx.doi.org/10.3390/ijms24010893 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Crego-Vicente, Beatriz Fernández-Soto, Pedro García-Bernalt Diego, Juan Febrer-Sendra, Begoña Muro, Antonio Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care |
title | Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care |
title_full | Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care |
title_fullStr | Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care |
title_full_unstemmed | Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care |
title_short | Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care |
title_sort | development of a duplex lamp assay with probe-based readout for simultaneous real-time detection of schistosoma mansoni and strongyloides spp. -a laboratory approach to point-of-care |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821331/ https://www.ncbi.nlm.nih.gov/pubmed/36614336 http://dx.doi.org/10.3390/ijms24010893 |
work_keys_str_mv | AT cregovicentebeatriz developmentofaduplexlampassaywithprobebasedreadoutforsimultaneousrealtimedetectionofschistosomamansoniandstrongyloidessppalaboratoryapproachtopointofcare AT fernandezsotopedro developmentofaduplexlampassaywithprobebasedreadoutforsimultaneousrealtimedetectionofschistosomamansoniandstrongyloidessppalaboratoryapproachtopointofcare AT garciabernaltdiegojuan developmentofaduplexlampassaywithprobebasedreadoutforsimultaneousrealtimedetectionofschistosomamansoniandstrongyloidessppalaboratoryapproachtopointofcare AT febrersendrabegona developmentofaduplexlampassaywithprobebasedreadoutforsimultaneousrealtimedetectionofschistosomamansoniandstrongyloidessppalaboratoryapproachtopointofcare AT muroantonio developmentofaduplexlampassaywithprobebasedreadoutforsimultaneousrealtimedetectionofschistosomamansoniandstrongyloidessppalaboratoryapproachtopointofcare |