Cargando…

A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women

OBJECTIVES: The aim of this study was to compare the data of conductance and capacitance measurements of facial skin hydration and to evaluate and discuss the advantages and disadvantages of the different approaches. METHODS: We measured skin capacitance (Corneometer® CM 825) and skin conductance (S...

Descripción completa

Detalles Bibliográficos
Autores principales: Voegeli, Rainer, Cherel, Marie, Schoop, Rotraut, Rawlings, Anthony V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826081/
https://www.ncbi.nlm.nih.gov/pubmed/35980652
http://dx.doi.org/10.1111/ics.12814
_version_ 1784866767598780416
author Voegeli, Rainer
Cherel, Marie
Schoop, Rotraut
Rawlings, Anthony V.
author_facet Voegeli, Rainer
Cherel, Marie
Schoop, Rotraut
Rawlings, Anthony V.
author_sort Voegeli, Rainer
collection PubMed
description OBJECTIVES: The aim of this study was to compare the data of conductance and capacitance measurements of facial skin hydration and to evaluate and discuss the advantages and disadvantages of the different approaches. METHODS: We measured skin capacitance (Corneometer® CM 825) and skin conductance (Skicon‐200EX®) on 30 pre‐defined facial sites of 125 Chinese women, resulting in 3750 readings per device. The data were analysed and compared, and continuous colour maps were generated on a 3D avatar for capacitance, conductance, relative difference (Δ%) and correlation (R‐value) by interpolating between the individual readings and converting the values to colours. This visualization allows a better interpretation of the results. RESULTS: The complexity of facial skin hydration is revealed by this approach. The similarities and discrepancies in the facial hydration maps are clearly apparent. Due to the superiority of the Skicon in measuring high hydration levels, differences in skin hydration were evident on the forehead compared with the Corneometer maps, which may be related to the more superficial measurement of the Skicon within the stratum corneum. Conversely, a greater understanding of the complexity of facial skin hydration in the nasolabial fold was obvious when using the Corneometer. The best congruence between the instruments was found at two specific but separated facial areas, one around the inner eye region and the other one on a line between the nasolabial sulcus and the oblique, lateral jaw. Interestingly, the data were not normally distributed for both instruments and they had opposite skews. All facial clusters were statistically different from each other (p < 0.001), except the cheek and jaw for the Skicon. Larger than expected percentage coefficients of variance were found for the Corneometer on some facial sites that might be explainable by differences in stratum corneum physiology and biochemistry. Corneometer values of 48 AU and Skicon values of 132 μS were taken as the cutoff for normally hydrated facial skin. CONCLUSIONS: Both devices have their advantages and disadvantages suggesting that bio‐instrumental measurement of skin hydration is actually more complicated than commonly thought and that the different facial zones and the use of multiple instrumentation have not been adequately considered.
format Online
Article
Text
id pubmed-9826081
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-98260812023-01-09 A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women Voegeli, Rainer Cherel, Marie Schoop, Rotraut Rawlings, Anthony V. Int J Cosmet Sci Original Articles OBJECTIVES: The aim of this study was to compare the data of conductance and capacitance measurements of facial skin hydration and to evaluate and discuss the advantages and disadvantages of the different approaches. METHODS: We measured skin capacitance (Corneometer® CM 825) and skin conductance (Skicon‐200EX®) on 30 pre‐defined facial sites of 125 Chinese women, resulting in 3750 readings per device. The data were analysed and compared, and continuous colour maps were generated on a 3D avatar for capacitance, conductance, relative difference (Δ%) and correlation (R‐value) by interpolating between the individual readings and converting the values to colours. This visualization allows a better interpretation of the results. RESULTS: The complexity of facial skin hydration is revealed by this approach. The similarities and discrepancies in the facial hydration maps are clearly apparent. Due to the superiority of the Skicon in measuring high hydration levels, differences in skin hydration were evident on the forehead compared with the Corneometer maps, which may be related to the more superficial measurement of the Skicon within the stratum corneum. Conversely, a greater understanding of the complexity of facial skin hydration in the nasolabial fold was obvious when using the Corneometer. The best congruence between the instruments was found at two specific but separated facial areas, one around the inner eye region and the other one on a line between the nasolabial sulcus and the oblique, lateral jaw. Interestingly, the data were not normally distributed for both instruments and they had opposite skews. All facial clusters were statistically different from each other (p < 0.001), except the cheek and jaw for the Skicon. Larger than expected percentage coefficients of variance were found for the Corneometer on some facial sites that might be explainable by differences in stratum corneum physiology and biochemistry. Corneometer values of 48 AU and Skicon values of 132 μS were taken as the cutoff for normally hydrated facial skin. CONCLUSIONS: Both devices have their advantages and disadvantages suggesting that bio‐instrumental measurement of skin hydration is actually more complicated than commonly thought and that the different facial zones and the use of multiple instrumentation have not been adequately considered. John Wiley and Sons Inc. 2022-09-21 2022-12 /pmc/articles/PMC9826081/ /pubmed/35980652 http://dx.doi.org/10.1111/ics.12814 Text en © 2022 DSM Nutritional Products AG. International Journal of Cosmetic Science published by John Wiley & Sons Ltd on behalf of Society of Cosmetic Scientists and Societe Francaise de Cosmetologie. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Voegeli, Rainer
Cherel, Marie
Schoop, Rotraut
Rawlings, Anthony V.
A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women
title A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women
title_full A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women
title_fullStr A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women
title_full_unstemmed A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women
title_short A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women
title_sort comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in chinese women
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826081/
https://www.ncbi.nlm.nih.gov/pubmed/35980652
http://dx.doi.org/10.1111/ics.12814
work_keys_str_mv AT voegelirainer acomprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT cherelmarie acomprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT schooprotraut acomprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT rawlingsanthonyv acomprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT voegelirainer comprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT cherelmarie comprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT schooprotraut comprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen
AT rawlingsanthonyv comprehensivecomparisonoffacialskinhydrationbasedoncapacitanceandconductancemeasurementsinchinesewomen