Intraoperative pump thrombosis (PT) in HeartMate (HM) III

Pump thrombosis (PT) is a rare and infrequent complication of HeartMate III left ventricular assist device (LVAD). While there are reports of PT in the postoperative period, to our knowledge, there have been no prior reports on PT in the intraoperative period. Here we present a case of a 24‐year‐old...

Descripción completa

Detalles Bibliográficos
Autores principales: Karuppiah, Sathappan, Setty, Sudharsan, John, Ranjit, Lupei, Monica
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826477/
https://www.ncbi.nlm.nih.gov/pubmed/36116047
http://dx.doi.org/10.1111/jocs.16941
Descripción
Sumario:Pump thrombosis (PT) is a rare and infrequent complication of HeartMate III left ventricular assist device (LVAD). While there are reports of PT in the postoperative period, to our knowledge, there have been no prior reports on PT in the intraoperative period. Here we present a case of a 24‐year‐old female who required HeartMate III LVAD implantation for progressive heart failure and the intraoperative period was complicated with PT. Managing PT in the intraoperative period is challenging and time‐sensitive because of its rare occurrence and paucity of recommendations in diagnosing the PT.