Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density

Background: The entry of the concept of nanotechnologies into the field of biomaterials has improved the results of their use in regenerative therapies based on the principles of tissue engineering, due to its improvement of the physical properties of materials manufactured in this way, so it has be...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahfuri, Ali, Shehada, Asaad, Darwich, Khaldoun, Saima, Ruwaida
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9829013/
https://www.ncbi.nlm.nih.gov/pubmed/36632245
http://dx.doi.org/10.7759/cureus.32381
_version_ 1784867387315585024
author Mahfuri, Ali
Shehada, Asaad
Darwich, Khaldoun
Saima, Ruwaida
author_facet Mahfuri, Ali
Shehada, Asaad
Darwich, Khaldoun
Saima, Ruwaida
author_sort Mahfuri, Ali
collection PubMed
description Background: The entry of the concept of nanotechnologies into the field of biomaterials has improved the results of their use in regenerative therapies based on the principles of tissue engineering, due to its improvement of the physical properties of materials manufactured in this way, so it has become possible to produce particles of hydroxyapatite in nano sizes. Aim of the study: This study will evaluate the efficacy of applying nanohydroxyapatite paste and platelet-rich fibrin (PRF) as a barrier membrane in comparison with traditional hydroxyapatite (a powder consisting of macro-sized particles) and PRF as a barrier membrane in symmetrically extracted alveoli of the mandible. Materials and methods: The research sample consisted of 40 lower alveoli (symmetrical) of the extracted teeth. The study samples were divided randomly into two groups. Group 1: A paste of nanohydroxyapatite with PRF as a barrier membrane was applied to one side of the extraction. Group 2: Hydroxyapatite powder with PRF as a barrier membrane was applied to the alveolus from the opposite side of Group 1 (the opposite side of the extraction). Three radiographs were performed by cone beam conventional tomography (CBCT) in three consecutive periods to conduct the radiological study (T0: immediately after extraction and grafting, T1: after three months, T2: after six months). Results: The mean of the radiographic bone density of the hydroxyapatite powder group at time T0 is 824.36 HU with a standard deviation of ±277.29 HU, and at time T1 is 1119.93 HU with a standard deviation of ±306.93 HU, and at time T2 is 1074.14 HU with a standard deviation of ±223.62 HU, with statistically significant differences when comparing the amount of change in radiographic bone density at time T0 and T1 with P < 0.05, and at time T0 and T2 with P < 0.05, but there were no significant differences when comparing the amount of change in radiographic bone density in T1 and T2 times with P > 0.05. The mean radiographic bone density of the nanohydroxyapatite paste group at time T0 is 629.88 HU with a standard deviation of ±193.64 HU, and at time T1 is 960.67 HU with a standard deviation of ±256.88 HU, and at time T2 is 743.87 HU with a standard deviation of ±180.96 HU, and in the time T0 and T1 with P < 0.05, and in the time T0 and T2 with P < 0.05, and in the time T1 and T2 with P < 0.05. Statistically, significant differences have been found between bone density change T1, T2 in the nanohydroxyapatite paste group and bone density change T1, T2 in the hydroxyapatite powder group P<0.05, which expresses a greater loss of density in the nanohydroxyapatite group, and thus the resorption of the bone graft and the placement of new bone tissue. Conclusion: Within the limits of our study, the results demonstrated that the use of traditional hydroxyapatite powder and nanohydroxyapatite paste increases the radiographic bone density, nanohydroxyapatite paste has a greater absorbency after 3 months compared with traditional hydroxyapatite powder which helps replace it by natural bone tissue.
format Online
Article
Text
id pubmed-9829013
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-98290132023-01-10 Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density Mahfuri, Ali Shehada, Asaad Darwich, Khaldoun Saima, Ruwaida Cureus Dentistry Background: The entry of the concept of nanotechnologies into the field of biomaterials has improved the results of their use in regenerative therapies based on the principles of tissue engineering, due to its improvement of the physical properties of materials manufactured in this way, so it has become possible to produce particles of hydroxyapatite in nano sizes. Aim of the study: This study will evaluate the efficacy of applying nanohydroxyapatite paste and platelet-rich fibrin (PRF) as a barrier membrane in comparison with traditional hydroxyapatite (a powder consisting of macro-sized particles) and PRF as a barrier membrane in symmetrically extracted alveoli of the mandible. Materials and methods: The research sample consisted of 40 lower alveoli (symmetrical) of the extracted teeth. The study samples were divided randomly into two groups. Group 1: A paste of nanohydroxyapatite with PRF as a barrier membrane was applied to one side of the extraction. Group 2: Hydroxyapatite powder with PRF as a barrier membrane was applied to the alveolus from the opposite side of Group 1 (the opposite side of the extraction). Three radiographs were performed by cone beam conventional tomography (CBCT) in three consecutive periods to conduct the radiological study (T0: immediately after extraction and grafting, T1: after three months, T2: after six months). Results: The mean of the radiographic bone density of the hydroxyapatite powder group at time T0 is 824.36 HU with a standard deviation of ±277.29 HU, and at time T1 is 1119.93 HU with a standard deviation of ±306.93 HU, and at time T2 is 1074.14 HU with a standard deviation of ±223.62 HU, with statistically significant differences when comparing the amount of change in radiographic bone density at time T0 and T1 with P < 0.05, and at time T0 and T2 with P < 0.05, but there were no significant differences when comparing the amount of change in radiographic bone density in T1 and T2 times with P > 0.05. The mean radiographic bone density of the nanohydroxyapatite paste group at time T0 is 629.88 HU with a standard deviation of ±193.64 HU, and at time T1 is 960.67 HU with a standard deviation of ±256.88 HU, and at time T2 is 743.87 HU with a standard deviation of ±180.96 HU, and in the time T0 and T1 with P < 0.05, and in the time T0 and T2 with P < 0.05, and in the time T1 and T2 with P < 0.05. Statistically, significant differences have been found between bone density change T1, T2 in the nanohydroxyapatite paste group and bone density change T1, T2 in the hydroxyapatite powder group P<0.05, which expresses a greater loss of density in the nanohydroxyapatite group, and thus the resorption of the bone graft and the placement of new bone tissue. Conclusion: Within the limits of our study, the results demonstrated that the use of traditional hydroxyapatite powder and nanohydroxyapatite paste increases the radiographic bone density, nanohydroxyapatite paste has a greater absorbency after 3 months compared with traditional hydroxyapatite powder which helps replace it by natural bone tissue. Cureus 2022-12-10 /pmc/articles/PMC9829013/ /pubmed/36632245 http://dx.doi.org/10.7759/cureus.32381 Text en Copyright © 2022, Mahfuri et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Mahfuri, Ali
Shehada, Asaad
Darwich, Khaldoun
Saima, Ruwaida
Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density
title Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density
title_full Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density
title_fullStr Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density
title_full_unstemmed Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density
title_short Radiological Comparative Study Between Conventional and Nano Hydroxyapatite With Platelet-Rich Fibrin (PRF) Membranes for Their Effects on Alveolar Bone Density
title_sort radiological comparative study between conventional and nano hydroxyapatite with platelet-rich fibrin (prf) membranes for their effects on alveolar bone density
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9829013/
https://www.ncbi.nlm.nih.gov/pubmed/36632245
http://dx.doi.org/10.7759/cureus.32381
work_keys_str_mv AT mahfuriali radiologicalcomparativestudybetweenconventionalandnanohydroxyapatitewithplateletrichfibrinprfmembranesfortheireffectsonalveolarbonedensity
AT shehadaasaad radiologicalcomparativestudybetweenconventionalandnanohydroxyapatitewithplateletrichfibrinprfmembranesfortheireffectsonalveolarbonedensity
AT darwichkhaldoun radiologicalcomparativestudybetweenconventionalandnanohydroxyapatitewithplateletrichfibrinprfmembranesfortheireffectsonalveolarbonedensity
AT saimaruwaida radiologicalcomparativestudybetweenconventionalandnanohydroxyapatitewithplateletrichfibrinprfmembranesfortheireffectsonalveolarbonedensity