Cargando…
Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole
INTRODUCTION: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time. METHODS: This retrospective study enrolled 169 myopic eyes from 169 pa...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Healthcare
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834492/ https://www.ncbi.nlm.nih.gov/pubmed/36335511 http://dx.doi.org/10.1007/s40123-022-00606-8 |
_version_ | 1784868471683678208 |
---|---|
author | Li, Boliang Chen, Xun Cheng, Mingrui Lei, Yadi Jiang, Yinjie Xu, Yilin Wang, Xiaoying Zhou, Xingtao |
author_facet | Li, Boliang Chen, Xun Cheng, Mingrui Lei, Yadi Jiang, Yinjie Xu, Yilin Wang, Xiaoying Zhou, Xingtao |
author_sort | Li, Boliang |
collection | PubMed |
description | INTRODUCTION: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time. METHODS: This retrospective study enrolled 169 myopic eyes from 169 patients (137 women and 32 men) who underwent ICL V4c implantation to correct myopia and astigmatism. Vault values were measured quantitatively using a rotating Scheimpflug camera. Each patient underwent at least four postoperative follow-up visits at 1 month, 6 months, 1 year, and more than 2 years. We compared postoperative values between groups and identified factors affecting vault changes over time. RESULTS: The mean vaults at 1 month (baseline), 6 months, 1 year, and the last follow-up time following ICL implantation were 540.83 ± 186.13, 520.00 ± 196.08, 503.79 ± 198.30, and 471.42 ± 211.35 μm, respectively. Eyes with baseline vaults of 250–750 and ≥ 750 μm exhibited a trend of vault decrease over time, and the differences were statistically significant (P < 0.05) at 6 months and 1 year postoperatively, respectively. The variables relevant to the value of vault decrease between baseline and last follow-up time were anterior chamber depth (ACD) and ICL power (adjusted R(2) = 0.121, P < 0.001). CONCLUSIONS: We found a trend of decreased mean objective vault values over time, which was more obvious in eyes with higher baseline vault values. The vault value of the ICL decreased more in eyes with shallower ACDs, higher ICL power, or both. Moreover, the decrease in vault values became statistically significant earlier in eyes with higher baseline vaults or shallower ACDs. |
format | Online Article Text |
id | pubmed-9834492 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-98344922023-01-13 Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole Li, Boliang Chen, Xun Cheng, Mingrui Lei, Yadi Jiang, Yinjie Xu, Yilin Wang, Xiaoying Zhou, Xingtao Ophthalmol Ther Original Research INTRODUCTION: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time. METHODS: This retrospective study enrolled 169 myopic eyes from 169 patients (137 women and 32 men) who underwent ICL V4c implantation to correct myopia and astigmatism. Vault values were measured quantitatively using a rotating Scheimpflug camera. Each patient underwent at least four postoperative follow-up visits at 1 month, 6 months, 1 year, and more than 2 years. We compared postoperative values between groups and identified factors affecting vault changes over time. RESULTS: The mean vaults at 1 month (baseline), 6 months, 1 year, and the last follow-up time following ICL implantation were 540.83 ± 186.13, 520.00 ± 196.08, 503.79 ± 198.30, and 471.42 ± 211.35 μm, respectively. Eyes with baseline vaults of 250–750 and ≥ 750 μm exhibited a trend of vault decrease over time, and the differences were statistically significant (P < 0.05) at 6 months and 1 year postoperatively, respectively. The variables relevant to the value of vault decrease between baseline and last follow-up time were anterior chamber depth (ACD) and ICL power (adjusted R(2) = 0.121, P < 0.001). CONCLUSIONS: We found a trend of decreased mean objective vault values over time, which was more obvious in eyes with higher baseline vault values. The vault value of the ICL decreased more in eyes with shallower ACDs, higher ICL power, or both. Moreover, the decrease in vault values became statistically significant earlier in eyes with higher baseline vaults or shallower ACDs. Springer Healthcare 2022-11-06 2023-02 /pmc/articles/PMC9834492/ /pubmed/36335511 http://dx.doi.org/10.1007/s40123-022-00606-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Original Research Li, Boliang Chen, Xun Cheng, Mingrui Lei, Yadi Jiang, Yinjie Xu, Yilin Wang, Xiaoying Zhou, Xingtao Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole |
title | Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole |
title_full | Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole |
title_fullStr | Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole |
title_full_unstemmed | Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole |
title_short | Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole |
title_sort | long-term vault changes in different levels and factors affecting vault change after implantation of implantable collamer lens with a central hole |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834492/ https://www.ncbi.nlm.nih.gov/pubmed/36335511 http://dx.doi.org/10.1007/s40123-022-00606-8 |
work_keys_str_mv | AT liboliang longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT chenxun longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT chengmingrui longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT leiyadi longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT jiangyinjie longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT xuyilin longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT wangxiaoying longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole AT zhouxingtao longtermvaultchangesindifferentlevelsandfactorsaffectingvaultchangeafterimplantationofimplantablecollamerlenswithacentralhole |