Cargando…
Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis
BACKGROUND: Cardiovascular disease is the most common cause of death after kidney transplantation. Coronary artery disease (CAD) assessment is therefore mandatory in patients evaluated for transplantation. We aimed to assess the diagnostic accuracy for CAD of single-photon emission computed tomograp...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834355/ https://www.ncbi.nlm.nih.gov/pubmed/33948891 http://dx.doi.org/10.1007/s12350-021-02621-x |
_version_ | 1784868443935211520 |
---|---|
author | Kelderman, Jeroen R. Jolink, Floris E. J. Benjamens, Stan Monroy-Gonzalez, Andrea G. Pol, Robert A. Slart, Riemer H. J. A. |
author_facet | Kelderman, Jeroen R. Jolink, Floris E. J. Benjamens, Stan Monroy-Gonzalez, Andrea G. Pol, Robert A. Slart, Riemer H. J. A. |
author_sort | Kelderman, Jeroen R. |
collection | PubMed |
description | BACKGROUND: Cardiovascular disease is the most common cause of death after kidney transplantation. Coronary artery disease (CAD) assessment is therefore mandatory in patients evaluated for transplantation. We aimed to assess the diagnostic accuracy for CAD of single-photon emission computed tomography (SPECT) compared to the standards invasive coronary angiography (ICA) and coronary computed tomography angiography (CCTA) in patients evaluated for kidney transplantation. METHODS: We performed a systematic literature search in PubMed, EMBASE, Web of Science, OvidSP (Medline), The Cochrane Library and Google Scholar. Studies investigating the diagnostic accuracy of myocardial perfusion imaging (MPI) SPECT in patients evaluated for kidney transplantation were retrieved. After a risk of bias assessment using QUADAS-2, a meta-analysis was conducted. RESULTS: Out of 1459 records, 13 MPI SPECT studies were included in the meta-analysis with a total of 1245 MPI SPECT scans. There were no studies available with CCTA as reference. Pooled sensitivity of MPI SPECT for CAD was 0.66 (95% CI 0.53 to 0.77), pooled specificity was 0.75 (95% CI 0.63 to 0.84) and the area under the curve (AUC) was 0.76. Positive likelihood ratio was 2.50 (95% CI 1.78 to 3.51) and negative likelihood ratio was 0.41 (95% CI 0.28 to 0.61). Pooled positive predictive value was 64.9% and pooled negative predictive value was 74.1%. Significant heterogeneity existed across the included studies. CONCLUSIONS: MPI SPECT had a moderate diagnostic accuracy in patients evaluated for kidney transplantation, with a high rate of false-negative findings. The use of an anatomical gold standard against a functional imaging test in the included studies is however suboptimal. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-021-02621-x. |
format | Online Article Text |
id | pubmed-9834355 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-98343552023-01-13 Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis Kelderman, Jeroen R. Jolink, Floris E. J. Benjamens, Stan Monroy-Gonzalez, Andrea G. Pol, Robert A. Slart, Riemer H. J. A. J Nucl Cardiol Review Article BACKGROUND: Cardiovascular disease is the most common cause of death after kidney transplantation. Coronary artery disease (CAD) assessment is therefore mandatory in patients evaluated for transplantation. We aimed to assess the diagnostic accuracy for CAD of single-photon emission computed tomography (SPECT) compared to the standards invasive coronary angiography (ICA) and coronary computed tomography angiography (CCTA) in patients evaluated for kidney transplantation. METHODS: We performed a systematic literature search in PubMed, EMBASE, Web of Science, OvidSP (Medline), The Cochrane Library and Google Scholar. Studies investigating the diagnostic accuracy of myocardial perfusion imaging (MPI) SPECT in patients evaluated for kidney transplantation were retrieved. After a risk of bias assessment using QUADAS-2, a meta-analysis was conducted. RESULTS: Out of 1459 records, 13 MPI SPECT studies were included in the meta-analysis with a total of 1245 MPI SPECT scans. There were no studies available with CCTA as reference. Pooled sensitivity of MPI SPECT for CAD was 0.66 (95% CI 0.53 to 0.77), pooled specificity was 0.75 (95% CI 0.63 to 0.84) and the area under the curve (AUC) was 0.76. Positive likelihood ratio was 2.50 (95% CI 1.78 to 3.51) and negative likelihood ratio was 0.41 (95% CI 0.28 to 0.61). Pooled positive predictive value was 64.9% and pooled negative predictive value was 74.1%. Significant heterogeneity existed across the included studies. CONCLUSIONS: MPI SPECT had a moderate diagnostic accuracy in patients evaluated for kidney transplantation, with a high rate of false-negative findings. The use of an anatomical gold standard against a functional imaging test in the included studies is however suboptimal. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-021-02621-x. Springer International Publishing 2021-05-04 2022 /pmc/articles/PMC9834355/ /pubmed/33948891 http://dx.doi.org/10.1007/s12350-021-02621-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Review Article Kelderman, Jeroen R. Jolink, Floris E. J. Benjamens, Stan Monroy-Gonzalez, Andrea G. Pol, Robert A. Slart, Riemer H. J. A. Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis |
title | Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis |
title_full | Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis |
title_fullStr | Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis |
title_full_unstemmed | Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis |
title_short | Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis |
title_sort | diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: a systematic review and meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834355/ https://www.ncbi.nlm.nih.gov/pubmed/33948891 http://dx.doi.org/10.1007/s12350-021-02621-x |
work_keys_str_mv | AT keldermanjeroenr diagnosticaccuracyofmyocardialperfusionimaginginpatientsevaluatedforkidneytransplantationasystematicreviewandmetaanalysis AT jolinkflorisej diagnosticaccuracyofmyocardialperfusionimaginginpatientsevaluatedforkidneytransplantationasystematicreviewandmetaanalysis AT benjamensstan diagnosticaccuracyofmyocardialperfusionimaginginpatientsevaluatedforkidneytransplantationasystematicreviewandmetaanalysis AT monroygonzalezandreag diagnosticaccuracyofmyocardialperfusionimaginginpatientsevaluatedforkidneytransplantationasystematicreviewandmetaanalysis AT polroberta diagnosticaccuracyofmyocardialperfusionimaginginpatientsevaluatedforkidneytransplantationasystematicreviewandmetaanalysis AT slartriemerhja diagnosticaccuracyofmyocardialperfusionimaginginpatientsevaluatedforkidneytransplantationasystematicreviewandmetaanalysis |