Cargando…

PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables

Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three diffe...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaziz, Sinda, Romano, Pietro, Imburgia, Antonino, Ala, Guido, Sghaier, Halim, Flandre, Denis, Tounsi, Fares
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824703/
https://www.ncbi.nlm.nih.gov/pubmed/36616889
http://dx.doi.org/10.3390/s23010290
_version_ 1784866475321851904
author Kaziz, Sinda
Romano, Pietro
Imburgia, Antonino
Ala, Guido
Sghaier, Halim
Flandre, Denis
Tounsi, Fares
author_facet Kaziz, Sinda
Romano, Pietro
Imburgia, Antonino
Ala, Guido
Sghaier, Halim
Flandre, Denis
Tounsi, Fares
author_sort Kaziz, Sinda
collection PubMed
description Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors’ outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made.
format Online
Article
Text
id pubmed-9824703
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98247032023-01-08 PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables Kaziz, Sinda Romano, Pietro Imburgia, Antonino Ala, Guido Sghaier, Halim Flandre, Denis Tounsi, Fares Sensors (Basel) Article Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors’ outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made. MDPI 2022-12-27 /pmc/articles/PMC9824703/ /pubmed/36616889 http://dx.doi.org/10.3390/s23010290 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kaziz, Sinda
Romano, Pietro
Imburgia, Antonino
Ala, Guido
Sghaier, Halim
Flandre, Denis
Tounsi, Fares
PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
title PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
title_full PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
title_fullStr PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
title_full_unstemmed PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
title_short PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
title_sort pcb-based planar inductive loops for partial discharges detection in power cables
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824703/
https://www.ncbi.nlm.nih.gov/pubmed/36616889
http://dx.doi.org/10.3390/s23010290
work_keys_str_mv AT kazizsinda pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables
AT romanopietro pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables
AT imburgiaantonino pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables
AT alaguido pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables
AT sghaierhalim pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables
AT flandredenis pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables
AT tounsifares pcbbasedplanarinductiveloopsforpartialdischargesdetectioninpowercables