The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites

The new reliable sensor for pH determination was designed with the use of hydrous iridium dioxide and its composites. Three different hIrO(2)-based materials were prepared and applied as solid-contact layers in pH-selective electrodes with polymeric membrane. The material choice included standalone...

Descripción completa

Detalles Bibliográficos
Autores principales: Lenar, Nikola, Piech, Robert, Paczosa-Bator, Beata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821908/
https://www.ncbi.nlm.nih.gov/pubmed/36614531
http://dx.doi.org/10.3390/ma16010192
_version_ 1784865814891986944
author Lenar, Nikola
Piech, Robert
Paczosa-Bator, Beata
author_facet Lenar, Nikola
Piech, Robert
Paczosa-Bator, Beata
author_sort Lenar, Nikola
collection PubMed
description The new reliable sensor for pH determination was designed with the use of hydrous iridium dioxide and its composites. Three different hIrO(2)-based materials were prepared and applied as solid-contact layers in pH-selective electrodes with polymeric membrane. The material choice included standalone hydrous iridium oxide; composite material of hydrous iridium oxide, carbon nanotubes, and triple composite material composed of hydrous iridium oxide; carbon nanotubes; and poly(3-octylthiophene-2,5-diyl). The paper depicts that the addition of functional material to standalone metal oxide is beneficial for the performance of solid-state ion-selective electrodes and presents the universal approach to designing this type of sensors. Each component contributed differently to the sensors’ performance—the addition of carbon nanotubes increased the electrical capacitance of sensor (up to 400 µF) while the addition of conducting polymer allowed it to increase the contact angle of material changing its wetting properties and enhancing the stability of potentiometric response. Hydrous iridium oxide contacted electrodes exhibit linear response in wide linear range of pH (2–11) and stable potentiometric response (the lowest potential drift of 0.036 mV/h is attributed to the electrode with triple composite material).
format Online
Article
Text
id pubmed-9821908
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98219082023-01-07 The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites Lenar, Nikola Piech, Robert Paczosa-Bator, Beata Materials (Basel) Article The new reliable sensor for pH determination was designed with the use of hydrous iridium dioxide and its composites. Three different hIrO(2)-based materials were prepared and applied as solid-contact layers in pH-selective electrodes with polymeric membrane. The material choice included standalone hydrous iridium oxide; composite material of hydrous iridium oxide, carbon nanotubes, and triple composite material composed of hydrous iridium oxide; carbon nanotubes; and poly(3-octylthiophene-2,5-diyl). The paper depicts that the addition of functional material to standalone metal oxide is beneficial for the performance of solid-state ion-selective electrodes and presents the universal approach to designing this type of sensors. Each component contributed differently to the sensors’ performance—the addition of carbon nanotubes increased the electrical capacitance of sensor (up to 400 µF) while the addition of conducting polymer allowed it to increase the contact angle of material changing its wetting properties and enhancing the stability of potentiometric response. Hydrous iridium oxide contacted electrodes exhibit linear response in wide linear range of pH (2–11) and stable potentiometric response (the lowest potential drift of 0.036 mV/h is attributed to the electrode with triple composite material). MDPI 2022-12-25 /pmc/articles/PMC9821908/ /pubmed/36614531 http://dx.doi.org/10.3390/ma16010192 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lenar, Nikola
Piech, Robert
Paczosa-Bator, Beata
The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites
title The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites
title_full The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites
title_fullStr The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites
title_full_unstemmed The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites
title_short The New Reliable pH Sensor Based on Hydrous Iridium Dioxide and Its Composites
title_sort new reliable ph sensor based on hydrous iridium dioxide and its composites
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9821908/
https://www.ncbi.nlm.nih.gov/pubmed/36614531
http://dx.doi.org/10.3390/ma16010192
work_keys_str_mv AT lenarnikola thenewreliablephsensorbasedonhydrousiridiumdioxideanditscomposites
AT piechrobert thenewreliablephsensorbasedonhydrousiridiumdioxideanditscomposites
AT paczosabatorbeata thenewreliablephsensorbasedonhydrousiridiumdioxideanditscomposites
AT lenarnikola newreliablephsensorbasedonhydrousiridiumdioxideanditscomposites
AT piechrobert newreliablephsensorbasedonhydrousiridiumdioxideanditscomposites
AT paczosabatorbeata newreliablephsensorbasedonhydrousiridiumdioxideanditscomposites