Cargando…

Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly

BACKGROUND: Percutaneous kyphoplasty (PKP) has been demonstrated to be effective in the treatment of osteoporotic vertebral compression fractures (OVCF). However, bilateral puncture techniques take more time to accept more X-ray radiation; some spinal surgeons apply unilateral puncture PKP, but the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Xiaoji, Liu, Yongtao, Cao, Xiaojian, Jin, Genyang, Li, Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9832637/
https://www.ncbi.nlm.nih.gov/pubmed/36631874
http://dx.doi.org/10.1186/s13018-023-03506-0
_version_ 1784868094065246208
author Zhou, Xiaoji
Liu, Yongtao
Cao, Xiaojian
Jin, Genyang
Li, Hong
author_facet Zhou, Xiaoji
Liu, Yongtao
Cao, Xiaojian
Jin, Genyang
Li, Hong
author_sort Zhou, Xiaoji
collection PubMed
description BACKGROUND: Percutaneous kyphoplasty (PKP) has been demonstrated to be effective in the treatment of osteoporotic vertebral compression fractures (OVCF). However, bilateral puncture techniques take more time to accept more X-ray radiation; some spinal surgeons apply unilateral puncture PKP, but the cement cannot be symmetrically distributed in the vertebral body, so we apply a directional bone cement delivery device that undergoes PKP through the unilateral pedicle puncture. This research aims to compare the clinical and radiological results of PKP via unilateral pedicle approach using a traditional bone cement delivery device and a directional bone cement delivery device and determine the value of a directional delivery device for the therapy of thoracolumbar compression fracture in the elderly. METHODS: We undertook a retrospective analysis of patients with single-level OVCF treated with unilateral pedicle puncture PKP from Jan 2018 to Jan 2020. Operation time, radiation exposure, bone cement injection volume, and the incidence of bone cement leakage were recorded for presentation, and the cement leakage and bone cement distribution were measured by X-ray and computed tomography scan. The patients were followed up postoperatively and were assessed mainly with regard to clinical and radiological outcomes. RESULTS: There was no significant difference in the operation time, radiation exposure time, and incidence of bone cement leakage between the two groups. A significant difference was observed in the volume of bone cement injection between the two groups. All patients in both groups had significantly less pain after the procedures, compared with their preoperative period pain. There were no significant differences in Visual Analogue Scale, the relative height of the vertebral body, Cobb angle, and Quality of Life Questionnaire of the European Foundation for Osteoporosis between the two groups at 1 week after PKP, significant difference was observed only 12 months after operation. CONCLUSION: Application of directional bone cement delivery device is safe and feasible, compared with the application of traditional bone cement delivery device, without prolonging the operative time, radiation exposure time, and the incidence of bone cement leakage. It has the advantages of good short- and medium-term effect, excellent bone cement distribution, and low incidence of kyphosis recurrence.
format Online
Article
Text
id pubmed-9832637
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98326372023-01-12 Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly Zhou, Xiaoji Liu, Yongtao Cao, Xiaojian Jin, Genyang Li, Hong J Orthop Surg Res Research Article BACKGROUND: Percutaneous kyphoplasty (PKP) has been demonstrated to be effective in the treatment of osteoporotic vertebral compression fractures (OVCF). However, bilateral puncture techniques take more time to accept more X-ray radiation; some spinal surgeons apply unilateral puncture PKP, but the cement cannot be symmetrically distributed in the vertebral body, so we apply a directional bone cement delivery device that undergoes PKP through the unilateral pedicle puncture. This research aims to compare the clinical and radiological results of PKP via unilateral pedicle approach using a traditional bone cement delivery device and a directional bone cement delivery device and determine the value of a directional delivery device for the therapy of thoracolumbar compression fracture in the elderly. METHODS: We undertook a retrospective analysis of patients with single-level OVCF treated with unilateral pedicle puncture PKP from Jan 2018 to Jan 2020. Operation time, radiation exposure, bone cement injection volume, and the incidence of bone cement leakage were recorded for presentation, and the cement leakage and bone cement distribution were measured by X-ray and computed tomography scan. The patients were followed up postoperatively and were assessed mainly with regard to clinical and radiological outcomes. RESULTS: There was no significant difference in the operation time, radiation exposure time, and incidence of bone cement leakage between the two groups. A significant difference was observed in the volume of bone cement injection between the two groups. All patients in both groups had significantly less pain after the procedures, compared with their preoperative period pain. There were no significant differences in Visual Analogue Scale, the relative height of the vertebral body, Cobb angle, and Quality of Life Questionnaire of the European Foundation for Osteoporosis between the two groups at 1 week after PKP, significant difference was observed only 12 months after operation. CONCLUSION: Application of directional bone cement delivery device is safe and feasible, compared with the application of traditional bone cement delivery device, without prolonging the operative time, radiation exposure time, and the incidence of bone cement leakage. It has the advantages of good short- and medium-term effect, excellent bone cement distribution, and low incidence of kyphosis recurrence. BioMed Central 2023-01-11 /pmc/articles/PMC9832637/ /pubmed/36631874 http://dx.doi.org/10.1186/s13018-023-03506-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Zhou, Xiaoji
Liu, Yongtao
Cao, Xiaojian
Jin, Genyang
Li, Hong
Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
title Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
title_full Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
title_fullStr Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
title_full_unstemmed Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
title_short Comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
title_sort comparison of a directional cement delivery device versus conventional device in unilateral percutaneous kyphoplasty for the therapy of osteoporotic thoracolumbar fracture in the elderly
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9832637/
https://www.ncbi.nlm.nih.gov/pubmed/36631874
http://dx.doi.org/10.1186/s13018-023-03506-0
work_keys_str_mv AT zhouxiaoji comparisonofadirectionalcementdeliverydeviceversusconventionaldeviceinunilateralpercutaneouskyphoplastyforthetherapyofosteoporoticthoracolumbarfractureintheelderly
AT liuyongtao comparisonofadirectionalcementdeliverydeviceversusconventionaldeviceinunilateralpercutaneouskyphoplastyforthetherapyofosteoporoticthoracolumbarfractureintheelderly
AT caoxiaojian comparisonofadirectionalcementdeliverydeviceversusconventionaldeviceinunilateralpercutaneouskyphoplastyforthetherapyofosteoporoticthoracolumbarfractureintheelderly
AT jingenyang comparisonofadirectionalcementdeliverydeviceversusconventionaldeviceinunilateralpercutaneouskyphoplastyforthetherapyofosteoporoticthoracolumbarfractureintheelderly
AT lihong comparisonofadirectionalcementdeliverydeviceversusconventionaldeviceinunilateralpercutaneouskyphoplastyforthetherapyofosteoporoticthoracolumbarfractureintheelderly