Cargando…
Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature
INTRODUCTION: Bicondylar Hoffa fractures are extremely uncommon injuries and there have only been a very small number of cases documented in the literature. CASE REPORT: A 28-year-old male presented to emergency department with injury to right knee and leg. X-ray was taken; however, they were not su...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9831222/ https://www.ncbi.nlm.nih.gov/pubmed/36687494 http://dx.doi.org/10.13107/jocr.2022.v12.i08.2972 |
_version_ | 1784867813397102592 |
---|---|
author | Alam, Noor Siddiqui, Yasir S Abbas, Mazhar Akshay, Varun |
author_facet | Alam, Noor Siddiqui, Yasir S Abbas, Mazhar Akshay, Varun |
author_sort | Alam, Noor |
collection | PubMed |
description | INTRODUCTION: Bicondylar Hoffa fractures are extremely uncommon injuries and there have only been a very small number of cases documented in the literature. CASE REPORT: A 28-year-old male presented to emergency department with injury to right knee and leg. X-ray was taken; however, they were not sufficient to determine the precise fracture pattern, so computed tomography scan was done for establishing diagnosis. Fracture managed successfully using compression screws and buttress plate with satisfactory result after a follow-up period of 1 year with ROM 20–120° with no signs of Avascular necrosis or arthritis and we also discussed the appropriate treatment options with supporting literatures. CONCLUSION: We conclude by describing a rare case of Bicondylar Hoffa fracture managed by open reduction and internal fixation with cancellous screws and Buttress plating. All cases of unicondylar Hoffa must be evaluated with a high index of suspicion to not miss the cases of Bicondylar Hoffa, which is extremely uncommon injury. |
format | Online Article Text |
id | pubmed-9831222 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-98312222023-01-19 Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature Alam, Noor Siddiqui, Yasir S Abbas, Mazhar Akshay, Varun J Orthop Case Rep Case Report INTRODUCTION: Bicondylar Hoffa fractures are extremely uncommon injuries and there have only been a very small number of cases documented in the literature. CASE REPORT: A 28-year-old male presented to emergency department with injury to right knee and leg. X-ray was taken; however, they were not sufficient to determine the precise fracture pattern, so computed tomography scan was done for establishing diagnosis. Fracture managed successfully using compression screws and buttress plate with satisfactory result after a follow-up period of 1 year with ROM 20–120° with no signs of Avascular necrosis or arthritis and we also discussed the appropriate treatment options with supporting literatures. CONCLUSION: We conclude by describing a rare case of Bicondylar Hoffa fracture managed by open reduction and internal fixation with cancellous screws and Buttress plating. All cases of unicondylar Hoffa must be evaluated with a high index of suspicion to not miss the cases of Bicondylar Hoffa, which is extremely uncommon injury. Indian Orthopaedic Research Group 2022-08 2022-08 /pmc/articles/PMC9831222/ /pubmed/36687494 http://dx.doi.org/10.13107/jocr.2022.v12.i08.2972 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Alam, Noor Siddiqui, Yasir S Abbas, Mazhar Akshay, Varun Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature |
title | Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature |
title_full | Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature |
title_fullStr | Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature |
title_full_unstemmed | Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature |
title_short | Buttress Plate Assisted Fixation for Bicondylar Hoffa Fracture: A Missed Fracture-case Report with Review of Literature |
title_sort | buttress plate assisted fixation for bicondylar hoffa fracture: a missed fracture-case report with review of literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9831222/ https://www.ncbi.nlm.nih.gov/pubmed/36687494 http://dx.doi.org/10.13107/jocr.2022.v12.i08.2972 |
work_keys_str_mv | AT alamnoor buttressplateassistedfixationforbicondylarhoffafractureamissedfracturecasereportwithreviewofliterature AT siddiquiyasirs buttressplateassistedfixationforbicondylarhoffafractureamissedfracturecasereportwithreviewofliterature AT abbasmazhar buttressplateassistedfixationforbicondylarhoffafractureamissedfracturecasereportwithreviewofliterature AT akshayvarun buttressplateassistedfixationforbicondylarhoffafractureamissedfracturecasereportwithreviewofliterature |