Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole

INTRODUCTION: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time. METHODS: This retrospective study enrolled 169 myopic eyes from 169 pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Boliang, Chen, Xun, Cheng, Mingrui, Lei, Yadi, Jiang, Yinjie, Xu, Yilin, Wang, Xiaoying, Zhou, Xingtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834492/
https://www.ncbi.nlm.nih.gov/pubmed/36335511
http://dx.doi.org/10.1007/s40123-022-00606-8
_version_ 1784868471683678208
author Li, Boliang
Chen, Xun
Cheng, Mingrui
Lei, Yadi
Jiang, Yinjie
Xu, Yilin
Wang, Xiaoying
Zhou, Xingtao
author_facet Li, Boliang
Chen, Xun
Cheng, Mingrui
Lei, Yadi
Jiang, Yinjie
Xu, Yilin
Wang, Xiaoying
Zhou, Xingtao
author_sort Li, Boliang
collection PubMed
description INTRODUCTION: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time. METHODS: This retrospective study enrolled 169 myopic eyes from 169 patients (137 women and 32 men) who underwent ICL V4c implantation to correct myopia and astigmatism. Vault values were measured quantitatively using a rotating Scheimpflug camera. Each patient underwent at least four postoperative follow-up visits at 1 month, 6 months, 1 year, and more than 2 years. We compared postoperative values between groups and identified factors affecting vault changes over time. RESULTS: The mean vaults at 1 month (baseline), 6 months, 1 year, and the last follow-up time following ICL implantation were 540.83 ± 186.13, 520.00 ± 196.08, 503.79 ± 198.30, and 471.42 ± 211.35 μm, respectively. Eyes with baseline vaults of 250–750 and ≥ 750 μm exhibited a trend of vault decrease over time, and the differences were statistically significant (P < 0.05) at 6 months and 1 year postoperatively, respectively. The variables relevant to the value of vault decrease between baseline and last follow-up time were anterior chamber depth (ACD) and ICL power (adjusted R(2) = 0.121, P < 0.001). CONCLUSIONS: We found a trend of decreased mean objective vault values over time, which was more obvious in eyes with higher baseline vault values. The vault value of the ICL decreased more in eyes with shallower ACDs, higher ICL power, or both. Moreover, the decrease in vault values became statistically significant earlier in eyes with higher baseline vaults or shallower ACDs.
format Online
Article
Text
id pubmed-9834492
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-98344922023-01-13 Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole Li, Boliang Chen, Xun Cheng, Mingrui Lei, Yadi Jiang, Yinjie Xu, Yilin Wang, Xiaoying Zhou, Xingtao Ophthalmol Ther Original Research INTRODUCTION: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time. METHODS: This retrospective study enrolled 169 myopic eyes from 169 patients (137 women and 32 men) who underwent ICL V4c implantation to correct myopia and astigmatism. Vault values were measured quantitatively using a rotating Scheimpflug camera. Each patient underwent at least four postoperative follow-up visits at 1 month, 6 months, 1 year, and more than 2 years. We compared postoperative values between groups and identified factors affecting vault changes over time. RESULTS: The mean vaults at 1 month (baseline), 6 months, 1 year, and the last follow-up time following ICL implantation were 540.83 ± 186.13, 520.00 ± 196.08, 503.79 ± 198.30, and 471.42 ± 211.35 μm, respectively. Eyes with baseline vaults of 250–750 and ≥ 750 μm exhibited a trend of vault decrease over time, and the differences were statistically significant (P < 0.05) at 6 months and 1 year postoperatively, respectively. The variables relevant to the value of vault decrease between baseline and last follow-up time were anterior chamber depth (ACD) and ICL power (adjusted R(2) = 0.121, P < 0.001). CONCLUSIONS: We found a trend of decreased mean objective vault values over time, which was more obvious in eyes with higher baseline vault values. The vault value of the ICL decreased more in eyes with shallower ACDs, higher ICL power, or both. Moreover, the decrease in vault values became statistically significant earlier in eyes with higher baseline vaults or shallower ACDs. Springer Healthcare 2022-11-06 2023-02 /pmc/articles/PMC9834492/ /pubmed/36335511 http://dx.doi.org/10.1007/s40123-022-00606-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Original Research
Li, Boliang
Chen, Xun
Cheng, Mingrui
Lei, Yadi
Jiang, Yinjie
Xu, Yilin
Wang, Xiaoying
Zhou, Xingtao
Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
title Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
title_full Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
title_fullStr Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
title_full_unstemmed Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
title_short Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
title_sort long-term vault changes in different levels and factors affecting vault change after implantation of implantable collamer lens with a central hole
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834492/
https://www.ncbi.nlm.nih.gov/pubmed/36335511
http://dx.doi.org/10.1007/s40123-022-00606-8
work_keys_str_mv AT liboliang longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT chenxun longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT chengmingrui longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT leiyadi longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT jiangyinjie longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT xuyilin longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT wangxiaoying longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole
AT zhouxingtao longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole