Cargando…

Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study

BACKGROUND: Differences between programmed capsulorhexis diameter and actual resulting capsulorhexis diameter (ARCD) are commonly encountered in femtosecond laser-assisted cataract surgery (FLACS). The purpose of this study was to identify the preoperative ophthalmic variables influencing capsulorhe...

Descripción completa

Detalles Bibliográficos
Autores principales: Akaishi, Miki, Teshigawara, Takeshi, Hata, Seiichiro, Meguro, Akira, Mizuki, Nobuhisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9832795/
https://www.ncbi.nlm.nih.gov/pubmed/36631785
http://dx.doi.org/10.1186/s12886-023-02776-w
_version_ 1784868127695175680
author Akaishi, Miki
Teshigawara, Takeshi
Hata, Seiichiro
Meguro, Akira
Mizuki, Nobuhisa
author_facet Akaishi, Miki
Teshigawara, Takeshi
Hata, Seiichiro
Meguro, Akira
Mizuki, Nobuhisa
author_sort Akaishi, Miki
collection PubMed
description BACKGROUND: Differences between programmed capsulorhexis diameter and actual resulting capsulorhexis diameter (ARCD) are commonly encountered in femtosecond laser-assisted cataract surgery (FLACS). The purpose of this study was to identify the preoperative ophthalmic variables influencing capsulorhexis diameter index (CDI) in FLACS for adults and create a multiple linear regression model for obtaining a more accurate capsulorhexis diameter. METHODS: This retrospective study involved sixty-seven eyes of 44 patients who received FLACS and intraocular lens implantation. The ARCD was measured using anterior segment swept-source optical coherence tomography (CASIA 2). Keratometry (K1, K2 and average K), anterior chamber depth (ACD), lens thickness (LT), anterior chamber width (ACW), white-to-white (WTW), curvature radius of anterior lens capsule (Front R) and axial length (AL) were all measured preoperatively. Based on the derived data, LT/ACW, LT/AL, LT/ACD and LT/ACW/Front R were calculated. The ratio of the programmed capsulorhexis diameter and ARCD was defined as the CDI. Correlation analysis was conducted to examine the relationship between preoperative variables listed above and the CDI. Multiple linear regression analysis was applied to select the most influential preoperative variables on CDI. RESULTS: ACD, LT, ACW, Front R, AL, LT/ACW, LT/AL, LT/ACD, and LT/ACW/Front R showed significant correlation with CDI. Front R and LT/ACW/Front R were selected as constants in the multiple linear regression model using stepwise variable selection. The following equation represents the multiple linear regression model: CDI = 1.306–4.516 × LT/ACW/FrontR-0.011 × Front R, when P < 0.0001, adjusted R-squared = 0.919, variance inflation factor = 8.389, and Durbin-Watson ratio = 1.846. Predicted postoperative capsulorhexis diameter (PPCD) equation was created based on CDI equation as follows: PPCD = programmed capsulorhexis diameter × 1.306–4.516 × LT/ACW/FrontR-0.011 × Front R. CONCLUSION: Front R and LT/ACW/Front R were found to be the most significant influencing factors of capsulorhexis size. CDI and PPCD calculation equations presented in this study may be useful in setting up more accurate programmed capsulorhexis diameter for FLACS in adults, resulting in a precise ARCD.
format Online
Article
Text
id pubmed-9832795
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98327952023-01-12 Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study Akaishi, Miki Teshigawara, Takeshi Hata, Seiichiro Meguro, Akira Mizuki, Nobuhisa BMC Ophthalmol Research BACKGROUND: Differences between programmed capsulorhexis diameter and actual resulting capsulorhexis diameter (ARCD) are commonly encountered in femtosecond laser-assisted cataract surgery (FLACS). The purpose of this study was to identify the preoperative ophthalmic variables influencing capsulorhexis diameter index (CDI) in FLACS for adults and create a multiple linear regression model for obtaining a more accurate capsulorhexis diameter. METHODS: This retrospective study involved sixty-seven eyes of 44 patients who received FLACS and intraocular lens implantation. The ARCD was measured using anterior segment swept-source optical coherence tomography (CASIA 2). Keratometry (K1, K2 and average K), anterior chamber depth (ACD), lens thickness (LT), anterior chamber width (ACW), white-to-white (WTW), curvature radius of anterior lens capsule (Front R) and axial length (AL) were all measured preoperatively. Based on the derived data, LT/ACW, LT/AL, LT/ACD and LT/ACW/Front R were calculated. The ratio of the programmed capsulorhexis diameter and ARCD was defined as the CDI. Correlation analysis was conducted to examine the relationship between preoperative variables listed above and the CDI. Multiple linear regression analysis was applied to select the most influential preoperative variables on CDI. RESULTS: ACD, LT, ACW, Front R, AL, LT/ACW, LT/AL, LT/ACD, and LT/ACW/Front R showed significant correlation with CDI. Front R and LT/ACW/Front R were selected as constants in the multiple linear regression model using stepwise variable selection. The following equation represents the multiple linear regression model: CDI = 1.306–4.516 × LT/ACW/FrontR-0.011 × Front R, when P < 0.0001, adjusted R-squared = 0.919, variance inflation factor = 8.389, and Durbin-Watson ratio = 1.846. Predicted postoperative capsulorhexis diameter (PPCD) equation was created based on CDI equation as follows: PPCD = programmed capsulorhexis diameter × 1.306–4.516 × LT/ACW/FrontR-0.011 × Front R. CONCLUSION: Front R and LT/ACW/Front R were found to be the most significant influencing factors of capsulorhexis size. CDI and PPCD calculation equations presented in this study may be useful in setting up more accurate programmed capsulorhexis diameter for FLACS in adults, resulting in a precise ARCD. BioMed Central 2023-01-11 /pmc/articles/PMC9832795/ /pubmed/36631785 http://dx.doi.org/10.1186/s12886-023-02776-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Akaishi, Miki
Teshigawara, Takeshi
Hata, Seiichiro
Meguro, Akira
Mizuki, Nobuhisa
Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
title Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
title_full Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
title_fullStr Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
title_full_unstemmed Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
title_short Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
title_sort multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9832795/
https://www.ncbi.nlm.nih.gov/pubmed/36631785
http://dx.doi.org/10.1186/s12886-023-02776-w
work_keys_str_mv AT akaishimiki multiplelinearregressionmodelforimprovingaccuracyofcapsulorhexissizecalculationinfemtosecondlaserassistedcataractsurgeryforadultsaretrospectivesinglecenterstudy
AT teshigawaratakeshi multiplelinearregressionmodelforimprovingaccuracyofcapsulorhexissizecalculationinfemtosecondlaserassistedcataractsurgeryforadultsaretrospectivesinglecenterstudy
AT hataseiichiro multiplelinearregressionmodelforimprovingaccuracyofcapsulorhexissizecalculationinfemtosecondlaserassistedcataractsurgeryforadultsaretrospectivesinglecenterstudy
AT meguroakira multiplelinearregressionmodelforimprovingaccuracyofcapsulorhexissizecalculationinfemtosecondlaserassistedcataractsurgeryforadultsaretrospectivesinglecenterstudy
AT mizukinobuhisa multiplelinearregressionmodelforimprovingaccuracyofcapsulorhexissizecalculationinfemtosecondlaserassistedcataractsurgeryforadultsaretrospectivesinglecenterstudy