Cargando…
Evaluating the Utility of Temporal Compression in High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations
[Image: see text] Ion mobility spectrometry coupled to mass spectrometry (IMS-MS) is slowly becoming a more integral part in omics-based workflows. With the recent technological advancements in IMS-MS instrumentation, particularly those involving traveling wave-based separations, ultralong pathlengt...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9836067/ https://www.ncbi.nlm.nih.gov/pubmed/36785568 http://dx.doi.org/10.1021/acsmeasuresciau.2c00016 |
_version_ | 1784868785212096512 |
---|---|
author | Williamson, David L. Nagy, Gabe |
author_facet | Williamson, David L. Nagy, Gabe |
author_sort | Williamson, David L. |
collection | PubMed |
description | [Image: see text] Ion mobility spectrometry coupled to mass spectrometry (IMS-MS) is slowly becoming a more integral part in omics-based workflows. With the recent technological advancements in IMS-MS instrumentation, particularly those involving traveling wave-based separations, ultralong pathlengths have become readily available in commercial platforms (e.g., Select Series Cyclic IMS from Waters Corporation and MOBIE from MOBILion). However, a tradeoff exists in such ultralong pathlength separations: increasing peak-to-peak resolution at the cost of lower signal intensities and thus poorer sensitivity of measurements. Herein, we explore the utility of temporal compression, where ions are compressed in the time domain, following high-resolution cyclic ion mobility spectrometry-mass spectrometry-based separations on a commercially available, unmodified platform. We assessed temporal compression in the context of various separations including those of reverse sequence peptide isomers, chiral noncovalent complexes, and isotopologues. From our results, we demonstrated that temporal compression improves IMS peak intensities by up to a factor of 4 while only losing ∼5 to 10% of peak-to-peak resolution. Additionally, the improvement in peak quality and signal-to-noise ratio was evident when comparing IMS-MS separations with and without a temporal compression step performed. Temporal compression can readily be implemented in existing traveling wave-based IMS-MS platforms, and our initial proof-of-concept demonstration shows its promise as a tool for improving peak shapes and peak intensities without sacrificing losses in resolution. |
format | Online Article Text |
id | pubmed-9836067 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-98360672023-02-10 Evaluating the Utility of Temporal Compression in High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations Williamson, David L. Nagy, Gabe ACS Meas Sci Au [Image: see text] Ion mobility spectrometry coupled to mass spectrometry (IMS-MS) is slowly becoming a more integral part in omics-based workflows. With the recent technological advancements in IMS-MS instrumentation, particularly those involving traveling wave-based separations, ultralong pathlengths have become readily available in commercial platforms (e.g., Select Series Cyclic IMS from Waters Corporation and MOBIE from MOBILion). However, a tradeoff exists in such ultralong pathlength separations: increasing peak-to-peak resolution at the cost of lower signal intensities and thus poorer sensitivity of measurements. Herein, we explore the utility of temporal compression, where ions are compressed in the time domain, following high-resolution cyclic ion mobility spectrometry-mass spectrometry-based separations on a commercially available, unmodified platform. We assessed temporal compression in the context of various separations including those of reverse sequence peptide isomers, chiral noncovalent complexes, and isotopologues. From our results, we demonstrated that temporal compression improves IMS peak intensities by up to a factor of 4 while only losing ∼5 to 10% of peak-to-peak resolution. Additionally, the improvement in peak quality and signal-to-noise ratio was evident when comparing IMS-MS separations with and without a temporal compression step performed. Temporal compression can readily be implemented in existing traveling wave-based IMS-MS platforms, and our initial proof-of-concept demonstration shows its promise as a tool for improving peak shapes and peak intensities without sacrificing losses in resolution. American Chemical Society 2022-06-07 /pmc/articles/PMC9836067/ /pubmed/36785568 http://dx.doi.org/10.1021/acsmeasuresciau.2c00016 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Williamson, David L. Nagy, Gabe Evaluating the Utility of Temporal Compression in High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations |
title | Evaluating the Utility of Temporal Compression in
High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations |
title_full | Evaluating the Utility of Temporal Compression in
High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations |
title_fullStr | Evaluating the Utility of Temporal Compression in
High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations |
title_full_unstemmed | Evaluating the Utility of Temporal Compression in
High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations |
title_short | Evaluating the Utility of Temporal Compression in
High-Resolution Traveling Wave-Based Cyclic Ion Mobility Separations |
title_sort | evaluating the utility of temporal compression in
high-resolution traveling wave-based cyclic ion mobility separations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9836067/ https://www.ncbi.nlm.nih.gov/pubmed/36785568 http://dx.doi.org/10.1021/acsmeasuresciau.2c00016 |
work_keys_str_mv | AT williamsondavidl evaluatingtheutilityoftemporalcompressioninhighresolutiontravelingwavebasedcyclicionmobilityseparations AT nagygabe evaluatingtheutilityoftemporalcompressioninhighresolutiontravelingwavebasedcyclicionmobilityseparations |