Cargando…

Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs

OBJECTIVE: To describe the use of a 100-millimeter marker placed on a stepped, fixed-height magnification marker stand to measure radiographic magnification on accuracy of implant size prediction when used for canine total hip replacement (THR) implant size selection. STUDY DESIGN: Retrospective stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Siemon, Heather K., Liska, William D., Israel, Sarah K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9831306/
https://www.ncbi.nlm.nih.gov/pubmed/36626397
http://dx.doi.org/10.1371/journal.pone.0280334
_version_ 1784867827390349312
author Siemon, Heather K.
Liska, William D.
Israel, Sarah K.
author_facet Siemon, Heather K.
Liska, William D.
Israel, Sarah K.
author_sort Siemon, Heather K.
collection PubMed
description OBJECTIVE: To describe the use of a 100-millimeter marker placed on a stepped, fixed-height magnification marker stand to measure radiographic magnification on accuracy of implant size prediction when used for canine total hip replacement (THR) implant size selection. STUDY DESIGN: Retrospective study. ANIMALS: Fifty-two hips in 45 dogs. METHODS: This study evaluated 52 consecutive canine total hip replacement surgery pre-planning procedures involving 45 dogs with 7 undergoing staged bilateral THRs. Data collected included demographic information, measured radiographic magnification for magnification recalibration, implant size prediction of the cups (52) and the stems (52) based on digital templates superimposed on digital radiographs, and the actual implant sizes used during surgery. RESULTS: Use of the magnification marker stand (MMS) and template application system resulted in an accurate prediction of implant size of 98/104 implants (94.2%) implants. CONCLUSION: A 100-mm marker placed on a magnification marker stand was a viable method to measure and recalibrate for magnification on digital radiographs during the template process to predict the THR implant sizes that should be available when the surgery begins. CLINICAL SIGNIFICANCE: This stepped calibration marker stand is helpful in determination of an accurate preoperative THR implant size prediction, lowering implant stock thresholds, operating time, and associated complications. Additionally, the radiographic documentation of the marker’s step height allows for indefinite confirmation of the magnification marker height used and for accurate repeatability for all follow-up imaging examinations and contralateral procedure planning.
format Online
Article
Text
id pubmed-9831306
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-98313062023-01-11 Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs Siemon, Heather K. Liska, William D. Israel, Sarah K. PLoS One Research Article OBJECTIVE: To describe the use of a 100-millimeter marker placed on a stepped, fixed-height magnification marker stand to measure radiographic magnification on accuracy of implant size prediction when used for canine total hip replacement (THR) implant size selection. STUDY DESIGN: Retrospective study. ANIMALS: Fifty-two hips in 45 dogs. METHODS: This study evaluated 52 consecutive canine total hip replacement surgery pre-planning procedures involving 45 dogs with 7 undergoing staged bilateral THRs. Data collected included demographic information, measured radiographic magnification for magnification recalibration, implant size prediction of the cups (52) and the stems (52) based on digital templates superimposed on digital radiographs, and the actual implant sizes used during surgery. RESULTS: Use of the magnification marker stand (MMS) and template application system resulted in an accurate prediction of implant size of 98/104 implants (94.2%) implants. CONCLUSION: A 100-mm marker placed on a magnification marker stand was a viable method to measure and recalibrate for magnification on digital radiographs during the template process to predict the THR implant sizes that should be available when the surgery begins. CLINICAL SIGNIFICANCE: This stepped calibration marker stand is helpful in determination of an accurate preoperative THR implant size prediction, lowering implant stock thresholds, operating time, and associated complications. Additionally, the radiographic documentation of the marker’s step height allows for indefinite confirmation of the magnification marker height used and for accurate repeatability for all follow-up imaging examinations and contralateral procedure planning. Public Library of Science 2023-01-10 /pmc/articles/PMC9831306/ /pubmed/36626397 http://dx.doi.org/10.1371/journal.pone.0280334 Text en © 2023 Siemon et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Siemon, Heather K.
Liska, William D.
Israel, Sarah K.
Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
title Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
title_full Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
title_fullStr Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
title_full_unstemmed Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
title_short Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
title_sort evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in dogs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9831306/
https://www.ncbi.nlm.nih.gov/pubmed/36626397
http://dx.doi.org/10.1371/journal.pone.0280334
work_keys_str_mv AT siemonheatherk evaluationofasteppedfixedheightmagnificationmarkerstandforusewitha100mmmarkerinimplantsizingpredictionin52totalhipreplacementproceduresindogs
AT liskawilliamd evaluationofasteppedfixedheightmagnificationmarkerstandforusewitha100mmmarkerinimplantsizingpredictionin52totalhipreplacementproceduresindogs
AT israelsarahk evaluationofasteppedfixedheightmagnificationmarkerstandforusewitha100mmmarkerinimplantsizingpredictionin52totalhipreplacementproceduresindogs