Cargando…
Investigating the intra-session reliability of short and long latency afferent inhibition
OBJECTIVE: To establish the intrasession relative and absolute reliability of Short (SAI) and Long-Latency Afferent Inhibition (LAI). These findings will allow us to guide future explorations of changes to these measures. METHODS: 31 healthy individuals (21.06 ± 2.85 years) had SAI and LAI obtained...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826929/ https://www.ncbi.nlm.nih.gov/pubmed/36632369 http://dx.doi.org/10.1016/j.cnp.2022.12.001 |
_version_ | 1784866965922250752 |
---|---|
author | Rehsi, Ravjot S. Ramdeo, Karishma R. Foglia, Stevie D. Turco, Claudia V. Adams, Faith C. Toepp, Stephen L. Nelson, Aimee J. |
author_facet | Rehsi, Ravjot S. Ramdeo, Karishma R. Foglia, Stevie D. Turco, Claudia V. Adams, Faith C. Toepp, Stephen L. Nelson, Aimee J. |
author_sort | Rehsi, Ravjot S. |
collection | PubMed |
description | OBJECTIVE: To establish the intrasession relative and absolute reliability of Short (SAI) and Long-Latency Afferent Inhibition (LAI). These findings will allow us to guide future explorations of changes to these measures. METHODS: 31 healthy individuals (21.06 ± 2.85 years) had SAI and LAI obtained thrice at 30-minute intervals in one session. To identify the minimum number of trials required to reliably elicit SAI and LAI, relative reliability was assessed at running intervals of 5 trials. RESULTS: SAI had moderate–high, and LAI had high-excellent relative reliability. Both SAI and LAI had high amounts of measurement error. LAI had high relative reliability when only 5 frames of data were included, whereas SAI required ∼20–30 frames of data for the same. For both SAI and LAI, individual smallest detectable change was large but was reduced at the group level. CONCLUSIONS: SAI and LAI can be used for both diagnostic purposes and to assess group level change but have limited utility in assessing within-individual changes. SIGNIFICANCE: These results can be used to inform future work regarding the utility of SAI and LAI, particularly in terms of their ability to identify particularly high or low values of afferent inhibition. |
format | Online Article Text |
id | pubmed-9826929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-98269292023-01-10 Investigating the intra-session reliability of short and long latency afferent inhibition Rehsi, Ravjot S. Ramdeo, Karishma R. Foglia, Stevie D. Turco, Claudia V. Adams, Faith C. Toepp, Stephen L. Nelson, Aimee J. Clin Neurophysiol Pract Research Paper OBJECTIVE: To establish the intrasession relative and absolute reliability of Short (SAI) and Long-Latency Afferent Inhibition (LAI). These findings will allow us to guide future explorations of changes to these measures. METHODS: 31 healthy individuals (21.06 ± 2.85 years) had SAI and LAI obtained thrice at 30-minute intervals in one session. To identify the minimum number of trials required to reliably elicit SAI and LAI, relative reliability was assessed at running intervals of 5 trials. RESULTS: SAI had moderate–high, and LAI had high-excellent relative reliability. Both SAI and LAI had high amounts of measurement error. LAI had high relative reliability when only 5 frames of data were included, whereas SAI required ∼20–30 frames of data for the same. For both SAI and LAI, individual smallest detectable change was large but was reduced at the group level. CONCLUSIONS: SAI and LAI can be used for both diagnostic purposes and to assess group level change but have limited utility in assessing within-individual changes. SIGNIFICANCE: These results can be used to inform future work regarding the utility of SAI and LAI, particularly in terms of their ability to identify particularly high or low values of afferent inhibition. Elsevier 2022-12-21 /pmc/articles/PMC9826929/ /pubmed/36632369 http://dx.doi.org/10.1016/j.cnp.2022.12.001 Text en © 2022 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Paper Rehsi, Ravjot S. Ramdeo, Karishma R. Foglia, Stevie D. Turco, Claudia V. Adams, Faith C. Toepp, Stephen L. Nelson, Aimee J. Investigating the intra-session reliability of short and long latency afferent inhibition |
title | Investigating the intra-session reliability of short and long latency afferent inhibition |
title_full | Investigating the intra-session reliability of short and long latency afferent inhibition |
title_fullStr | Investigating the intra-session reliability of short and long latency afferent inhibition |
title_full_unstemmed | Investigating the intra-session reliability of short and long latency afferent inhibition |
title_short | Investigating the intra-session reliability of short and long latency afferent inhibition |
title_sort | investigating the intra-session reliability of short and long latency afferent inhibition |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9826929/ https://www.ncbi.nlm.nih.gov/pubmed/36632369 http://dx.doi.org/10.1016/j.cnp.2022.12.001 |
work_keys_str_mv | AT rehsiravjots investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition AT ramdeokarishmar investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition AT fogliastevied investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition AT turcoclaudiav investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition AT adamsfaithc investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition AT toeppstephenl investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition AT nelsonaimeej investigatingtheintrasessionreliabilityofshortandlonglatencyafferentinhibition |