Cargando…
Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
Given the labor-consuming nature of model establishment, model transfer has become a considerable topic in the study of near-infrared (NIR) spectroscopy. Recently, many new algorithms have been proposed for the model transfer of spectra collected by the same types of instruments under different situ...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9823907/ https://www.ncbi.nlm.nih.gov/pubmed/36615595 http://dx.doi.org/10.3390/molecules28010406 |
_version_ | 1784866278297567232 |
---|---|
author | Zhang, Hui Tan, Haining Lin, Boran Yang, Xiangchun Sun, Zhongyu Zhong, Liang Gao, Lele Li, Lian Dong, Qin Nie, Lei Zang, Hengchang |
author_facet | Zhang, Hui Tan, Haining Lin, Boran Yang, Xiangchun Sun, Zhongyu Zhong, Liang Gao, Lele Li, Lian Dong, Qin Nie, Lei Zang, Hengchang |
author_sort | Zhang, Hui |
collection | PubMed |
description | Given the labor-consuming nature of model establishment, model transfer has become a considerable topic in the study of near-infrared (NIR) spectroscopy. Recently, many new algorithms have been proposed for the model transfer of spectra collected by the same types of instruments under different situations. However, in a practical scenario, we need to deal with model transfer between different types of instruments. To expand model applicability, we must develop a method that could transfer spectra acquired from different types of NIR spectrometers with different wavenumbers or absorbance. Therefore, in our study, we propose a new methodology based on improved principal component analysis (IPCA) for calibration transfer between different types of spectrometers. We adopted three datasets for method evaluation, including public pharmaceutical tablets (dataset 1), corn data (dataset 2), and the spectra of eight batches of samples acquired from the plasma ethanol precipitation process collected by FT-NIR and MicroNIR spectrometers (dataset 3). In the calibration transfer for public datasets, IPCA displayed comparable results with the classical calibration transfer method using piecewise direct standardization (PDS), indicating its obvious ability to transfer spectra collected from the same types of instruments. However, in the calibration transfer for dataset 3, our proposed IPCA method achieved a successful bi-transfer between the spectra acquired from the benchtop and micro-instruments with/without wavelength region selection. Furthermore, our proposed method enabled improvements in prediction ability rather than the degradation of the models built with original micro spectra. Therefore, our proposed method has no limitations on the spectrum for model transfer between different types of NIR instruments, thus allowing a wide application range, which could provide a supporting technology for the practical application of NIR spectroscopy. |
format | Online Article Text |
id | pubmed-9823907 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98239072023-01-08 Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers Zhang, Hui Tan, Haining Lin, Boran Yang, Xiangchun Sun, Zhongyu Zhong, Liang Gao, Lele Li, Lian Dong, Qin Nie, Lei Zang, Hengchang Molecules Article Given the labor-consuming nature of model establishment, model transfer has become a considerable topic in the study of near-infrared (NIR) spectroscopy. Recently, many new algorithms have been proposed for the model transfer of spectra collected by the same types of instruments under different situations. However, in a practical scenario, we need to deal with model transfer between different types of instruments. To expand model applicability, we must develop a method that could transfer spectra acquired from different types of NIR spectrometers with different wavenumbers or absorbance. Therefore, in our study, we propose a new methodology based on improved principal component analysis (IPCA) for calibration transfer between different types of spectrometers. We adopted three datasets for method evaluation, including public pharmaceutical tablets (dataset 1), corn data (dataset 2), and the spectra of eight batches of samples acquired from the plasma ethanol precipitation process collected by FT-NIR and MicroNIR spectrometers (dataset 3). In the calibration transfer for public datasets, IPCA displayed comparable results with the classical calibration transfer method using piecewise direct standardization (PDS), indicating its obvious ability to transfer spectra collected from the same types of instruments. However, in the calibration transfer for dataset 3, our proposed IPCA method achieved a successful bi-transfer between the spectra acquired from the benchtop and micro-instruments with/without wavelength region selection. Furthermore, our proposed method enabled improvements in prediction ability rather than the degradation of the models built with original micro spectra. Therefore, our proposed method has no limitations on the spectrum for model transfer between different types of NIR instruments, thus allowing a wide application range, which could provide a supporting technology for the practical application of NIR spectroscopy. MDPI 2023-01-03 /pmc/articles/PMC9823907/ /pubmed/36615595 http://dx.doi.org/10.3390/molecules28010406 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Hui Tan, Haining Lin, Boran Yang, Xiangchun Sun, Zhongyu Zhong, Liang Gao, Lele Li, Lian Dong, Qin Nie, Lei Zang, Hengchang Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers |
title | Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers |
title_full | Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers |
title_fullStr | Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers |
title_full_unstemmed | Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers |
title_short | Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers |
title_sort | improved principal component analysis (ipca): a novel method for quantitative calibration transfer between different near-infrared spectrometers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9823907/ https://www.ncbi.nlm.nih.gov/pubmed/36615595 http://dx.doi.org/10.3390/molecules28010406 |
work_keys_str_mv | AT zhanghui improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT tanhaining improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT linboran improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT yangxiangchun improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT sunzhongyu improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT zhongliang improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT gaolele improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT lilian improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT dongqin improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT nielei improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers AT zanghengchang improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers |