The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review

Introduction: The aim of this study was to review the effect of irreversible electroporation parameter settings on the size of the ablation zone and the occurrence of thermal effects. This insight would help to optimize treatment protocols and effectively ablate a tumor while controlling the occurre...

Descripción completa

Detalles Bibliográficos
Autores principales: Hogenes, Annemiek M, Overduin, Christiaan G, Slump, Cornelis H, van Laarhoven, Cornelis J H M, Fütterer, Jurgen J, ten Broek, Richard P G, Stommel, Martijn W J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830580/
https://www.ncbi.nlm.nih.gov/pubmed/36598035
http://dx.doi.org/10.1177/15330338221125003
_version_ 1784867699172573184
author Hogenes, Annemiek M
Overduin, Christiaan G
Slump, Cornelis H
van Laarhoven, Cornelis J H M
Fütterer, Jurgen J
ten Broek, Richard P G
Stommel, Martijn W J
author_facet Hogenes, Annemiek M
Overduin, Christiaan G
Slump, Cornelis H
van Laarhoven, Cornelis J H M
Fütterer, Jurgen J
ten Broek, Richard P G
Stommel, Martijn W J
author_sort Hogenes, Annemiek M
collection PubMed
description Introduction: The aim of this study was to review the effect of irreversible electroporation parameter settings on the size of the ablation zone and the occurrence of thermal effects. This insight would help to optimize treatment protocols and effectively ablate a tumor while controlling the occurrence of thermal effects. Methods: Various individual studies report the influence of variation in electroporation parameters on the ablation zone size or occurrence of thermal effects. However, no connections have yet been established between these studies. With the aim of closing the gap in the understanding of and personalizing irreversible electroporation parameter settings, a systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A quality assessment was performed using an in-house developed grading tool based on components of commonly used grading domains. Data on the electroporation parameters voltage, number of electrodes, inter-electrode distance, active needle length, pulse length/number/protocol/frequency, and pulse interval were extracted. Ablation zone size and temperature data were grouped per parameter. Spearman correlation and linear regression were used to define the correlation with outcome measures. Results: A total of 7661 articles were screened, of which 18 preclinical studies (animal and phantom studies) met the inclusion criteria. These studies were graded as moderate (4/18) and low (14/18) quality. Only the applied voltage appeared to be a significant linear predictor of ablation zone size: length, surface, and volume. The pulse number was moderately but nonlinearly correlated with the ablation zone length. Thermal effects were more likely to occur for higher voltages (≥2000 V), higher number of electrodes, and increased active needle length. Conclusion: Firm conclusions are limited since studies that investigated and precisely reported the influence of electroporation parameters on the ablation zone size and thermal effects were scarce and mostly graded low quality. High-quality studies are needed to improve the predictability of the combined effect of variation in parameter combinations and optimize irreversible electroporation treatment protocols.
format Online
Article
Text
id pubmed-9830580
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-98305802023-01-11 The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review Hogenes, Annemiek M Overduin, Christiaan G Slump, Cornelis H van Laarhoven, Cornelis J H M Fütterer, Jurgen J ten Broek, Richard P G Stommel, Martijn W J Technol Cancer Res Treat Meta-Analysis Introduction: The aim of this study was to review the effect of irreversible electroporation parameter settings on the size of the ablation zone and the occurrence of thermal effects. This insight would help to optimize treatment protocols and effectively ablate a tumor while controlling the occurrence of thermal effects. Methods: Various individual studies report the influence of variation in electroporation parameters on the ablation zone size or occurrence of thermal effects. However, no connections have yet been established between these studies. With the aim of closing the gap in the understanding of and personalizing irreversible electroporation parameter settings, a systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A quality assessment was performed using an in-house developed grading tool based on components of commonly used grading domains. Data on the electroporation parameters voltage, number of electrodes, inter-electrode distance, active needle length, pulse length/number/protocol/frequency, and pulse interval were extracted. Ablation zone size and temperature data were grouped per parameter. Spearman correlation and linear regression were used to define the correlation with outcome measures. Results: A total of 7661 articles were screened, of which 18 preclinical studies (animal and phantom studies) met the inclusion criteria. These studies were graded as moderate (4/18) and low (14/18) quality. Only the applied voltage appeared to be a significant linear predictor of ablation zone size: length, surface, and volume. The pulse number was moderately but nonlinearly correlated with the ablation zone length. Thermal effects were more likely to occur for higher voltages (≥2000 V), higher number of electrodes, and increased active needle length. Conclusion: Firm conclusions are limited since studies that investigated and precisely reported the influence of electroporation parameters on the ablation zone size and thermal effects were scarce and mostly graded low quality. High-quality studies are needed to improve the predictability of the combined effect of variation in parameter combinations and optimize irreversible electroporation treatment protocols. SAGE Publications 2023-01-04 /pmc/articles/PMC9830580/ /pubmed/36598035 http://dx.doi.org/10.1177/15330338221125003 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Meta-Analysis
Hogenes, Annemiek M
Overduin, Christiaan G
Slump, Cornelis H
van Laarhoven, Cornelis J H M
Fütterer, Jurgen J
ten Broek, Richard P G
Stommel, Martijn W J
The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review
title The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review
title_full The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review
title_fullStr The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review
title_full_unstemmed The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review
title_short The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review
title_sort influence of irreversible electroporation parameters on the size of the ablation zone and thermal effects: a systematic review
topic Meta-Analysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830580/
https://www.ncbi.nlm.nih.gov/pubmed/36598035
http://dx.doi.org/10.1177/15330338221125003
work_keys_str_mv AT hogenesannemiekm theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT overduinchristiaang theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT slumpcornelish theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT vanlaarhovencornelisjhm theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT futtererjurgenj theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT tenbroekrichardpg theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT stommelmartijnwj theinfluenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT hogenesannemiekm influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT overduinchristiaang influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT slumpcornelish influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT vanlaarhovencornelisjhm influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT futtererjurgenj influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT tenbroekrichardpg influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview
AT stommelmartijnwj influenceofirreversibleelectroporationparametersonthesizeoftheablationzoneandthermaleffectsasystematicreview