Cargando…

Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device

In order to further promote the application of segment-assembled bridge piers in medium- and high-intensity areas, and to reduce the post-earthquake damage and repair cost of bridge piers, in this paper, a precast segmental concrete-filled steel-tube bridge pier (PSCFSTBP) with an external arched en...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chengquan, Zong, Yanwei, Zou, Yun, Shen, Yonggang, Jiang, Jiqing, Yin, Chongli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821898/
https://www.ncbi.nlm.nih.gov/pubmed/36614679
http://dx.doi.org/10.3390/ma16010340
_version_ 1784865811838533632
author Wang, Chengquan
Zong, Yanwei
Zou, Yun
Shen, Yonggang
Jiang, Jiqing
Yin, Chongli
author_facet Wang, Chengquan
Zong, Yanwei
Zou, Yun
Shen, Yonggang
Jiang, Jiqing
Yin, Chongli
author_sort Wang, Chengquan
collection PubMed
description In order to further promote the application of segment-assembled bridge piers in medium- and high-intensity areas, and to reduce the post-earthquake damage and repair cost of bridge piers, in this paper, a precast segmental concrete-filled steel-tube bridge pier (PSCFSTBP) with an external arched energy dissipation device (AEDD) is proposed. Firstly, the effectiveness of the finite-element analysis software ABAQUS 6.14-4 is proved by the test results of the PSCFSTBP and the corresponding finite-element model analysis results. Secondly, ABAQUS 6.14-4 was used to establish four-segment PSCFSTBP models with four different structural forms (non-energy dissipation device, external arch steel plate, external vertical steel plate, and external AEDD), and the seismic performance of each model was compared and analyzed under reciprocating displacement loading. The results show that compared with the PSCFSTBP with an external AEDD, the lateral bearing capacity of the PSCFSTBP with an external vertical steel plate is increased by about 11.9%, and the initial stiffness is increased by about 2.5%. Compared with the PSCFSTBP with an external arch steel plate, the lateral bearing capacity, initial stiffness, and energy dissipation capacity are increased by 28.8%, 4.6%, and 13 times, respectively. Compared with the PSCFSTBP without an energy dissipation device, its lateral bearing capacity, initial stiffness, and energy dissipation capacity are increased by 39.4%, 10.4%, and 18 times, respectively. The residual displacement of the PSCFSTBP with an external AEDD is kept within 1 mm in the whole displacement loading stage, the offset rate is less than 1%, and the pier damage is controllable, which can realize rapid repair after an earthquake. Finally, the multi-level energy consumption and local replacement of the AEDD are also explored.
format Online
Article
Text
id pubmed-9821898
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98218982023-01-07 Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device Wang, Chengquan Zong, Yanwei Zou, Yun Shen, Yonggang Jiang, Jiqing Yin, Chongli Materials (Basel) Article In order to further promote the application of segment-assembled bridge piers in medium- and high-intensity areas, and to reduce the post-earthquake damage and repair cost of bridge piers, in this paper, a precast segmental concrete-filled steel-tube bridge pier (PSCFSTBP) with an external arched energy dissipation device (AEDD) is proposed. Firstly, the effectiveness of the finite-element analysis software ABAQUS 6.14-4 is proved by the test results of the PSCFSTBP and the corresponding finite-element model analysis results. Secondly, ABAQUS 6.14-4 was used to establish four-segment PSCFSTBP models with four different structural forms (non-energy dissipation device, external arch steel plate, external vertical steel plate, and external AEDD), and the seismic performance of each model was compared and analyzed under reciprocating displacement loading. The results show that compared with the PSCFSTBP with an external AEDD, the lateral bearing capacity of the PSCFSTBP with an external vertical steel plate is increased by about 11.9%, and the initial stiffness is increased by about 2.5%. Compared with the PSCFSTBP with an external arch steel plate, the lateral bearing capacity, initial stiffness, and energy dissipation capacity are increased by 28.8%, 4.6%, and 13 times, respectively. Compared with the PSCFSTBP without an energy dissipation device, its lateral bearing capacity, initial stiffness, and energy dissipation capacity are increased by 39.4%, 10.4%, and 18 times, respectively. The residual displacement of the PSCFSTBP with an external AEDD is kept within 1 mm in the whole displacement loading stage, the offset rate is less than 1%, and the pier damage is controllable, which can realize rapid repair after an earthquake. Finally, the multi-level energy consumption and local replacement of the AEDD are also explored. MDPI 2022-12-29 /pmc/articles/PMC9821898/ /pubmed/36614679 http://dx.doi.org/10.3390/ma16010340 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Chengquan
Zong, Yanwei
Zou, Yun
Shen, Yonggang
Jiang, Jiqing
Yin, Chongli
Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device
title Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device
title_full Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device
title_fullStr Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device
title_full_unstemmed Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device
title_short Quasistatic Analysis of Precast Segmental Concrete-Filled Steel-Tube Bridge Pier with External Arched Energy Dissipation Device
title_sort quasistatic analysis of precast segmental concrete-filled steel-tube bridge pier with external arched energy dissipation device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821898/
https://www.ncbi.nlm.nih.gov/pubmed/36614679
http://dx.doi.org/10.3390/ma16010340
work_keys_str_mv AT wangchengquan quasistaticanalysisofprecastsegmentalconcretefilledsteeltubebridgepierwithexternalarchedenergydissipationdevice
AT zongyanwei quasistaticanalysisofprecastsegmentalconcretefilledsteeltubebridgepierwithexternalarchedenergydissipationdevice
AT zouyun quasistaticanalysisofprecastsegmentalconcretefilledsteeltubebridgepierwithexternalarchedenergydissipationdevice
AT shenyonggang quasistaticanalysisofprecastsegmentalconcretefilledsteeltubebridgepierwithexternalarchedenergydissipationdevice
AT jiangjiqing quasistaticanalysisofprecastsegmentalconcretefilledsteeltubebridgepierwithexternalarchedenergydissipationdevice
AT yinchongli quasistaticanalysisofprecastsegmentalconcretefilledsteeltubebridgepierwithexternalarchedenergydissipationdevice