Cargando…

High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS

This paper presents two devices to detect the liquid dielectric characterization. The differential method was used to enhance the robustness and reduce tolerance. A basic sensor based on defected ground structure (DGS) was designed and the optimization for the squares of the DGS via adaptive genetic...

Descripción completa

Detalles Bibliográficos
Autores principales: Xie, Bingfang, Gao, Zhiqiang, Wang, Cong, Ali, Luqman, Muhammad, Azeem, Meng, Fanyi, Qian, Cheng, Ding, Xumin, Adhikari, Kishor Kumar, Wu, Qun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9823319/
https://www.ncbi.nlm.nih.gov/pubmed/36616970
http://dx.doi.org/10.3390/s23010372
_version_ 1784866130465128448
author Xie, Bingfang
Gao, Zhiqiang
Wang, Cong
Ali, Luqman
Muhammad, Azeem
Meng, Fanyi
Qian, Cheng
Ding, Xumin
Adhikari, Kishor Kumar
Wu, Qun
author_facet Xie, Bingfang
Gao, Zhiqiang
Wang, Cong
Ali, Luqman
Muhammad, Azeem
Meng, Fanyi
Qian, Cheng
Ding, Xumin
Adhikari, Kishor Kumar
Wu, Qun
author_sort Xie, Bingfang
collection PubMed
description This paper presents two devices to detect the liquid dielectric characterization. The differential method was used to enhance the robustness and reduce tolerance. A basic sensor based on defected ground structure (DGS) was designed and the optimization for the squares of the DGS via adaptive genetic algorithm was applied to enhance the performance of the microwave sensor, which was shown by the difference of the two resonant frequencies. Furthermore, the electric field distribution was enhanced. Glass microcapillary tubes were used to hold samples to provide an environment of non-invasive. The optimized device exhibited the sensitivity of 0.076, which is more than 1.52 times than the basic structure. It could be considered a sensitive and robust sensor with quick response time for liquid dielectric characterization.
format Online
Article
Text
id pubmed-9823319
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98233192023-01-08 High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS Xie, Bingfang Gao, Zhiqiang Wang, Cong Ali, Luqman Muhammad, Azeem Meng, Fanyi Qian, Cheng Ding, Xumin Adhikari, Kishor Kumar Wu, Qun Sensors (Basel) Communication This paper presents two devices to detect the liquid dielectric characterization. The differential method was used to enhance the robustness and reduce tolerance. A basic sensor based on defected ground structure (DGS) was designed and the optimization for the squares of the DGS via adaptive genetic algorithm was applied to enhance the performance of the microwave sensor, which was shown by the difference of the two resonant frequencies. Furthermore, the electric field distribution was enhanced. Glass microcapillary tubes were used to hold samples to provide an environment of non-invasive. The optimized device exhibited the sensitivity of 0.076, which is more than 1.52 times than the basic structure. It could be considered a sensitive and robust sensor with quick response time for liquid dielectric characterization. MDPI 2022-12-29 /pmc/articles/PMC9823319/ /pubmed/36616970 http://dx.doi.org/10.3390/s23010372 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Xie, Bingfang
Gao, Zhiqiang
Wang, Cong
Ali, Luqman
Muhammad, Azeem
Meng, Fanyi
Qian, Cheng
Ding, Xumin
Adhikari, Kishor Kumar
Wu, Qun
High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS
title High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS
title_full High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS
title_fullStr High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS
title_full_unstemmed High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS
title_short High-Sensitivity Liquid Dielectric Characterization Differential Sensor by 1-Bit Coding DGS
title_sort high-sensitivity liquid dielectric characterization differential sensor by 1-bit coding dgs
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9823319/
https://www.ncbi.nlm.nih.gov/pubmed/36616970
http://dx.doi.org/10.3390/s23010372
work_keys_str_mv AT xiebingfang highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT gaozhiqiang highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT wangcong highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT aliluqman highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT muhammadazeem highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT mengfanyi highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT qiancheng highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT dingxumin highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT adhikarikishorkumar highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs
AT wuqun highsensitivityliquiddielectriccharacterizationdifferentialsensorby1bitcodingdgs