Cargando…
iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre
Purpose: To investigate whether the inter-observer variation is similar between the Goldmann applanation tonometer used by healthcare staff and the iCare® Home tonometer used by glaucoma patients, volunteers and healthcare staff. Methods: Sixty-one participants were recruited to the study, including...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834317/ https://www.ncbi.nlm.nih.gov/pubmed/35505614 http://dx.doi.org/10.1177/11206721221099252 |
_version_ | 1784868435594838016 |
---|---|
author | Quérat, Laurence Chen, Enping |
author_facet | Quérat, Laurence Chen, Enping |
author_sort | Quérat, Laurence |
collection | PubMed |
description | Purpose: To investigate whether the inter-observer variation is similar between the Goldmann applanation tonometer used by healthcare staff and the iCare® Home tonometer used by glaucoma patients, volunteers and healthcare staff. Methods: Sixty-one participants were recruited to the study, including 24 glaucoma patients. Seven participants were excluded. For each participant, intraocular pressure (IOP) was measured on the same occasion by two different healthcare staff using GAT as well as by a healthcare staff and the participant using the iCare® Home tonometer. Results: Seventy-two per cent of iCare® measurements were within 3 mmHg of the GAT measurements. There was a statistically significant difference between the trainers’ measurements made with iCare® Home and those made with GAT (p < 0.001), as well as between the GAT measurements made by trainers and those made by extra personnel (p = 0.017). The strongest correlation was between iCare® Home participants’ and trainers’ measurements (0.934). The correlation between different users with GAT was lower (0.769). The inter-user agreement was excellent for iCare® Home users (95% CI 0.93, ranging from 0.880 to 0.959) and moderate for GAT users (95% CI 0.741, ranging from 0.558 to 0.849). Conclusion: Our study found that tonometry with iCare® Home has similar or less inter-user variation compared with GAT. |
format | Online Article Text |
id | pubmed-9834317 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-98343172023-01-13 iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre Quérat, Laurence Chen, Enping Eur J Ophthalmol Original Research Articles Purpose: To investigate whether the inter-observer variation is similar between the Goldmann applanation tonometer used by healthcare staff and the iCare® Home tonometer used by glaucoma patients, volunteers and healthcare staff. Methods: Sixty-one participants were recruited to the study, including 24 glaucoma patients. Seven participants were excluded. For each participant, intraocular pressure (IOP) was measured on the same occasion by two different healthcare staff using GAT as well as by a healthcare staff and the participant using the iCare® Home tonometer. Results: Seventy-two per cent of iCare® measurements were within 3 mmHg of the GAT measurements. There was a statistically significant difference between the trainers’ measurements made with iCare® Home and those made with GAT (p < 0.001), as well as between the GAT measurements made by trainers and those made by extra personnel (p = 0.017). The strongest correlation was between iCare® Home participants’ and trainers’ measurements (0.934). The correlation between different users with GAT was lower (0.769). The inter-user agreement was excellent for iCare® Home users (95% CI 0.93, ranging from 0.880 to 0.959) and moderate for GAT users (95% CI 0.741, ranging from 0.558 to 0.849). Conclusion: Our study found that tonometry with iCare® Home has similar or less inter-user variation compared with GAT. SAGE Publications 2022-05-03 2023-01 /pmc/articles/PMC9834317/ /pubmed/35505614 http://dx.doi.org/10.1177/11206721221099252 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Articles Quérat, Laurence Chen, Enping iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
title | iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
title_full | iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
title_fullStr | iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
title_full_unstemmed | iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
title_short | iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
title_sort | icare® home vs goldmann applanation tonometry: agreement of methods and comparison of inter-observer variation at a tertiary eye centre |
topic | Original Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834317/ https://www.ncbi.nlm.nih.gov/pubmed/35505614 http://dx.doi.org/10.1177/11206721221099252 |
work_keys_str_mv | AT queratlaurence icarehomevsgoldmannapplanationtonometryagreementofmethodsandcomparisonofinterobservervariationatatertiaryeyecentre AT chenenping icarehomevsgoldmannapplanationtonometryagreementofmethodsandcomparisonofinterobservervariationatatertiaryeyecentre |