Cargando…
Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index
BACKGROUND: The popularity of noninvasive body contouring procedures has been steadily increasing in recent years, however, studies evaluating its effectiveness in individuals with overweight range body mass index (BMI) are limited. OBJECTIVE: To evaluate the efficacy and safety of combined 2 MHz ra...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9828667/ https://www.ncbi.nlm.nih.gov/pubmed/36183371 http://dx.doi.org/10.1002/lsm.23606 |
_version_ | 1784867318020440064 |
---|---|
author | Manuskiatti, Woraphong Nanchaipruek, Yanisorn Gervasio, Mia Katrina Lektrakul, Nittaya Apinuntham, Chalermkwan |
author_facet | Manuskiatti, Woraphong Nanchaipruek, Yanisorn Gervasio, Mia Katrina Lektrakul, Nittaya Apinuntham, Chalermkwan |
author_sort | Manuskiatti, Woraphong |
collection | PubMed |
description | BACKGROUND: The popularity of noninvasive body contouring procedures has been steadily increasing in recent years, however, studies evaluating its effectiveness in individuals with overweight range body mass index (BMI) are limited. OBJECTIVE: To evaluate the efficacy and safety of combined 2 MHz radiofrequency (RF) and electrical multidirectional stimulation (EMDS) for the improvement of the abdominal contour in subjects with overweight range BMI. METHODS: Twelve participants with overweight range BMI (23.6–24.9 kg/m(2)) underwent a single RF treatment, followed by a series of six EMDS treatments. Follow‐up assessments (abdominal circumference [AC] and skinfold thickness measurements) were scheduled 1, 2, and 3 months after the final session. RESULTS: At 1 month after the final treatment, a 3.1% (2.6 ± 0.47 cm, mean ± SD) significant reduction in mean AC was observed (p ˂ 0.001) and a maximal skinfold thickness reduction of 14% (4.6 ± 1.1 mm) was also noted (p = 0.032). Transient dysesthesia lasting 2–3 hours after EMDS treatment was the most common adverse effect reported by 5 of 12 subjects (41.7%), with no other serious side effects. CONCLUSIONS: Combined RF and EMDS treatments are safe and effective, yielding significant reductions in both AC and skinfold thickness in patients with overweight range BMI, causing only minimal and transient adverse effects. |
format | Online Article Text |
id | pubmed-9828667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98286672023-01-10 Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index Manuskiatti, Woraphong Nanchaipruek, Yanisorn Gervasio, Mia Katrina Lektrakul, Nittaya Apinuntham, Chalermkwan Lasers Surg Med Clinical Reports BACKGROUND: The popularity of noninvasive body contouring procedures has been steadily increasing in recent years, however, studies evaluating its effectiveness in individuals with overweight range body mass index (BMI) are limited. OBJECTIVE: To evaluate the efficacy and safety of combined 2 MHz radiofrequency (RF) and electrical multidirectional stimulation (EMDS) for the improvement of the abdominal contour in subjects with overweight range BMI. METHODS: Twelve participants with overweight range BMI (23.6–24.9 kg/m(2)) underwent a single RF treatment, followed by a series of six EMDS treatments. Follow‐up assessments (abdominal circumference [AC] and skinfold thickness measurements) were scheduled 1, 2, and 3 months after the final session. RESULTS: At 1 month after the final treatment, a 3.1% (2.6 ± 0.47 cm, mean ± SD) significant reduction in mean AC was observed (p ˂ 0.001) and a maximal skinfold thickness reduction of 14% (4.6 ± 1.1 mm) was also noted (p = 0.032). Transient dysesthesia lasting 2–3 hours after EMDS treatment was the most common adverse effect reported by 5 of 12 subjects (41.7%), with no other serious side effects. CONCLUSIONS: Combined RF and EMDS treatments are safe and effective, yielding significant reductions in both AC and skinfold thickness in patients with overweight range BMI, causing only minimal and transient adverse effects. John Wiley and Sons Inc. 2022-10-02 2022-11 /pmc/articles/PMC9828667/ /pubmed/36183371 http://dx.doi.org/10.1002/lsm.23606 Text en © 2022 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Clinical Reports Manuskiatti, Woraphong Nanchaipruek, Yanisorn Gervasio, Mia Katrina Lektrakul, Nittaya Apinuntham, Chalermkwan Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
title | Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
title_full | Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
title_fullStr | Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
title_full_unstemmed | Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
title_short | Combination of monopolar 2 MHz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
title_sort | combination of monopolar 2 mhz radiofrequency and electrical multidirectional stimulation for reducing abdominal circumference and enhancing the muscle definition in subjects with overweight range body mass index |
topic | Clinical Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9828667/ https://www.ncbi.nlm.nih.gov/pubmed/36183371 http://dx.doi.org/10.1002/lsm.23606 |
work_keys_str_mv | AT manuskiattiworaphong combinationofmonopolar2mhzradiofrequencyandelectricalmultidirectionalstimulationforreducingabdominalcircumferenceandenhancingthemuscledefinitioninsubjectswithoverweightrangebodymassindex AT nanchaipruekyanisorn combinationofmonopolar2mhzradiofrequencyandelectricalmultidirectionalstimulationforreducingabdominalcircumferenceandenhancingthemuscledefinitioninsubjectswithoverweightrangebodymassindex AT gervasiomiakatrina combinationofmonopolar2mhzradiofrequencyandelectricalmultidirectionalstimulationforreducingabdominalcircumferenceandenhancingthemuscledefinitioninsubjectswithoverweightrangebodymassindex AT lektrakulnittaya combinationofmonopolar2mhzradiofrequencyandelectricalmultidirectionalstimulationforreducingabdominalcircumferenceandenhancingthemuscledefinitioninsubjectswithoverweightrangebodymassindex AT apinunthamchalermkwan combinationofmonopolar2mhzradiofrequencyandelectricalmultidirectionalstimulationforreducingabdominalcircumferenceandenhancingthemuscledefinitioninsubjectswithoverweightrangebodymassindex |