Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa

BACKGROUND: In medical imaging, a computed tomography (CT) scanner is a major source of ionizing radiation. All medical radiation exposures should be justified and optimized to meet the clinical diagnosis. Thus, to avoid unnecessary radiation doses for patients, diagnostic reference levels (DRLs) ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumsa, Marema Jebessa, Nguse, Teklehaimanot Mezgebe, Ambessa, Haleluya Biredaw, Gele, Tesfaye Tefera, Fantaye, Wondemu Geteye, Dellie, Seife Teferi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830915/
https://www.ncbi.nlm.nih.gov/pubmed/36624411
http://dx.doi.org/10.1186/s12880-023-00963-1
_version_ 1784867764169605120
author Kumsa, Marema Jebessa
Nguse, Teklehaimanot Mezgebe
Ambessa, Haleluya Biredaw
Gele, Tesfaye Tefera
Fantaye, Wondemu Geteye
Dellie, Seife Teferi
author_facet Kumsa, Marema Jebessa
Nguse, Teklehaimanot Mezgebe
Ambessa, Haleluya Biredaw
Gele, Tesfaye Tefera
Fantaye, Wondemu Geteye
Dellie, Seife Teferi
author_sort Kumsa, Marema Jebessa
collection PubMed
description BACKGROUND: In medical imaging, a computed tomography (CT) scanner is a major source of ionizing radiation. All medical radiation exposures should be justified and optimized to meet the clinical diagnosis. Thus, to avoid unnecessary radiation doses for patients, diagnostic reference levels (DRLs) have been used. The DRLs are used to identify unusually high radiation doses during CT procedures, which are not appropriate for the clinical diagnosis. It has been successfully implemented in Europe, Canada, Australia, the United States, several industrialized countries, and a few underdeveloped countries. The present study aimed to establish DRLs for the head, chest, and abdominopelvic (AP) CT procedures in Addis Ababa, Ethiopia. METHODS: A pilot study identified the most frequent CT examinations in the city. At the time of the pilot, eighteen CT scan facilities were identified as having functioning CT scanners. Then, on nine CT facilities (50% of functional CT scanners), a prospective analysis of volume CT dose index (CTDI(vol)) and dose length product (DLP) was performed. We collected data for 838 adult patients’ head, chest, and AP CT examinations. SPSS version 25 was used to compute the median values of the DLP and CTDI(vol) dose indicators. The rounded 75th percentile of CTDI(vol) and DLP median values were used to define the DRLs. The results are compared to DRL data from the local, regional, and international levels. RESULT: The proposed DRLs using CTDI(vol) (mGy) are 53, 13, and 16 for the head, chest, and AP examinations respectively, while the DLP (mGy.cm) for the respective examinations were 1210, 635, and 822 mGy.cm. CONCLUSION: Baseline CT DRLs figures for the most frequently performed in Addis Ababa were provided. The discrepancies in dose between CT facilities and as well as between identical scanners suggests a large potential for dose optimization of examinations. This can be actually achieved through appropriate training of CT technologists and continuous dose audits. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12880-023-00963-1.
format Online
Article
Text
id pubmed-9830915
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98309152023-01-11 Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa Kumsa, Marema Jebessa Nguse, Teklehaimanot Mezgebe Ambessa, Haleluya Biredaw Gele, Tesfaye Tefera Fantaye, Wondemu Geteye Dellie, Seife Teferi BMC Med Imaging Research BACKGROUND: In medical imaging, a computed tomography (CT) scanner is a major source of ionizing radiation. All medical radiation exposures should be justified and optimized to meet the clinical diagnosis. Thus, to avoid unnecessary radiation doses for patients, diagnostic reference levels (DRLs) have been used. The DRLs are used to identify unusually high radiation doses during CT procedures, which are not appropriate for the clinical diagnosis. It has been successfully implemented in Europe, Canada, Australia, the United States, several industrialized countries, and a few underdeveloped countries. The present study aimed to establish DRLs for the head, chest, and abdominopelvic (AP) CT procedures in Addis Ababa, Ethiopia. METHODS: A pilot study identified the most frequent CT examinations in the city. At the time of the pilot, eighteen CT scan facilities were identified as having functioning CT scanners. Then, on nine CT facilities (50% of functional CT scanners), a prospective analysis of volume CT dose index (CTDI(vol)) and dose length product (DLP) was performed. We collected data for 838 adult patients’ head, chest, and AP CT examinations. SPSS version 25 was used to compute the median values of the DLP and CTDI(vol) dose indicators. The rounded 75th percentile of CTDI(vol) and DLP median values were used to define the DRLs. The results are compared to DRL data from the local, regional, and international levels. RESULT: The proposed DRLs using CTDI(vol) (mGy) are 53, 13, and 16 for the head, chest, and AP examinations respectively, while the DLP (mGy.cm) for the respective examinations were 1210, 635, and 822 mGy.cm. CONCLUSION: Baseline CT DRLs figures for the most frequently performed in Addis Ababa were provided. The discrepancies in dose between CT facilities and as well as between identical scanners suggests a large potential for dose optimization of examinations. This can be actually achieved through appropriate training of CT technologists and continuous dose audits. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12880-023-00963-1. BioMed Central 2023-01-09 /pmc/articles/PMC9830915/ /pubmed/36624411 http://dx.doi.org/10.1186/s12880-023-00963-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kumsa, Marema Jebessa
Nguse, Teklehaimanot Mezgebe
Ambessa, Haleluya Biredaw
Gele, Tesfaye Tefera
Fantaye, Wondemu Geteye
Dellie, Seife Teferi
Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa
title Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa
title_full Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa
title_fullStr Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa
title_full_unstemmed Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa
title_short Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa
title_sort establishment of local diagnostic reference levels for common adult ct examinations: a multicenter survey in addis ababa
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830915/
https://www.ncbi.nlm.nih.gov/pubmed/36624411
http://dx.doi.org/10.1186/s12880-023-00963-1
work_keys_str_mv AT kumsamaremajebessa establishmentoflocaldiagnosticreferencelevelsforcommonadultctexaminationsamulticentersurveyinaddisababa
AT nguseteklehaimanotmezgebe establishmentoflocaldiagnosticreferencelevelsforcommonadultctexaminationsamulticentersurveyinaddisababa
AT ambessahaleluyabiredaw establishmentoflocaldiagnosticreferencelevelsforcommonadultctexaminationsamulticentersurveyinaddisababa
AT geletesfayetefera establishmentoflocaldiagnosticreferencelevelsforcommonadultctexaminationsamulticentersurveyinaddisababa
AT fantayewondemugeteye establishmentoflocaldiagnosticreferencelevelsforcommonadultctexaminationsamulticentersurveyinaddisababa
AT dellieseifeteferi establishmentoflocaldiagnosticreferencelevelsforcommonadultctexaminationsamulticentersurveyinaddisababa