Cargando…
Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction
PURPOSE: Free-breathing Magnetization Transfer Contrast Bright blOOd phase SensiTive (MTC-BOOST) is a prototype balanced-Steady-State Free Precession sequence for 3D whole-heart imaging, that employs the endogenous magnetisation transfer contrast mechanism. This achieves reduction of flow and off-re...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826869/ https://www.ncbi.nlm.nih.gov/pubmed/35772584 http://dx.doi.org/10.1016/j.mri.2022.06.012 |
_version_ | 1784866950495600640 |
---|---|
author | Fotaki, Anastasia Fuin, Niccolo Nordio, Giovanna Velasco Jimeno, Carlos Qi, Haikun Emmanuel, Yaso Pushparajah, Kuberan Botnar, René M. Prieto, Claudia |
author_facet | Fotaki, Anastasia Fuin, Niccolo Nordio, Giovanna Velasco Jimeno, Carlos Qi, Haikun Emmanuel, Yaso Pushparajah, Kuberan Botnar, René M. Prieto, Claudia |
author_sort | Fotaki, Anastasia |
collection | PubMed |
description | PURPOSE: Free-breathing Magnetization Transfer Contrast Bright blOOd phase SensiTive (MTC-BOOST) is a prototype balanced-Steady-State Free Precession sequence for 3D whole-heart imaging, that employs the endogenous magnetisation transfer contrast mechanism. This achieves reduction of flow and off-resonance artefacts, that often arise with the clinical T2prepared balanced-Steady-State Free Precession sequence, enabling high quality, contrast-agent free imaging of the thoracic cardiovascular anatomy. Fully-sampled MTC-BOOST acquisition requires long scan times (~10–24 min) and therefore acceleration is needed to permit its clinical incorporation. The aim of this study is to enable and clinically validate the 5-fold accelerated MTC-BOOST acquisition with joint Multi-Scale Variational Neural Network (jMS-VNN) reconstruction. METHODS: Thirty-six patients underwent free-breathing, 3D whole-heart imaging with the MTC-BOOST sequence, which is combined with variable density spiral-like Cartesian sampling and 2D image navigators for translational motion estimation. This sequence acquires two differently weighted bright-blood volumes in an interleaved fashion, which are then joined in a phase sensitive inversion recovery reconstruction to obtain a complementary fully co-registered black-blood volume. Data from eighteen patients were used for training, whereas data from the remaining eighteen patients were used for testing/evaluation. The proposed deep-learning based approach adopts a supervised multi-scale variational neural network for joint reconstruction of the two differently weighted bright-blood volumes acquired with the 5-fold accelerated MTC-BOOST. The two contrast images are stacked as different channels in the network to exploit the shared information. The proposed approach is compared to the fully-sampled MTC-BOOST and 5-fold undersampled MTC-BOOST acquisition with Compressed Sensing (CS) reconstruction in terms of scan/reconstruction time and bright-blood image quality. Comparison against conventional 2-fold undersampled T2-prepared 3D bright-blood whole-heart clinical sequence (T2prep-3DWH) is also included. RESULTS: Acquisition time was 3.0 ± 1.0 min for the 5-fold accelerated MTC-BOOST versus 9.0 ± 1.1 min for the fully-sampled MTC-BOOST and 11.1 ± 2.6 min for the T2prep-3DWH (p < 0.001 and p < 0.001, respectively). Reconstruction time was significantly lower with the jMS-VNN method compared to CS (10 ± 0.5 min vs 20 ± 2 s, p < 0.001). Image quality was higher for the proposed 5-fold undersampled jMS-VNN versus conventional CS, comparable or higher to the corresponding T2prep-3DWH dataset and similar to the fully-sampled MTC-BOOST. CONCLUSION: The proposed 5-fold accelerated jMS-VNN MTC-BOOST framework provides efficient 3D whole-heart bright-blood imaging in fast acquisition and reconstruction time with concomitant reduction of flow and off-resonance artefacts, that are frequently encountered with the clinical sequence. Image quality of the cardiac anatomy and thoracic vasculature is comparable or superior to the clinical scan and 5-fold CS reconstruction in faster reconstruction time, promising potential clinical adoption. |
format | Online Article Text |
