Cargando…
Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study
Intramedullary nailing (IMN) is a popular treatment for elderly patients with femoral shaft fractures. Recently, prophylactic neck fixation has been increasingly used to prevent proximal femoral fractures during IMN. Therefore, this study aimed to investigate the biomechanical strength of prophylact...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821729/ https://www.ncbi.nlm.nih.gov/pubmed/36615182 http://dx.doi.org/10.3390/jcm12010383 |
_version_ | 1784865768567996416 |
---|---|
author | Park, Kyeong-Hyeon Oh, Chang-Wug Kim, Joon-Woo Kim, Hee-Jun Kim, Dong-Hyun Lee, Jin-Han Hong, Won-Ki Oh, Jong-Keon |
author_facet | Park, Kyeong-Hyeon Oh, Chang-Wug Kim, Joon-Woo Kim, Hee-Jun Kim, Dong-Hyun Lee, Jin-Han Hong, Won-Ki Oh, Jong-Keon |
author_sort | Park, Kyeong-Hyeon |
collection | PubMed |
description | Intramedullary nailing (IMN) is a popular treatment for elderly patients with femoral shaft fractures. Recently, prophylactic neck fixation has been increasingly used to prevent proximal femoral fractures during IMN. Therefore, this study aimed to investigate the biomechanical strength of prophylactic neck fixation in osteoporotic femoral fractures. An osteoporotic femur model was created to simulate the union of femoral shaft fractures with IMN. Two study groups comprising six specimens each were created for IMN with two standard proximal locking screws (SN group) and IMN with two reconstruction proximal locking screws (RN group). Axial loading was conducted to measure the stiffness, load-to-failure, and failure modes. There were no statistically significant differences in stiffness between the two groups. However, the load-to-failure in the RN group was significantly higher than that in the SN group (p < 0.05). Femoral neck fractures occurred in all specimens in the SN group. Five constructs in the RN group showed subtrochanteric fractures without femoral neck fractures. However, one construct was observed in both subtrochanteric and femoral neck fractures. Therefore, prophylactic neck fixation may be considered an alternative biomechanical solution to prevent proximal femoral fractures when performing IMN for osteoporotic femoral fractures. |
format | Online Article Text |
id | pubmed-9821729 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98217292023-01-07 Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study Park, Kyeong-Hyeon Oh, Chang-Wug Kim, Joon-Woo Kim, Hee-Jun Kim, Dong-Hyun Lee, Jin-Han Hong, Won-Ki Oh, Jong-Keon J Clin Med Article Intramedullary nailing (IMN) is a popular treatment for elderly patients with femoral shaft fractures. Recently, prophylactic neck fixation has been increasingly used to prevent proximal femoral fractures during IMN. Therefore, this study aimed to investigate the biomechanical strength of prophylactic neck fixation in osteoporotic femoral fractures. An osteoporotic femur model was created to simulate the union of femoral shaft fractures with IMN. Two study groups comprising six specimens each were created for IMN with two standard proximal locking screws (SN group) and IMN with two reconstruction proximal locking screws (RN group). Axial loading was conducted to measure the stiffness, load-to-failure, and failure modes. There were no statistically significant differences in stiffness between the two groups. However, the load-to-failure in the RN group was significantly higher than that in the SN group (p < 0.05). Femoral neck fractures occurred in all specimens in the SN group. Five constructs in the RN group showed subtrochanteric fractures without femoral neck fractures. However, one construct was observed in both subtrochanteric and femoral neck fractures. Therefore, prophylactic neck fixation may be considered an alternative biomechanical solution to prevent proximal femoral fractures when performing IMN for osteoporotic femoral fractures. MDPI 2023-01-03 /pmc/articles/PMC9821729/ /pubmed/36615182 http://dx.doi.org/10.3390/jcm12010383 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Kyeong-Hyeon Oh, Chang-Wug Kim, Joon-Woo Kim, Hee-Jun Kim, Dong-Hyun Lee, Jin-Han Hong, Won-Ki Oh, Jong-Keon Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study |
title | Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study |
title_full | Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study |
title_fullStr | Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study |
title_full_unstemmed | Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study |
title_short | Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study |
title_sort | prophylactic femoral neck fixation in an osteoporosis femur model: a novel surgical technique with biomechanical study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821729/ https://www.ncbi.nlm.nih.gov/pubmed/36615182 http://dx.doi.org/10.3390/jcm12010383 |
work_keys_str_mv | AT parkkyeonghyeon prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT ohchangwug prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT kimjoonwoo prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT kimheejun prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT kimdonghyun prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT leejinhan prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT hongwonki prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy AT ohjongkeon prophylacticfemoralneckfixationinanosteoporosisfemurmodelanovelsurgicaltechniquewithbiomechanicalstudy |