Cargando…
Monitoring Single-Phase LV Charging of Electric Vehicles
The paper presents the results of the monitoring process of the charging of an electric vehicle battery pack. Battery pack charging with a capacity of 58 [Formula: see text] was monitored in a single-phase 230 [Formula: see text] /50 [Formula: see text] circuit. The slow charging system used was con...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824892/ https://www.ncbi.nlm.nih.gov/pubmed/36616738 http://dx.doi.org/10.3390/s23010141 |
_version_ | 1784866521693028352 |
---|---|
author | Kuwałek, Piotr Wiczyński, Grzegorz |
author_facet | Kuwałek, Piotr Wiczyński, Grzegorz |
author_sort | Kuwałek, Piotr |
collection | PubMed |
description | The paper presents the results of the monitoring process of the charging of an electric vehicle battery pack. Battery pack charging with a capacity of 58 [Formula: see text] was monitored in a single-phase 230 [Formula: see text] /50 [Formula: see text] circuit. The slow charging system used was configured to obtain a current of 10 [Formula: see text]. During monitoring, the focus was on the recognition of the charging, considering the impact of this process on power quality and, consequently, on the reliability of electrical machines. Research results show that the monitored charges are one-, two-, or three-stage processes. The variations in the currents, power, and higher harmonic contents were observed. The effects of such variations depend on the properties of the power grid at the point of connection of the charging system. Knowledge of the variation of the voltages, currents, and active and reactive power allows for the determination of the requirements of the measuring equipment used for charging the monitoring, including the selection of discrimination/averaging time of monitored quantities. The research results also indicate the need for continuous monitoring of the power quality in the power supply circuit of electrical loads, e.g., electrical machines. Continuous monitoring supports the diagnostics of electrical machines and allows the appropriate measures to increase their reliability. |
format | Online Article Text |
id | pubmed-9824892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98248922023-01-08 Monitoring Single-Phase LV Charging of Electric Vehicles Kuwałek, Piotr Wiczyński, Grzegorz Sensors (Basel) Article The paper presents the results of the monitoring process of the charging of an electric vehicle battery pack. Battery pack charging with a capacity of 58 [Formula: see text] was monitored in a single-phase 230 [Formula: see text] /50 [Formula: see text] circuit. The slow charging system used was configured to obtain a current of 10 [Formula: see text]. During monitoring, the focus was on the recognition of the charging, considering the impact of this process on power quality and, consequently, on the reliability of electrical machines. Research results show that the monitored charges are one-, two-, or three-stage processes. The variations in the currents, power, and higher harmonic contents were observed. The effects of such variations depend on the properties of the power grid at the point of connection of the charging system. Knowledge of the variation of the voltages, currents, and active and reactive power allows for the determination of the requirements of the measuring equipment used for charging the monitoring, including the selection of discrimination/averaging time of monitored quantities. The research results also indicate the need for continuous monitoring of the power quality in the power supply circuit of electrical loads, e.g., electrical machines. Continuous monitoring supports the diagnostics of electrical machines and allows the appropriate measures to increase their reliability. MDPI 2022-12-23 /pmc/articles/PMC9824892/ /pubmed/36616738 http://dx.doi.org/10.3390/s23010141 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kuwałek, Piotr Wiczyński, Grzegorz Monitoring Single-Phase LV Charging of Electric Vehicles |
title | Monitoring Single-Phase LV Charging of Electric Vehicles |
title_full | Monitoring Single-Phase LV Charging of Electric Vehicles |
title_fullStr | Monitoring Single-Phase LV Charging of Electric Vehicles |
title_full_unstemmed | Monitoring Single-Phase LV Charging of Electric Vehicles |
title_short | Monitoring Single-Phase LV Charging of Electric Vehicles |
title_sort | monitoring single-phase lv charging of electric vehicles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824892/ https://www.ncbi.nlm.nih.gov/pubmed/36616738 http://dx.doi.org/10.3390/s23010141 |
work_keys_str_mv | AT kuwałekpiotr monitoringsinglephaselvchargingofelectricvehicles AT wiczynskigrzegorz monitoringsinglephaselvchargingofelectricvehicles |