id | pubmed-9826869 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-98268692023-01-10 Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction Fotaki, Anastasia Fuin, Niccolo Nordio, Giovanna Velasco Jimeno, Carlos Qi, Haikun Emmanuel, Yaso Pushparajah, Kuberan Botnar, René M. Prieto, Claudia Magn Reson Imaging Original Contribution PURPOSE: Free-breathing Magnetization Transfer Contrast Bright blOOd phase SensiTive (MTC-BOOST) is a prototype balanced-Steady-State Free Precession sequence for 3D whole-heart imaging, that employs the endogenous magnetisation transfer contrast mechanism. This achieves reduction of flow and off-resonance artefacts, that often arise with the clinical T2prepared balanced-Steady-State Free Precession sequence, enabling high quality, contrast-agent free imaging of the thoracic cardiovascular anatomy. Fully-sampled MTC-BOOST acquisition requires long scan times (~10–24 min) and therefore acceleration is needed to permit its clinical incorporation. The aim of this study is to enable and clinically validate the 5-fold accelerated MTC-BOOST acquisition with joint Multi-Scale Variational Neural Network (jMS-VNN) reconstruction. METHODS: Thirty-six patients underwent free-breathing, 3D whole-heart imaging with the MTC-BOOST sequence, which is combined with variable density spiral-like Cartesian sampling and 2D image navigators for translational motion estimation. This sequence acquires two differently weighted bright-blood volumes in an interleaved fashion, which are then joined in a phase sensitive inversion recovery reconstruction to obtain a complementary fully co-registered black-blood volume. Data from eighteen patients were used for training, whereas data from the remaining eighteen patients were used for testing/evaluation. The proposed deep-learning based approach adopts a supervised multi-scale variational neural network for joint reconstruction of the two differently weighted bright-blood volumes acquired with the 5-fold accelerated MTC-BOOST. The two contrast images are stacked as different channels in the network to exploit the shared information. The proposed approach is compared to the fully-sampled MTC-BOOST and 5-fold undersampled MTC-BOOST acquisition with Compressed Sensing (CS) reconstruction in terms of scan/reconstruction time and bright-blood image quality. Comparison against conventional 2-fold undersampled T2-prepared 3D bright-blood whole-heart clinical sequence (T2prep-3DWH) is also included. RESULTS: Acquisition time was 3.0 ± 1.0 min for the 5-fold accelerated MTC-BOOST versus 9.0 ± 1.1 min for the fully-sampled MTC-BOOST and 11.1 ± 2.6 min for the T2prep-3DWH (p < 0.001 and p < 0.001, respectively). Reconstruction time was significantly lower with the jMS-VNN method compared to CS (10 ± 0.5 min vs 20 ± 2 s, p < 0.001). Image quality was higher for the proposed 5-fold undersampled jMS-VNN versus conventional CS, comparable or higher to the corresponding T2prep-3DWH dataset and similar to the fully-sampled MTC-BOOST. CONCLUSION: The proposed 5-fold accelerated jMS-VNN MTC-BOOST framework provides efficient 3D whole-heart bright-blood imaging in fast acquisition and reconstruction time with concomitant reduction of flow and off-resonance artefacts, that are frequently encountered with the clinical sequence. Image quality of the cardiac anatomy and thoracic vasculature is comparable or superior to the clinical scan and 5-fold CS reconstruction in faster reconstruction time, promising potential clinical adoption. Elsevier 2022-10 /pmc/articles/PMC9826869/ /pubmed/35772584 http://dx.doi.org/10.1016/j.mri.2022.06.012 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Contribution Fotaki, Anastasia Fuin, Niccolo Nordio, Giovanna Velasco Jimeno, Carlos Qi, Haikun Emmanuel, Yaso Pushparajah, Kuberan Botnar, René M. Prieto, Claudia Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
title | Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
title_full | Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
title_fullStr | Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
title_full_unstemmed | Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
title_short | Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
title_sort | accelerating 3d mtc-boost in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction |
topic | Original Contribution |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826869/ https://www.ncbi.nlm.nih.gov/pubmed/35772584 http://dx.doi.org/10.1016/j.mri.2022.06.012 |
work_keys_str_mv | AT fotakianastasia accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT fuinniccolo accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT nordiogiovanna accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT velascojimenocarlos accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT qihaikun accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT emmanuelyaso accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT pushparajahkuberan accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT botnarrenem accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction AT prietoclaudia accelerating3dmtcboostinpatientswithcongenitalheartdiseaseusingajointmultiscalevariationalneuralnetworkreconstruction |