Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers

Given the labor-consuming nature of model establishment, model transfer has become a considerable topic in the study of near-infrared (NIR) spectroscopy. Recently, many new algorithms have been proposed for the model transfer of spectra collected by the same types of instruments under different situ...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Hui, Tan, Haining, Lin, Boran, Yang, Xiangchun, Sun, Zhongyu, Zhong, Liang, Gao, Lele, Li, Lian, Dong, Qin, Nie, Lei, Zang, Hengchang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9823907/
https://www.ncbi.nlm.nih.gov/pubmed/36615595
http://dx.doi.org/10.3390/molecules28010406
_version_ 1784866278297567232
author Zhang, Hui
Tan, Haining
Lin, Boran
Yang, Xiangchun
Sun, Zhongyu
Zhong, Liang
Gao, Lele
Li, Lian
Dong, Qin
Nie, Lei
Zang, Hengchang
author_facet Zhang, Hui
Tan, Haining
Lin, Boran
Yang, Xiangchun
Sun, Zhongyu
Zhong, Liang
Gao, Lele
Li, Lian
Dong, Qin
Nie, Lei
Zang, Hengchang
author_sort Zhang, Hui
collection PubMed
description Given the labor-consuming nature of model establishment, model transfer has become a considerable topic in the study of near-infrared (NIR) spectroscopy. Recently, many new algorithms have been proposed for the model transfer of spectra collected by the same types of instruments under different situations. However, in a practical scenario, we need to deal with model transfer between different types of instruments. To expand model applicability, we must develop a method that could transfer spectra acquired from different types of NIR spectrometers with different wavenumbers or absorbance. Therefore, in our study, we propose a new methodology based on improved principal component analysis (IPCA) for calibration transfer between different types of spectrometers. We adopted three datasets for method evaluation, including public pharmaceutical tablets (dataset 1), corn data (dataset 2), and the spectra of eight batches of samples acquired from the plasma ethanol precipitation process collected by FT-NIR and MicroNIR spectrometers (dataset 3). In the calibration transfer for public datasets, IPCA displayed comparable results with the classical calibration transfer method using piecewise direct standardization (PDS), indicating its obvious ability to transfer spectra collected from the same types of instruments. However, in the calibration transfer for dataset 3, our proposed IPCA method achieved a successful bi-transfer between the spectra acquired from the benchtop and micro-instruments with/without wavelength region selection. Furthermore, our proposed method enabled improvements in prediction ability rather than the degradation of the models built with original micro spectra. Therefore, our proposed method has no limitations on the spectrum for model transfer between different types of NIR instruments, thus allowing a wide application range, which could provide a supporting technology for the practical application of NIR spectroscopy.
format Online
Article
Text
id pubmed-9823907
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98239072023-01-08 Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers Zhang, Hui Tan, Haining Lin, Boran Yang, Xiangchun Sun, Zhongyu Zhong, Liang Gao, Lele Li, Lian Dong, Qin Nie, Lei Zang, Hengchang Molecules Article Given the labor-consuming nature of model establishment, model transfer has become a considerable topic in the study of near-infrared (NIR) spectroscopy. Recently, many new algorithms have been proposed for the model transfer of spectra collected by the same types of instruments under different situations. However, in a practical scenario, we need to deal with model transfer between different types of instruments. To expand model applicability, we must develop a method that could transfer spectra acquired from different types of NIR spectrometers with different wavenumbers or absorbance. Therefore, in our study, we propose a new methodology based on improved principal component analysis (IPCA) for calibration transfer between different types of spectrometers. We adopted three datasets for method evaluation, including public pharmaceutical tablets (dataset 1), corn data (dataset 2), and the spectra of eight batches of samples acquired from the plasma ethanol precipitation process collected by FT-NIR and MicroNIR spectrometers (dataset 3). In the calibration transfer for public datasets, IPCA displayed comparable results with the classical calibration transfer method using piecewise direct standardization (PDS), indicating its obvious ability to transfer spectra collected from the same types of instruments. However, in the calibration transfer for dataset 3, our proposed IPCA method achieved a successful bi-transfer between the spectra acquired from the benchtop and micro-instruments with/without wavelength region selection. Furthermore, our proposed method enabled improvements in prediction ability rather than the degradation of the models built with original micro spectra. Therefore, our proposed method has no limitations on the spectrum for model transfer between different types of NIR instruments, thus allowing a wide application range, which could provide a supporting technology for the practical application of NIR spectroscopy. MDPI 2023-01-03 /pmc/articles/PMC9823907/ /pubmed/36615595 http://dx.doi.org/10.3390/molecules28010406 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Hui
Tan, Haining
Lin, Boran
Yang, Xiangchun
Sun, Zhongyu
Zhong, Liang
Gao, Lele
Li, Lian
Dong, Qin
Nie, Lei
Zang, Hengchang
Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
title Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
title_full Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
title_fullStr Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
title_full_unstemmed Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
title_short Improved Principal Component Analysis (IPCA): A Novel Method for Quantitative Calibration Transfer between Different Near-Infrared Spectrometers
title_sort improved principal component analysis (ipca): a novel method for quantitative calibration transfer between different near-infrared spectrometers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9823907/
https://www.ncbi.nlm.nih.gov/pubmed/36615595
http://dx.doi.org/10.3390/molecules28010406
work_keys_str_mv AT zhanghui improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT tanhaining improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT linboran improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT yangxiangchun improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT sunzhongyu improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT zhongliang improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT gaolele improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT lilian improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT dongqin improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT nielei improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers
AT zanghengchang improvedprincipalcomponentanalysisipcaanovelmethodforquantitativecalibrationtransferbetweendifferentnearinfraredspectrometers