Cargando…

Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater

This study presents the analogical assessment of the train-induced vibration and radiated noise in a proposed theater. The theater is to be constructed in a region with crowded metro lines, and the assessment is implemented in an analogical building with comparable structural type and metro conditio...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Xiangming, Xiao, Yuchun, Jiang, Huihuang, Guo, Yunlong, Yu, Mengwen, Tan, Wanzhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824341/
https://www.ncbi.nlm.nih.gov/pubmed/36617103
http://dx.doi.org/10.3390/s23010505
_version_ 1784866385974788096
author Liu, Xiangming
Xiao, Yuchun
Jiang, Huihuang
Guo, Yunlong
Yu, Mengwen
Tan, Wanzhong
author_facet Liu, Xiangming
Xiao, Yuchun
Jiang, Huihuang
Guo, Yunlong
Yu, Mengwen
Tan, Wanzhong
author_sort Liu, Xiangming
collection PubMed
description This study presents the analogical assessment of the train-induced vibration and radiated noise in a proposed theater. The theater is to be constructed in a region with crowded metro lines, and the assessment is implemented in an analogical building with comparable structural type and metro condition. Prior to the assessment, the comparability of the analogical building with the theater is validated using the train-induced ground vibration. With the same horizontal distance from the metro line, the train-induced vibration level in the analogical building is 9 dB higher than that in the construction site of the theater. Such results indicate that the lack of soil layers may lead to a dramatic increase in train-induced vibration in the building. In the staircase of the analogical building, the train-induced radiated noise reached 55 dB (A), which is 10 dB (A) higher than the daytime allowable level. As the most important indicator, the noise rating number in the cinema of the analogical building is NR-43, which put forward an enormous challenge on the construction of the theater with a denoise demand of 23 dB. The analogical method applied in this study provides an effective and practical way for the assessment of train-induced vibration and radiated noise in proposed vibration-sensitive buildings. The assessment results that provide necessary reference and support for the anti-vibration design will help guarantee the stage effect of the theater.
format Online
Article
Text
id pubmed-9824341
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98243412023-01-08 Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater Liu, Xiangming Xiao, Yuchun Jiang, Huihuang Guo, Yunlong Yu, Mengwen Tan, Wanzhong Sensors (Basel) Article This study presents the analogical assessment of the train-induced vibration and radiated noise in a proposed theater. The theater is to be constructed in a region with crowded metro lines, and the assessment is implemented in an analogical building with comparable structural type and metro condition. Prior to the assessment, the comparability of the analogical building with the theater is validated using the train-induced ground vibration. With the same horizontal distance from the metro line, the train-induced vibration level in the analogical building is 9 dB higher than that in the construction site of the theater. Such results indicate that the lack of soil layers may lead to a dramatic increase in train-induced vibration in the building. In the staircase of the analogical building, the train-induced radiated noise reached 55 dB (A), which is 10 dB (A) higher than the daytime allowable level. As the most important indicator, the noise rating number in the cinema of the analogical building is NR-43, which put forward an enormous challenge on the construction of the theater with a denoise demand of 23 dB. The analogical method applied in this study provides an effective and practical way for the assessment of train-induced vibration and radiated noise in proposed vibration-sensitive buildings. The assessment results that provide necessary reference and support for the anti-vibration design will help guarantee the stage effect of the theater. MDPI 2023-01-02 /pmc/articles/PMC9824341/ /pubmed/36617103 http://dx.doi.org/10.3390/s23010505 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Xiangming
Xiao, Yuchun
Jiang, Huihuang
Guo, Yunlong
Yu, Mengwen
Tan, Wanzhong
Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater
title Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater
title_full Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater
title_fullStr Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater
title_full_unstemmed Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater
title_short Analogical Assessment of Train-Induced Vibration and Radiated Noise in a Proposed Theater
title_sort analogical assessment of train-induced vibration and radiated noise in a proposed theater
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824341/
https://www.ncbi.nlm.nih.gov/pubmed/36617103
http://dx.doi.org/10.3390/s23010505
work_keys_str_mv AT liuxiangming analogicalassessmentoftraininducedvibrationandradiatednoiseinaproposedtheater
AT xiaoyuchun analogicalassessmentoftraininducedvibrationandradiatednoiseinaproposedtheater
AT jianghuihuang analogicalassessmentoftraininducedvibrationandradiatednoiseinaproposedtheater
AT guoyunlong analogicalassessmentoftraininducedvibrationandradiatednoiseinaproposedtheater
AT yumengwen analogicalassessmentoftraininducedvibrationandradiatednoiseinaproposedtheater
AT tanwanzhong analogicalassessmentoftraininducedvibrationandradiatednoiseinaproposedtheater